● Key-lock function
The key-lock function is used to prevent errors occurring due to unintentional changes of the set values.
Even after the key lock has been set, the display switch is active between the simple display of the set value
and the sub screen.
< Screen display during key lock >
[LoC] appears for 1 second by pressing the
button.The sub screen will scroll through the OUT1 set
values.It will return to measurement mode in about 10 seconds.
Pressing the
or
buttons will change the sub screen display.
The peak and bottom hold values and the accumulated flow can be viewed, but not cleared.
<Operation when unlocking the key>
The operation for unlocking the key differs depending on the security code request [F81] (page 46).
[F81] Security code request
Security code used to cancel key lock
Invalid
Not required
Valid
Required
<When setting a key lock>
* The following key lock settings are the same for enabling / disabling the security code request [F81].
(1) Press the
button for 5 seconds or longer in measurement mode.
The current setting [UNLoC] flashes on the sub screen.
Sub screen
(2) Press the
or
button to select locking[LoC].
(3) Press the
button to select the setting.Return to measurement mode.
<When unlocking the key lock>
* The following procedure of cancelling the key lock should be followed when [F81] Security code request is
set to invalid.
(1) Press the
button for 5 seconds or longer in measurement mode.
The current setting [LoC] flashes on the sub display.
Sub screen
(2) Press the
or
button to select unlocking [UNLoC].
(3) Press the
button to select the setting.Return to measurement mode.
*: During simple display of the set value, setting and release of key-lock is not available. Operate in
measurement mode.
Unlocking Locking
Locking Unlocking
Summary of Contents for LFE0 Series
Page 1: ...Doc No LFE OMZ0013 Product Name Flow Monitor Model Series Product Number LFE0 SMC Corporation ...
Page 36: ... 35 No LFE OMZ0013 List of output modes for fluid temperature ...
Page 42: ... 41 No LFE OMZ0013 F20 External input This item is not used for this specification ...
Page 66: ... 65 No LFE OMZ0013 Dimensions Front protective cover Panel mount adapter R ...