![SMC Networks LEY Operation Manual Download Page 33](http://html1.mh-extra.com/html/smc-networks/ley/ley_operation-manual_1299663033.webp)
- 32 -
4.4 Parameter setting
Initial setting for the basic parameters
Refer to the controller’s (LEC series) operation manual for detail.
As the “basic parameter” is unique data of each actuator, if an actuator other than the “electric actuator /
rod type” is used, refer to the operation manual of each actuator and the controller’s (LEC series)
Note1) Become effective after restarting the controller.
Note 2)The origin offset is used for the “return to origin”. / See 2) Origin offset on p.33
<Return to origin>
Before the positioning and pushing operation, “return to origin” is necessary to establish the origin. The
current position value of the actuator increases if the rod extend (move in the CW direction). (The rod
moving direction to be increased cannot be changed.)
1) Flow of return to origin
Input the origin signal
→Move toward origin → Stop moving (pushing) → Move in the opposite direction → Origin
Description(Extract)
Initial input value
Input range
Controller ID
1
1 to 64 Note 1)
IO pattern
1: 64
-
Acceleration /
deceleration pattern
2
-
S-motion ratio
7
-
Stroke (+)
1000.00
-
Stroke (-)
-1000.00
-
Maximum speed
Max. speed of each
product
Step data input limit:
Max. speed of each product
Maximum acceleration /
deceleration
3000
to 3000
Default In positioning
0.5
0.5 to product stroke
Origin offset
0.00
-9000.00 to 9000.00 Note 2)
Maximum pushing
force
LEY 16
:
85
to 85
LEY 25
:
65
to 65
LEY 32
:
85 / LEY40
:
65
LEY 32
:
to 85 / LEY40
:
to 65
LEY 16A
:
95
to 95
LEY 25A
:
95
to 95
Parameter protect
1: StepData
Changeable parameter
1: StepData, 2: Common
Enable switch
2: Disable
Select 1:Enable or 2:Disable when using a teaching box
Model name
Part no. of each product
Only the English characters and numbers are
changeable.
W-area output end 1
0.00
-
W-area output end 2
0.00
-
Origin correction data
0.00
-
Initial set value for
the electric
actuator
Retracted direction
(CCW direction)
Stroke end of
Retracted
direction
Moving distance
2mm
(Not changeable)