- 21 -
4.3 Step data setting method
Refer to the operation manual of the controller (LEC series) for details.
This operation manual specifies the electric actuator, if an actuator other than the electric actuator is used,
refer to the operation manual of each type of actuator and controller (LEC series) regarding the
description of step data.
Caution
The actuator body and controller are sold as a package.
If when only the actuator is purchased separately, confirm that the combination of the controller, which
you have and the actuator is compatible. / See 6.3
Caution(1) on P.38.
<Be sure to check the following before use.>
(1) Check that actuator label for model number.
This matches the controller.
(2) Check Parallel I /O configuration matches (NPN or PNP).
Positioning operation
In the positioning operation, the electric actuator transfers to and stops at the target position.
The following image shows the set items and operation.
<Confirmation of reaching the target position during the positioning operation>
When the electric actuator reaches the range of the target position, the target position reaching
signal
【
INP
】
(in position) is outputted.
When the rod of actuator enters the range of
【
in position
】
, the INP output signal turns on.
Caution
Please use it by "Pushing operation" when you make it hold.
The product may be damaged by the impact when using it in "Positioning operation".
/ See 7.2
Caution(2) on p.41
Speed
Acceleration
Deceleration
Speed
ON
INP output
Position
ON
OFF
In pos
(1)
(2)
LEY16B-100
NPN