Copyright
©
2010 SMC Networks
3
e
g
a
P
All Rights Reserved
I/M SMCMT01-Z rev. 1.0
9/1/10
continued on next page
SMCMT01-Z Motion Sensor Quick Start Guide
C.
Insert a small flat-head screwdriver between the tabs at
the bottom of the SMCMT01-Z and turn the screwdriver
to push the tabs apart.
D.
Select the appropriate knockout mounting holes on the
mounting bracket for corner or flat-wall mounting.
Note:
Holes near the tamper actuator are not mounting
knockouts.
E.
Use screws and wall anchors, if necessary, to attach the
mounting bracket to the wall. Do not over tighten.
F.
Snap the SMCMT01-Z to the mounting bracket.
7
Pet Alley Application
To create a detection-free area close to the floor:
A.
Mount the SMCMT01-Z 3 feet (0.9 m) above the floor,
upside down with the detector window facing toward the
ceiling.
B.
Confirm that the undercrawl mask is in place to reduce
ceiling exposure. Coverage distance is 25 feet in Bi-
curtain Mode. Pets can roam freely below the SMCMT01-
Z mounting height, without triggering alarms.
C.
If you will not use the mask as described here or in step
4, remove the mask completely.
8
Battery Life Expectancy
Typical battery life expectancy for the SMCMT01-Z is 3 years
when using three batteries. The SMCMT01-Z uses two-way
wireless communication to extend battery life.
The following situations can reduce battery life:
If a receiver is unplugged or not installed.
Note:
Transmitters continue to send supervision messages
until a receiver returns an acknowledgement.
After an hour, the transmitter only tries to send a
supervision message every 60 minutes.
Frequent transmissions, such as constant motion where
messages are sent every time the movement is detected.
To compensate for frequent motion, the SMCMT01-Z
automatically rests for three minutes after each
activation before any further motion can be detected.
When installed in extreme hot or cold environments.
The following situation can extend battery life:
Extend transmitter supervision time in panel
programming.
Infrequent transmission trips, such as a low traffic area
where messages are rarely sent.
9
Maintain the SMCMT01-Z
When installed and used properly, the SMCMT01-Z provides
years of service, with minimal maintenance. To ensure
proper operation:
Use the procedure in step 5 to walk test the SMCMT01-Z
at least once per year.
Clean the inside of the SMCMT01-Z with a soft-bristled
brush or compressed air.
Clean the cover with a water dampened cloth as needed
to keep it free of dust and dirt.
Always test the SMCMT01-Z after cleaning.
Congratulations! You have successfully installed the
SMCMT01-Z Motion Sensor.