-27-
No.PS
※※
-OMU0012-A
■
[F 0] Switching function of pressure range, display unit and switch output specifications
Pressure range setting
Pressure range that matches with the connected sensor can be selected.
In addition, the required range can be set and displayed. (Additional range)
•
Relation between analog input and digital display
Set value
A
B
0.002
0 kPa
2 kPa
-0.1
0 kPa
-101 kPa
F0.1
-100 kPa
100 kPa
0.1
0 kPa
100 kPa
0.5
0 kPa
500 kPa
1
0 MPa
1 MPa
2
0 MPa
2 MPa
5
0 MPa
5 MPa
10
0 MPa
10 MPa
20
0 MPa
20 MPa
25
0 MPa
25 MPa
USEr
Input value (setting)
Input value (setting)
•
Available display unit and minimum set value
Pressure range
Rated
pressure
Display
MPa
kPa
Pa
Kgf/cm
2
bar
mbar
psi
inHg
mmHg mmH
2
O
Fine differential pressure
2 kPa
0.002
-
0.001
1
-
-
0.01
0.001
-
-
0.1
Vacuum
101 kPa
-0.1
0.001
0.1
-
0.001
0.001
-
0.01
0.1
1
-
Compound
±100 kPa
F0.1
0.001
0.1
-
0.001
0.001
-
0.02
0.1
1
-
Low pressure
100 kPa
0.1
0.001
0.1
-
0.001
0.001
-
0.01
-
-
-
Positive pressure
500 kPa
0.5
0.001
1
-
0.01
0.01
-
0.1
-
-
-
1 MPa
1
0.001
1
-
0.01
0.01
-
0.1
-
-
-
High pressure
2 MPa
2
0.001
1
-
0.01
0.01
-
0.2
-
-
-
5 MPa
5
0.01
-
-
0.1
0.1
-
1
-
-
-
10 MPa
10
0.01
-
-
0.1
0.1
-
1
-
-
-
20 MPa
20
0.01
-
-
0.1
0.1
-
2
-
-
-
25 MPa
25
0.02
-
-
0.2
0.2
-
2
-
-
-
Additional range × 1
USEr
It varies depending on the minimum unit setting of the additional range.
(All pressure units are selectable)