background image

 

 PSE550-TF2Z042EN 

Page 1 of 2 

 

Instruction Manual     

Low Differential Pressure Sensor

 

PSE550 

 
 
 
 
 
 
 
 

The intended use of the pressure sensor is to measure the pressure of 
fluids and provide an analogue output signal. 

1 Safety Instructions 

These safety instructions are intended to prevent hazardous situations 
and/or equipment damage. These instructions indicate the level of 
potential hazard with the labels of “Caution,” “Warning” or “Danger.” 
They are all important notes for safety and must be followed in addition 
to International  Standards (ISO/IEC)

 *1)

, and other safety regulations. 

*1) 

ISO 4414: Pneumatic fluid power - General rules relating to systems.  

 ISO 4413: Hydraulic fluid power - General rules relating to systems. 
 IEC 60204-1:   Safety of machinery -  Electrical equipment of 

machines. (Part 1: General requirements) 

 ISO 10218-1: Manipulating industrial robots –Safety, etc. 

  Refer to the  product catalogue, operation  manual and handling 

precautions for SMC products for additional information. 

  Keep this manual in a safe place for future reference. 

  To ensure safety of personnel and equipment the safety instructions 

in  this manual must be observed, along with other relevant safety 
practices. 

 

Caution 

Caution indicates a hazard with a low level of risk 
which, if not avoided, could result in minor or 
moderate injury. 

 

Warning 

Warning indicates a hazard with a medium level 
of risk which, if not avoided, could result in death 
or serious injury. 

 

Danger 

Danger indicates a hazard with a high level of risk 
which, if not avoided, will result in death or 
serious injury. 

 

Warning 

 

Ensure compliance with relevant safety laws and standards. 

All work must be carried out in a safe manner by a qualified person in 
compliance with applicable national regulations. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2 Specifications 

2.1  General Specifications 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

2.2  Cable Specification 

Cable details 

3 cores 

2 cores 

Wire cross section 

0.15 mm

2

 

Insulator O/D 

0.9 mm 

Sheath material 

Oil resistant heavy-duty vinyl chloride 

Sheath outside 
dimension 

2.7 x 3.2 mm 

Cable Length 

3 m 

2.3  Specification when combined with PSE300 monitor 

Setting pressure range 

Differential pressure range 

Rated pressure range 

0 to 2 kPa 

Set resolution 

0.01 kPa 

Switch 

 

Repeatability 

±0.4% F.S. 

Analogue 

output 

Linearity 

±0.7% F.S. 

Accuracy (Display) 

 

±1.5% F.S. 

Accuracy (Operating temperature) 

 

 

±1.5% F.S.  ±1 digit 

Temperature characteristic 

±3.5% F.S. (25 

o

C standard) 

 

Warning 

  Special products (-X)  might have specifications which are different 

from those shown in this section. Contact SMC for specific drawings. 

2 Specifications (continued) 

2.4  Analogue Output 

 

 

 

 
 
 
 
 
 

3 Installation 

 

Warning 

Do not install the product unless the safety instructions have been read 
and understood. 

3.1  Piping 

Caution 

  Before piping make sure to clean up chips, cutting oil, dust etc. 

  Install the piping correctly in a safe place away from water and dust. 

  Cut the air tube perpendicularly. 

  Grip  the air tube and insert it into  the resin pipe  firmly by 8 mm or 

more from the end of the resin piping. The pulling force necessary for 
the piping inserted by 8 mm or more is approximate 25 N. 

  Insert the air tube for low pressure to piping marked ‘Lo’  and the air 

tube for high pressure to piping marked ‘Hi’. 

 

 

3.2  Environment 

Warning 

  Do not use in an environment where corrosive gases, chemicals, salt 

water or steam are present. 

  Do not use in an explosive atmosphere. 

  Do not expose to direct sunlight. Use a suitable protective cover. 

  Do not install in a location subject to vibration or impact in excess of 

the product’s specifications.  

  Do not mount in a location exposed to radiant heat that would result 

in temperatures in excess of the product’s specifications. 

 

4 Wiring 

4.1  Internal circuit and wiring 

  Output specification 

PSE550 

Voltage output: 1 to 5 V 

Output impedance: Approx. 1 kΩ

 

 

 

 

PSE550-28 

Current output: 4 to 20 mA 
Allowable load impedance:  500

Ω

 or less (at 24 VDC) 

  100

Ω

 or less (at 12 VDC) 

 

 

 

4.2  Attaching a sensor connector to the lead wire 

  The sensor wire sheath should be stripped as shown in the figure. 

  Do not cut the insulation. 

 

 

  The corresponding wire colour shown in the table should be pushed 

fully into the correct pin number marked on the sensor connector. 
 

Pin No. 

Wire colour 

PSE550 

PSE550-28 

Brown (DC+) 

Brown (LINE(+)) 

N.C. 

N.C. 

Blue (DC-) 

N.C. 

Black (IN: 1 to 5 V) 

Blue (LINE(-)) 

 

  Check that the above preparation has been performed correctly, then 

press part A by hand to make a temporary connection. 

  Press part A fully home using a suitable tool. 

 
 
 
 

 

 

  The sensor connectors cannot be re-used once they have been 

pressed fully closed. If connection failure or incorrect wiring occurs a 
new sensor connector must be used. 

  When connecting the sensor to a  PSE300 series monitor, use the 

connector for sensor lead wire (ZS-28-C) or an e-Con* connector 
from the table below. 

Maker 

Model No. 

Sumitomo 3M 

37104-3101-000FL 

Tyco Electronics 

1-1473562-4 

OMRON 

XN2A-1430 

* Refer to the manufacturers e-Con connector catalogue. 

 

ORIGINAL INSTRUCTIONS 

Air tubing (4 mm I.D.) 

Model 

PSE550 

PSE550-28 

Rated Pressure range 

0 to 2 kPa 

Operating pressure 
range 

-50 to 50 kPa 

Extended Analogue 
output range 

-0.2 to 0 kPa 

Withstand pressure 

65 kPa 

Applicable fluid 

Air, inert gases and incombustible gases 

Power supply 
voltage 

12 to 24 VDC ±10%  

(with 10% max. voltage ripple) 

Current consumption 

15 mA or less 

Analogue output 
specification 

Voltage output:  
1 to 5 VDC  
(rated pressure 
range) 
0.6 to 1 VDC 
(extended analogue 
output range) 
Output impedance: 
a

pprox. 1 kΩ

 

Current output: 
4 to 20 mA 
(rated differential 
pressure range) 
Maximum allowable 
load impedance: 

500 Ω

 (at 24 VDC) 

100 Ω (at 12 VDC)

 

 

Accuracy (at 25°C) 

±1% F.S. (rated pressure range) 
±3% F.S. (extended analogue output range) 

Linearity 

±0.5% F.S. 

Repeatability 

±0.3% F.S. 

Indicator light 

Orange LED is ON when energized 

E

nv

ir

on

m

e

nt

al

 

Enclosure 

IP40 

Ambient 
temperature 

Operation: 0 to 50°C   
Storage: -20 to 70°C  

(no condensation or freezing) 

Ambient humidity 

Operation, Storage: 35 to 85% RH  

(no condensation) 

Withstand 
voltage 

1000 VAC or more (50/60 Hz), 1 minute  

(between lead block and case) 

Insulation 
resistance 

50 

MΩ or more at 500 VDC 

 

(between lead block and case) 

Temperature 
characteristics 

±3% F.S. (at 25°C) 

Port size 

ø4.8 (ø4.4 at the end) resin piping 

(suitable for ø4 I.D. air tubing) 

Material of parts in 
contact with fluid 

Resin pipe: Nylon,  

Piston area of sensor: Silicon 

Weight with cable 

75 g 

Weight without cable 

35 g 

 

 
 
 
Analogue 
Output [V] 

Differential 
Pressure (kPa) 

PSE550:   1 to 5 VDC 

 
 
 
Analogue 
Output [V] 

PSE550-28:   4 to 20 mA 

Differential 
Pressure (kPa) 

Reviews: