background image

Model

PSE541

PSE543

Rated Pressure Range

0 to -101kPa

-100 to 100kPa

Withstand Pressure

500kPa

Fluid

Air, Non-corrosive gases, Incombustible gases

Power Supply Voltage

12 to 24VDC, ripple ( p-p ) 

±

10% or less ( Protected against inverse connection )

Current Consumption

15mA or less

Analog Output

Analog output 1 to 5VDC ( Rated Pressure Range ), Output impedance : Approx.1k

Accuracy
(Ambient temp. 25

°

C)

±

2%F.S. or less

Linearity

±

0.4%F.S. or less

Repeatability

±

0.2%F.S. or less

Influence from Power Supply
Voltage

±

0.8%F.S. or less

Enclosure

IP40

Operating Temp.Range

Operation: 0 to 50

°

C, Storage: -20 to 70

°

C ( No condensation or freezing )

Operating Humidity Range

Operation, Storage: 35 to 85% RH ( No condensation )

Withstand Voltage

1000VAC or more, 50/60Hz, 1minute ( Between lead block and case )

Insulation Resistance

50M

or more ( 500VDC by Megameter ) ( Between lead block and case )

Vibration proof

10 to 500Hz smaller one 1.5mm or 98m/s

2

 double amplitude each in directions of

X, Y and Z for 2 hours

En

v

iro

n

m

e

n

t

Impact proof

980m/s

2

, 3 times each in directions of X, Y and Z respectively

Temp. Characteristic

±

2%F.S. or less ( 25

°

C)

Pipe Specification

Model

M3

M5

01

N01

R04

R06

IM5

IM5H

Port size

M3 

×

 0.5

M5 

×

 0.8

R1/8,

M5 

×

 0.8

NPT1/8,

M5 

×

 0.8

φ

4

reducer

φ

6

reducer

M5 female screw.

Through type

M5 female screw.

Through type

with setting hole

Case : PBT

Piping port : SUS303

Case : PBT

Piping port : C3604BD

PBT

Case : PBT

Piping port : A6063S-T5

Material

Pressure-detection component, Sensor receiving area : Silicon,      O-ring : NBR

Lead wire

3-cores ellipse-shaped cable ( 0.15mm

2

 )

Applied

lead
wire

42.4g

42.7g

49.3g

41.4g

41.6g

43.3g

44.1g

Ma

s

s

N/A

lead
wire

2.9g

3.4g

9.8g

1.9g

2.1g

3.8g

4.6g

Specification

PS##-OMG0004

- 7 -

Summary of Contents for PSE540 Series

Page 1: ...Technical Specification Pressure Sensor PSE540 Series No PS OMG0004...

Page 2: ...Contents Safety Model Indication Method Specification Full View with Dimensions Installation Examples of Internal Circuit and Wiring P2 P6 P7 P8 P9 P9 1 PS OMG0004...

Page 3: ...etc Equipment or apparatus that conforms with those mentioned above n Contact our sales department when plans are made for the product to be used for the system 2 including equipment that concerns its...

Page 4: ...k the c pressure sensor regularly to ensure proper operation Otherwise malfunction can cause an accident These instructions must be followed while in maintenance Turn off the power supply Stop the sup...

Page 5: ...a wrench R NPT1 8 7 to 9 N m When piping apply the wrench only to the metal option attachment to be piped integrated into the piping Applying the wrench in other position can break the pressure senso...

Page 6: ...remnant of wires from entering this product Take proper measures for the remnant not to enter the pressure sensor in order to prevent failure or malfunction Do not expose the pressure sensor to vibrat...

Page 7: ...r Range 1 For vacuum 0 to 101kPa 3 For compound 100 to 100kPa Pipe Specification M3 M3 0 5 M5 M5 0 8 01 R1 8 with M5 female screw N01 NPT1 8 with M5 female screw R04 4 reducer R06 6 reducer IM5 M5 fem...

Page 8: ...1minute Between lead block and case Insulation Resistance 50M or more 500VDC by Megameter Between lead block and case Vibration proof 10 to 500Hz smaller one 1 5mm or 98m s2 double amplitude each in d...

Page 9: ...R06 PSE54 A M3 M5 PSE54 A IM5 PSE54 A IM5H A PSE54 A M5 PSE54 A M3 11 5 10 8 B 3 5 3 14 4 10 A PSE54 A R06 PSE54 A R04 6 4 B 20 18 B 10 A M5 0 8 01 R1 8 N01 NPT1 8 M3 M3 0 5 M5 M5 0 8 Width across fl...

Page 10: ...nnection A part center is straightly pushed in by tools such as pliers Re use cannot be performed once it connects the connector for sensor connection completely When you fail in the connection mistak...