background image

Design/Selection

Warning

1. Use the specified voltage.

If the applied voltage is higher than the specified voltage, mal-

function and damage to the controller may result. If the applied 

voltage is lower than the specified voltage, there is a possibility 

that  the  load  cannot  be  moved  due  to  internal  voltage  drop. 

Check the operating voltage prior to start.

2. Do not use the products outside the specifications.

Otherwise, fire, malfunction or damage to the product can re-

sult.  Check the specifications prior to use.

3. Install an emergency stop circuit.

Install an emergency stop outside the enclosure in easy reach 

to the operator so that the operator can stop the system opera-

tion immediately and intercept the power supply.

4. To prevent danger and damage due to a breakdown 

or malfunction of these products, which may occur 

at a certain probability, a backup system should be  

arranged  in  advance  by  using  a  multiple-layered 

structure or by making a fail-safe equipment design, 

etc.

5. If there is a risk of fire or personal injury due to ab-

normal heat generation, sparking, smoke generated 

by the product, etc., cut off the power supply from 

this product and the system immediately.

Caution

1. When using an actuator not horizontally mounted, 

an actuator with the lock option is recommended.

Burnout of the internal parts of the controller may occur. If the 

actuator is not equipped with a lock, it will move and drop the 

workpiece when the power and servo are turned OFF.

Handling

Warning

1. Check the voltage using a tester at least 5 minutes 

after  power-off  when  connecting/disconnecting 

cables.

Otherwise, electric shock, injury, fire, or serious damage can 

result.

2. Do  not  touch  the  inside  of  the  controller  and  its 

connector.

Otherwise, electric shock or failure can result.

3. Do not operate or set up this equipment with wet 

hands.

Otherwise, electric shock can result.

4. Do not use a product that is damaged or missing 

any components.

Electric shock, fire or injury can result.

5. Use  only  the  specified  combination  between  the 

electric actuator and controller.

Not  doing  so  may  cause  damage  to  the  actuator  or  to  the 

controller.

Handling

Warning

6. Be careful not to touch, get caught or hit by the 

workpiece while the actuator is moving.

An injury can result.

7. Do not connect the power supply or power up the 

product until it is confirmed that the workpiece can 

be  moved  safely  within  the  area  that  can  be 

reached by the workpiece.

Otherwise, the movement of the workpiece may cause an 

accident.

8. Do not touch the product when it is energized and 

f o r   s o m e   t i m e   a f t e r   t h e   p o w e r   h a s   b e e n 

disconnected, as it is very hot.

Otherwise, it may cause burns due to the high temperature.

9. Check the voltage using a tester at least 5 minutes 

after power-off when performing installation, wiring 

and maintenance.

Otherwise, electric shock, fire or injury can result.

10. Do  not  use  the  products  in  an  area  where  they 

could be exposed to dust, metallic powder, ma-

chining chips or splashes of water, oil or chemi-

cals.

Otherwise, a failure or malfunction can result.

11. Do not use the products in a magnetic field.

Otherwise, a malfunction or failure can result.

12. Do not use the products in an environment where 

flammable, explosive or corrosive gases, liquids or 

other substances are present.

Otherwise, fire, explosion or corrosion can result.

13. Avoid  heat  radiation  from  strong  heat  sources, 

such as direct sunlight or a hot furnace.

Otherwise,  it  will  cause  a  failure  to  the  controller  or  its 

peripheral devices.

14. Do not use the products in an environment with 

cyclic temperature changes.

Otherwise,  it  will  cause  a  failure  to  the  controller  or  its 

peripheral devices.

15. Do not use the products in an environment where 

surges are generated.

Devices (solenoid type lifters, high frequency induction fur-

naces, motors, etc.) that generate a large amount of surge 

around the product may lead to deterioration or damage to 

the internal circuits of the products. Avoid supplies of surge 

generation and crossed lines.

16. Do not install the products in a place subject to vi-

bration and impact.

Otherwise, a malfunction or failure can result.

17. If  this  product  is  used  with  a  relay  or  solenoid 

valve,  use  the  built-in  surge  absorbing  element 

type.

18. This product cannot be used if multiple axes are 

fixed to one workpiece.

JXC73/83/93

 Series

Controller and Peripheral Devices/

Specific Product Precautions

Be sure to read this before handling the products. For Safety Instructions and Electric 

Actuator  Precautions,  refer  to  Handling  Precautions  for  SMC  Products  and  the 

Operation Manual on the SMC website, http://www.smcworld.com

13

Summary of Contents for JXC73 Series

Page 1: ...Step Motor Controller Parallel I O Type Positioning pushing operation Step data input Max 2048 points Space saving reduced wiring 4 axis synchronous control Absolute relative position coordinates ins...

Page 2: ...Executes the specified step number Stop Displays whether the step number is being executed or stopped All axes return to origin Performs a return to origin of all the valid axes Step data window Move...

Page 3: ...ENC To MOT To CI To C PWR PLC VI O cable Option Provided by customer Provided by customer VElectric actuators 1 VMotor control power supply connector Accessory Applicable cable size AWG20 0 5 mm2 VMo...

Page 4: ...et cable Category 5 or higher Provided by customer Provided by customer VElectric actuators 1 V Motor control power supply connector Accessory VMotor power supply connector Accessory VCable with main...

Page 5: ...n Actuators should be ordered separately For the Speed Work Load graph of the actuator refer to the LECPA section in the Model Selection page of the WEB catalog of electric actuators 4 axis type 4 axi...

Page 6: ...er supply with inrush current protection for the motor drive power and motor control power supply 2 Power consumption depends on the actuator connected Refer to the actuator specifications for further...

Page 7: ...the dimension drawings above for the mounting dimensions L Dimension JXC Z1 with 6 mounting screws This should be used when the DIN rail mounting bracket is mounted onto a screw mounting type control...

Page 8: ...nsion drawings above for the mounting dimensions L Dimension JXC Z1 with 6 mounting screws This should be used when the DIN rail mounting bracket is mounted onto a screw mounting type controller after...

Page 9: ...4 lock release 0 M PWRcv Motor power supply connector 1 For Axis 3 4 Motor power supply Common 1 P1 P2 EtherNet IPTM communication connector Connect Ethernet cable 1 Connectors are included Refer to...

Page 10: ...erminal LKRLS terminal are common M 24V Motor power supply Power supply supplied to the motor power Manufactured by PHOENIX CONTACT Part no MSTB2 5 2 STF 5 08 Terminal name Function Details C 24V Moto...

Page 11: ...18 White Black 4 23 White Red 1 28 White Red 2 33 White Red 3 38 White Red 4 4 Yellow Black 1 9 Yellow Black 2 14 Yellow Black 3 19 Yellow Black 4 24 Yellow Red 1 29 Yellow Red 2 34 Yellow Red 3 39 Ye...

Page 12: ...ing changes depending on the type of the parallel I O NPN or PNP Output Signal Name Details OUT0 to OUT8 Outputs the step data no during operation BUSY OUT9 Outputs when the operation of the actuator...

Page 13: ...ame Details BUSY1 Busy signal for axis 1 BUSY2 Busy signal for axis 2 BUSY3 Busy signal for axis 3 BUSY4 Busy signal for axis 4 AREA1 Area signal for axis 1 AREA2 Area signal for axis 2 AREA3 Area sig...

Page 14: ...ece while the actuator is moving An injury can result 7 Do not connect the power supply or power up the product until it is confirmed that the workpiece can be moved safely within the area that can be...

Page 15: ...Safety Instructions Be sure to read the Handling Precautions for SMC Products M E03 3 and Operation Manual before use...

Reviews: