1 - 12
1. FUNCTIONS AND CONFIGURATION
1.8 Configuration including auxiliary equipment
POINT
Equipment other than the driver and servo motor are optional or recommended
products.
(1) LECSB
□
-
□
(a) For 3-phase or 1-phase 200 to 230VAC
(Note 3)
Power supply
Line noise filter
(FR-BSF01)
R S T
Magnetic
contactor
(MC)
No-fuse breaker
(NFB) or fuse
CN5
CN3
Regenerative
option
P
C
L
11
L
21
Power factor
improving DC
reactor
(FR-BEL)
Analog monitor
CN1
CN2
CN4
Junction terminal block
CN6
P
1
P
2
U V
W
Servo amplifier
Servo motor
(Note 1)
Battery
MR-J3BAT
L
1
L
2
L
3
(Note 2)
(Note 2)
MR Configurator
Personal
computer
Note 1. The battery is used for the absolute position detection system in the position control mode.
3.For 1-phase 200 to 230VAC, connect the power supply to L
1
L
2
and leave L
3
open. Refer to section 1.3 for the power supply
specification.
LEC-MR-J3BAT
Driver
(Mitsubishi
Electric
Corporation)
Set up software
(
MR Configurator2
TM
)
Monitor cable(1m)
(
MR-J3CN6CBL1M
)
(Mitsubishi Electric Corporation)