- 50 –
No.JXC
※
-OMY0002
Power
IN0~5
SVON
DRIVE
OUT0~5
BUSY
SVRE
SETON
INP
External Lock
E
lectric actuator
Output
Input
Speed
0mm/s
24V
0V
OFF
ON
ON
OFF
ON
OFF
・
・
・
・
・
・
・
・
・
・
・
・
・
Min15m
s
(
3
)
Pushing operation
- Procedures- - Timing chart Pushing operation -
1) Input step data No. (IN0 to IN5)
↓
2) DRIVE is turned ON.
(OUT0 to OUT5 is turned off.)
→Scan the step data number (from IN0 to
IN5).
After this, if DRIVE is turned OFF, the step
data number will be output (from the
outputs OUT0 to OUT5).
↓
3) BUSY is turned ON.
(The Pushing operation starts.)
↓
4) When INP output is turned ON and BUSY
is turned OFF, the pushing operation will be
completed
(The electric actuator generates the force
larger than that specified in "TriggerLV" of
the step data).
If the electric actuator is within the "In
position" range, INP will be turned ON
but if not, it will remain OFF.
Scan the step data no.
Input the step data no.
Output the
step data no.