 Operator

 Safety

 Do not disassemble, modify (including change of printed circuit board) or repair.

    An injury or failure can result.

 

 Do not operate beyond specification range.

 

  Do not use the pressure sensor for inflammable or harmful gas or fluid.

 

  Operation at a range that exceeds the specifications can cause a fire, malfunction, or damage to

the pressure sensor.

  Verify the specifications before use.

 Do not use it in an atmosphere of an inflammable, an explosive and corrosive gas.

 

A fire, explosion and corrosion can result.

 

This pressure sensor is not an explosion-proof type.

 

These instructions must be followed when using this pressure sensor in an interlocking circuit:

   

 Provide double interlocking by another system such as mechanical protection.

   

 Check the c pressure sensor regularly to ensure proper operation.

Otherwise malfunction can cause an accident.

 

These instructions must be followed while in maintenance:

 Turn off the power supply.

 Stop the supplied air, exhaust the residual pressure and verify the release of air before

performing maintenance.

Otherwise it can cause injury.

 

Perform proper functional checks and leak tests after maintenance.

  Stop operation when an abnormality is observed such that the sensor does not work properly or

there is a leakage of fluid.

  Safety is not be assured due to unexpected malfunction.

This technical specification has been written for those who have knowledge of machinery and

apparatus that use pneumatic equipment and have full knowledge of assembly, operation and
maintenance of such equipment.

Please read this technical specification carefully and understand it before assembling, operating or

providing maintenance to the pressure sensor.

- 3 -

PS##-OMG0004

Summary of Contents for PSE540 Series

Page 1: ...Technical Specification Pressure Sensor PSE540 Series No PS OMG0004...

Page 2: ...Contents Safety Model Indication Method Specification Full View with Dimensions Installation Examples of Internal Circuit and Wiring P2 P6 P7 P8 P9 P9 1 PS OMG0004...

Page 3: ...etc Equipment or apparatus that conforms with those mentioned above n Contact our sales department when plans are made for the product to be used for the system 2 including equipment that concerns its...

Page 4: ...k the c pressure sensor regularly to ensure proper operation Otherwise malfunction can cause an accident These instructions must be followed while in maintenance Turn off the power supply Stop the sup...

Page 5: ...a wrench R NPT1 8 7 to 9 N m When piping apply the wrench only to the metal option attachment to be piped integrated into the piping Applying the wrench in other position can break the pressure senso...

Page 6: ...remnant of wires from entering this product Take proper measures for the remnant not to enter the pressure sensor in order to prevent failure or malfunction Do not expose the pressure sensor to vibrat...

Page 7: ...r Range 1 For vacuum 0 to 101kPa 3 For compound 100 to 100kPa Pipe Specification M3 M3 0 5 M5 M5 0 8 01 R1 8 with M5 female screw N01 NPT1 8 with M5 female screw R04 4 reducer R06 6 reducer IM5 M5 fem...

Page 8: ...1minute Between lead block and case Insulation Resistance 50M or more 500VDC by Megameter Between lead block and case Vibration proof 10 to 500Hz smaller one 1 5mm or 98m s2 double amplitude each in d...

Page 9: ...R06 PSE54 A M3 M5 PSE54 A IM5 PSE54 A IM5H A PSE54 A M5 PSE54 A M3 11 5 10 8 B 3 5 3 14 4 10 A PSE54 A R06 PSE54 A R04 6 4 B 20 18 B 10 A M5 0 8 01 R1 8 N01 NPT1 8 M3 M3 0 5 M5 M5 0 8 Width across fl...

Page 10: ...nnection A part center is straightly pushed in by tools such as pliers Re use cannot be performed once it connects the connector for sensor connection completely When you fail in the connection mistak...

Reviews: