background image

Safety Instructions

Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.

Caution

SMC products are not intended for use as instruments for legal 

metrology.

Measurement instruments that SMC manufactures or sells have not been 
qualified by type approval tests relevant to the metrology (measurement) laws 
of each country. Therefore, SMC products cannot be used for business or 
certification ordained by the metrology (measurement) laws of each country.

Compliance Requirements

1) ISO 4414: Pneumatic fluid power – General rules relating to systems.

 

ISO 4413: Hydraulic fluid power – General rules relating to systems.

 

IEC 60204-1: Safety of machinery – Electrical equipment of machines.

 

(Part 1: General requirements)

 

ISO 10218-1: Manipulating industrial robots – Safety.

 etc.

Caution

 indicates a hazard with a low level of risk which, 

if not avoided, could result in minor or moderate injury.

Caution:

Warning

 indicates a hazard with a medium level of risk which, 

if not avoided, could result in death or serious injury.

Warning:

Danger :

Danger

 indicates a hazard with a high level of risk which, 

if not avoided, will result in death or serious injury.

Warning

Caution

1. The compatibility of the product is the responsibility of the 

person who designs the equipment or decides its 

specifications.

Since the product specified here is used under various operating conditions, 
its compatibility with specific equipment must be decided by the person who 
designs the equipment or decides its specifications based on necessary 
analysis and test results. The expected performance and safety assurance 
of the equipment will be the responsibility of the person who has determined 
its compatibility with the product. This person should also continuously 
review all specifications of the product referring to its latest catalog 
information, with a view to giving due consideration to any possibility of 
equipment failure when configuring the equipment.

2. Only personnel with appropriate training should operate 

machinery and equipment.

The product specified here may become unsafe if handled incorrectly. The 
assembly, operation and maintenance of machines or equipment including 
our products must be performed by an operator who is appropriately trained 
and experienced.

3. Do not service or attempt to remove product and machinery/

equipment until safety is confirmed.

1. The inspection and maintenance of machinery/equipment should only be 

performed after measures to prevent falling or runaway of the driven 
objects have been confirmed. 

2. When the product is to be removed, confirm that the safety measures as 

mentioned above are implemented and the power from any appropriate 
source is cut, and read and understand the specific product precautions 
of all relevant products carefully.

3. Before machinery/equipment is restarted, take measures to prevent 

unexpected operation and malfunction.  

4.  Contact SMC beforehand and take special consideration of 

safety measures if the product is to be used in any of the 

following conditions. 

 

1. Conditions and environments outside of the given specifications, or use 

outdoors or in a place exposed to direct sunlight.

2. Installation on equipment in conjunction with atomic energy, railways, air 

navigation, space, shipping, vehicles, military, medical treatment, 
combustion and recreation, or equipment in contact with food and 
beverages, emergency stop circuits, clutch and brake circuits in press 
applications, safety equipment or other applications unsuitable for the 
standard specifications described in the product catalog. 

3. An application which could have negative effects on people, property, or 

animals requiring special safety analysis. 

4. Use in an interlock circuit, which requires the provision of double interlock 

for possible failure by using a mechanical protective function, and 
periodical checks to confirm proper operation.

1. The product is provided for use in manufacturing industries.

The product herein described is basically provided for peaceful use in 
manufacturing industries. 
If considering using the product in other industries, consult SMC beforehand 
and exchange specifications or a contract if necessary. 
If anything is unclear, contact your nearest sales branch.

Limited warranty and Disclaimer/

Compliance Requirements

The product used is subject to the following “Limited warranty and Disclaimer” and 
“Compliance Requirements”.
Read and accept them before using the product.

Limited warranty and Disclaimer

1. The warranty period of the product is 1 year in service or 1.5 years after 

the product is delivered, whichever is first.

2)

Also, the product may have specified durability, running distance or 

replacement parts. Please consult your nearest sales branch.

2. For any failure or damage reported within the warranty period which is clearly our 

responsibility, a replacement product or necessary parts will be provided. 

This limited warranty applies only to our product independently, and not to any 

other damage incurred due to the failure of the product.

3. Prior to using SMC products, please read and understand the warranty terms 

and disclaimers noted in the specified catalog for the particular products.

2) Vacuum pads are excluded from this 1 year warranty.

A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. 
Also, even within the warranty period, the wear of a product due to the use of the vacuum pad 
or failure due to the deterioration of rubber material are not covered by the limited warranty.

1. The use of SMC products with production equipment for the manufacture of 

weapons of mass destruction (WMD) or any other weapon is strictly prohibited.

2. The exports of SMC products or technology from one country to another are 

governed by the relevant security laws and regulations of the countries involved 

in the transaction. Prior to the shipment of a SMC product to another country, 

assure that all local rules governing that export are known and followed.

These safety instructions are intended to prevent hazardous situations and/or 

equipment damage. These instructions indicate the level of potential hazard with 

the labels of 

“Caution,”

 

“Warning”

 or 

“Danger

.

 They are all important notes for 

safety and must be followed in addition to International Standards (ISO/IEC)

1)

and other safety regulations.

Safety Instructions

Summary of Contents for JSXFA Series

Page 1: ...s specific testing conditions JSXFA 06 Pilot valve orifice is 5 mm or larger 2 Comparison with SMC existing model Air consumption 35 3 reduction Peak pressure Size 3 4 20A 1 25A 1 1 2 40A Compression...

Page 2: ...or JSXFA Series Easier maintenance Springless diaphragm allows for easy maintenance of valve Main valve and sub valve for 40A included in maintenance kit Flow rate characteristics 40 1 2 increase Opti...

Page 3: ...cing Pulse Valve Filter Header tank Application of the pulse valve Pulse Valve JSXFA Series General production line Mining Steel and cement Pharmaceutical Agriculture livestock Food Pulse blow for var...

Page 4: ...peratures B 40 to 60 C Symbol 2 OUT 1 IN Caution Selection of Pilot Valve For the pilot valve orifice diameter 5 mm or larger is recommended When the pilot orifice diameter is 3 mm or larger and less...

Page 5: ...omated 7 Compression nut ADC 8 Hexagon bolt Stainless steel Component Parts No Description Material 1 Body ADC 2 Main valve Resin 3 O ring NBR 4 Bonnet ADC 5 Hexagon bolt Stainless steel Component Par...

Page 6: ...J K JSXFA Series Port size 06 10 sizes Port size 14 size Dimensions JSXFAE Compression Fitting Type Dimensions mm Dimension in shows the dimension after tightening Model Port size P A B C E F G H J K...

Page 7: ...B A 52 20 Silencer Option F E D C B 2 x P Port size Pilot port 1 8 1 4 Rc NPT G Exhaust port 3 8 20 G D F E Pulse Valve Valve for Dust Collector JSXFA Series Port size 06 10 sizes Port size 14 size D...

Page 8: ...the pilot valve to atmosphere the pressure in the pressure action chamber decreases force pushing the main valve down force pushing the main valve up opening the main valve Because of this the air fl...

Page 9: ...erring to Fig 1 If the valve is assembled in incorrect direction it can cause a malfunction 2 Mount the O ring to the body groove See Fig 2 After mounting of the O ring check if the O ring is fitted p...

Page 10: ...iple board connection Interrupt Operation Function A two time hitting function is adopted to improve the bag filter dusting efficiency Turn ON the DIP switch for two time hitting OFF for one time hitt...

Page 11: ...re differential The maximum pressure differential the difference between the inlet and outlet pressure which is allowed for operation When the outlet pressure is 0 MPa this becomes the maximum oper at...

Page 12: ...e adopted 2 Continuous valve open The valve is for pulse operation Do not open the valve contin uously Since a large amount of air is consumed the dia phragm will oscillate chatter due to insufficient...

Page 13: ...3 Painting and coating Warnings or specifications printed or labeled on the product should not be erased removed or covered up Piping Warning 1 During use deterioration of the tube or damage to the fi...

Page 14: ...losive atmospheres 3 Do not use in locations subject to vibration or impact 4 Do not use in locations where radiated heat will be received from nearby heat sources 5 Employ suitable protective measure...

Page 15: ...ironments outside of the given specifications or use outdoors or in a place exposed to direct sunlight 2 Installation on equipment in conjunction with atomic energy railways air navigation space shipp...

Reviews: