background image

- 13 - 

 

SJ2000-OMM0001 

 

 

 

Connector Assembly for Manifolds (for Junction Common)

 

 

 

Using the connector assembly (for junction common) for solenoid 
valves  installed  in  the  manifold  reduces  the  labor  involved  in 
wiring  work  because  common  wiring  for  all  solenoid  valves  is 
integrated into a single wire.

 

 

Single solenoid                            Double solenoid,

    

3 position type, 4 position type 

SJ3000-46-SC-

 

SJ3000-46-DC-

 

 
 
 
 
 
 
 
 
                                                           

Lead wire length

 

 

For single solenoid: SJ3000-46-SC-

 

 
For double solenoid

 

 

For 3 position type : SJ3000-46-DC-

 

For 4 position type 

 

 

How to Order 

Indicate  the  part  no.  of  the  connector  assembly  for  the  manifold 
and solenoid valve.   
If the arrangement is complicated, please specify them by means 
of the manifold specification sheet. 
Note 1) Applications like connectors not wired to a valve is not possible. 
Note  2)  For  the  solenoid  valve,  please  designate  “No  connector 

(MOZ)” for the connector type. 

Note  3)  Connector  assembly  with  lead  wire  for  place  where  the 

signals  are  transmitted  to  the  common  wiring.  (Only  the 
valves  of  first  station  and/or  last  station  of  manifold  are 
compatible to connector with lead wire for common.) 

 

 

 

 

 

 
 
 
 
(Example) 

SS5J3-60-04U

 

-------  1set 

SJ3160N-5MOZ ----- 2sets 

SJ3260N-5MOZ ----- 2sets 

SJ3000-46-S ---------  1set (Connector assembly for single solenoid) 

SJ3000-46-SC ------- 1set (Connector assembly for single solenoid) 

(for junction common) 

SJ3000-46-DC ------- 2sets (Connector assembly for double solenoid) 

(for junction common) 

   

 

The asterisk denotes the symbol for assembly. Prefix it to the 

part nos. of the solenoid valve, etc. 

 

 

Wiring Instructions for Connector Assembly (for Junction Common) 

 

 

If  only  connector  assembly  (for  junction  common)  is  ordered, 
please wire according to the instructions in the diagram below. 
For details on socket mounting, please refer to “How to Use Plug 
Connector” on the back page 12. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wire connection instructions 
1. Strip 6.5 to 7.5 mm from the tip of the lead wire. 
2.  Loosen  the  terminal  screws  (slotted  screws)  of  the 

power  supply  terminal  connectors,  plug  the  core 
wire  of  the  lead  wire  into  the  square  holes  of  the 
connector,  tighten  terminal  screws  at  the  proper 
torque,  and  fasten  them  securely.  (Gently  pull  the 
lead wire and check that it is fastened.) 

Precautions 

-  To  remove the  power  supply  terminal connector,  pull it  upward 

as is. When mounting, push it in until it makes a snapping noise. 

- When connecting wire, be careful because using lead wire that 

is outside of compatible lead wire ranges, or that are tightened 
to  anything  other  than  the  proper  torque,  creates  a  risk  of 
defective contact and other problems. 

 

 

 

 

Connector Assembly Part No.(for Junction Common)

    

How to Wire to PC Wiring System Compliant Power Supply Terminal   

 

For junction common 

 

Connector assembly 
SJ3000-46-S 

Connector assembly 
(for junction common) 
SJ3000-46-SC 

Double solenoid 
SJ3260N-5MOZ 

Common wiring 

 

SJ2000/3000  Series 

Specific  Product  Precautions  6 

Be sure to read before handling.   

 

Common wiring 

Socket 

Insert the socket into the connector (N) 
of the neighboring solenoid valve 

Caution 

Caution 

Nil 

300 mm 

600 mm 

10 

1000 mm 

15 

1500 mm 

20 

2000 mm 

25 

2500 mm 

30 

3000 mm 

50 

5000 mm 

 

Caution 

 

Connector assembly 
(for junction common) 
SJ3000-46-DC 

Single solenoid 
SJ3160N-5MOZ 

Summary of Contents for SJ2000 Series

Page 1: ...Doc No SJ2000 OMM0001 4 Port Solenoid Valve PRODUCT NAME SJ2000 3000 Series MODEL Series ...

Page 2: ...s Safety Instructions 2 3 Precautions on Design Selection 4 5 Mounting 6 Piping 6 Wiring 6 Lubrication 6 Air Supply 7 Operating Environment 7 Maintenance 7 Specific Product Precautions 8 to 13 Troubleshooting 14 Remedy 15 1 ...

Page 3: ... its latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operation and maintenance of machines or equipment including our products must be performed by...

Page 4: ...placement parts Please consult your nearest sales branch For any failure or damage reported within the warranty period which is clearly our responsibility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product Prior to using SMC products please read and understa...

Page 5: ...witch valve and a vacuum release valve If a non vacuum valve is installed in the middle of piping system having a vacuum the vacuum condition will not be maintained Use a valve designed for use under vacuum condition 10 Double solenoid type When using the double solenoid type for the first time actuators may travel in an unexpected direction depending on the switching position of the valve Impleme...

Page 6: ...ossible to operate a valve in extreme temperature as low as 10o C Take appropriate measures to avoid freezing of drainage moisture etc in low temperature 6 Operation for air blowing When using a solenoid valve for air blowing use an external pilot type Use caution because the pressure drop caused by the air blowing can have an affect on the internal pilot type valve when the internal pilot type va...

Page 7: ...proximately 1 4 turn As a reference value tightening torque is 0 4 to 0 5 N m 2 M5 After tightening the fitting by hand use a wrench to tighten the fitting an additional approximately 1 6 to 1 4 turn As a reference value tightening torque is 1 to 1 5 N m Note If tightened excessively the thread of the product may break or the gasket may deform If tightened insufficiently the thread of the product ...

Page 8: ...e is direct contact with any of these 2 Do not use in an environment where flammable gas or explosive gas exists Usage may cause a fire or explosion The products do not have an explosion proof construction 3 Do not use in a place subject to heavy vibration and or shock 4 The valve should not be exposed to prolonged sunlight Use a protective cover 5 Remove any sources of excessive heat 6 If it is u...

Page 9: ... connected to a single solenoid a dual 3 port valve or a 3 position valve will actuate Electric circuit diagram with positive common and light surge voltage suppressor Please connect it together with the polarity of the electric wiring of the manifold Valves with built in back pressure check valve is to protect the back pressure inside a valve For this reason use caution the valves with external p...

Page 10: ...ng time is over 67 ms at 24 VDC When a power saving circuit is installed a diode to prevent reverse current is not available for 12 VDC spec Therefore use caution not to connect in reverse Be careful about the allowable voltage fluctuation since a voltage drop of about 0 5 V occurs due to a transistor Refer to the solenoid specifications of each valve for details Light Indication When equipped wit...

Page 11: ...secured at fewer than the specified number of locations warping or twisting may occur in the DIN rail and manifold causing trouble such as air leakage Fitting Assembly Replacement By replacing a valve s fitting assembly it is possible to change the port size of the 4 A 2 B 1 P and 3 5 E ports When replacing it pull out the fitting assembly after removing the clip with a flat heat screwdriver etc T...

Page 12: ... 1 The 4 A and 2 B ports use the KJ series so the tube can be removed by pressing on part of the release bush However for the 1 P and 3 5 E ports please press the release bush evenly as before Hold down part of the release bush with your finger or a similar tool as shown in the diagram and pull out in the direction by the arrow 2 Pull out the tube while holding down the release button so that it d...

Page 13: ...oks open and they are locked automatically Next confirm that they are locked by pulling lightly on the lead wires Detaching To detach a socket from a connector pull out the lead wire while pressing the socket s hook with a stick having a thin tip approx 1 mm If the socket is used again spread the hook outward Plug connector lead wires have a standard length of 300 mm however the following lengths ...

Page 14: ...solenoid valve etc Wiring Instructionsfor ConnectorAssembly for Junction Common If only connector assembly for junction common is ordered please wire according to the instructions in the diagram below For details on socket mounting please refer to How to Use Plug Connector on the back page 12 Wire connection instructions 1 Strip 6 5 to 7 5 mm from the tip of the lead wire 2 Loosen the terminal scr...

Page 15: ...hifted Foreign matter caught in air seat of pilot valve Excessive amount of lubricant Higher voltage or wrong coil used Faulty wiring Poor contact at contactor wire or connection part Blown fuse or disconnection lead wire Poor seal on actuator cylinders etc side Faulty operation Pilot valve is not operated Though pilot valve does shift but main valve will not shift or will be sluggish Disconnectio...

Page 16: ...n in this operation manual 3 Lubrication has been stopped intermediately or lubrication was suspended temporary 4 Water splashed directely 5 Strong impact was given 6 Alien substance such as drain and particle got into Drain or garbage invaded a valve Reduce the amount of lubricant to the degree that no oil splashes out of the air exhaust port E port Check voltage Replace valve pilot valve Protect...

Page 17: ...otokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2008 SMC Corporation All Rights Reserved ...

Reviews: