-25-
No.PS
※※
-OMW0005-A
3 Step Setting Mode
3 step setting mode
In this mode, the set values can be input in just 3 steps.
Use this mode if the product is to be used straight away, after changing only the set values.
(The current pressure value is displayed on the main display.)
<Operation>
[3 step setting mode (hysteresis mode)]
In the 3 step setting mode, the set value (P_1 or n_1, P_2 or n_2) and hysteresis (H_1, H_2) can be
changed.
After selecting the channel, set the items on the sub display (set value or hysteresis) with the DOWN button.
When changing the set value, follow the operation below. The hysteresis setting can be changed in the
same way.
(1) Press the SET button once when the item to be changed is displayed on the sub display.
The set value on the sub display (right) will start flashing.
(2) Press the UP or DOWN button to change the set value.
The set value can be increased with UP button and can be reduced with DOWN button.
•Press the UP button once to increase the value by one digit, press and hold to continuously increase.
•Press the DOWN button once to reduce the value by one digit, press and hold to continuously
reduce.
•When the UP and DOWN buttons are pressed and held simultaneously for 1 second or longer, the
set value is displayed as [- - -], and the set value will be the same as the current pressure value
automatically (snap shot function (Refer to page
)). Afterwards, it is possible to adjust the value by
pressing the UP or DOWN button.
(3) Press the SET button to complete the setting.