background image

Appearance

Caution

1.  Surface treatment is applied to the product to 

improve corrosion resistance. There may be spot 
pattern on the surface depending on the treatment 
condition, but there is no problem in use.

 condition, but there is no problem in use.

Wiring

Warning

 1.

  The controller starts its output the moment the power switch is 

turned ON. Be aware that even if the power switch is turned 
OFF, power is connected to the terminal block.

Caution

1.

  Make sure that the power supply voltage to be input matches 

the voltage in the controller’s specifications. The power supply 
voltage that has been input becomes the voltage that is output 
to the solenoid valves.

2.

  Connect a ground that is rated Class 3 or greater to the power 

supply terminal block’s FG.

3.

  If the power source is DC, use caution to its polarity. If the 

polarity is incorrect, it may result in a malfunction or damage.

4.

 For details, refer to the separate Operation Manual.

5.

  The solenoid valve mounted on the controller should be 

equipped with a surge voltage suppressor.

Operating Environment

Warning

 1.

 Operate under conditions that are free of vibration and impact.

2.

  Operate in an ambient temperature range between 0

°

C and 

50

°

C.

3.

  Operate in an ambient humidity range between 45% to 80% 

(no condensation allowed).

Dedicated Controller for Operation

VXFC Series

Operating Environment

Warning

 1.  Do not use in an atmosphere having corrosive 

gases, chemicals, sea water, water vapor, or where 
there is direct contact with any of these.

2.  Do not use in explosive atmospheres.
3.  Do not use in locations subject to vibration or impact.
4.  Do not use in locations where radiated heat will be 

received from nearby heat sources.

5.  Employ suitable protective measures in locations 

where there is contact with oil or welding spatter, 
etc.

Maintenance

Warning

 1. Removing the product

The valve becomes hot depending on the fluid temperature. 
Confirm that the valve temperature has dropped sufficiently 
before performing work. If touched inadvertently, there is a 
danger of being burned.

 

1.  Shut off the fluid supply and release the fluid pressure in the 

system.

2. Shut off the power supply.
3. Remove the product.

 2. Low frequency operation

Switch valves at least once every 30 days to prevent malfunc-
tion. Also, in order to use it under the optimum state, conduct a 
regular inspection once a half year.

 3.  Disassembly

Do not disassemble for purposes other than the main valve 
replacement, or malfunction may occur.
Refer to the Disassembly/Assembly Procedure on page 8 for 
the replacement of the main valve.

Caution

1. Filters

 

1. Be careful regarding clogging of filters.
2.  Replace filter elements after one year of use, or earlier if the 

pressure drop reaches 0.1 MPa.

2. Storage

In case of long term storage after use, thoroughly remove all 
moisture to prevent rust and deterioration of rubber materials 
etc.

 3. Exhaust the drainage from an air filter periodically.

JSXFA 

Series

Specific Product Precautions 3

Be sure to read this before handling the products. Refer to the back cover for safety instruc-
tions. For 2-port solenoid valve for fluid control precautions, refer to the “Handling Precautions 
for SMC Products” and the “Operation Manual” on the SMC website: https://www.smcworld.com

13

Summary of Contents for JSXFA Series

Page 1: ...s specific testing conditions JSXFA 06 Pilot valve orifice is 5 mm or larger 2 Comparison with SMC existing model Air consumption 35 3 reduction Peak pressure Size 3 4 20A 1 25A 1 1 2 40A Compression...

Page 2: ...or JSXFA Series Easier maintenance Springless diaphragm allows for easy maintenance of valve Main valve and sub valve for 40A included in maintenance kit Flow rate characteristics 40 1 2 increase Opti...

Page 3: ...cing Pulse Valve Filter Header tank Application of the pulse valve Pulse Valve JSXFA Series General production line Mining Steel and cement Pharmaceutical Agriculture livestock Food Pulse blow for var...

Page 4: ...peratures B 40 to 60 C Symbol 2 OUT 1 IN Caution Selection of Pilot Valve For the pilot valve orifice diameter 5 mm or larger is recommended When the pilot orifice diameter is 3 mm or larger and less...

Page 5: ...omated 7 Compression nut ADC 8 Hexagon bolt Stainless steel Component Parts No Description Material 1 Body ADC 2 Main valve Resin 3 O ring NBR 4 Bonnet ADC 5 Hexagon bolt Stainless steel Component Par...

Page 6: ...J K JSXFA Series Port size 06 10 sizes Port size 14 size Dimensions JSXFAE Compression Fitting Type Dimensions mm Dimension in shows the dimension after tightening Model Port size P A B C E F G H J K...

Page 7: ...B A 52 20 Silencer Option F E D C B 2 x P Port size Pilot port 1 8 1 4 Rc NPT G Exhaust port 3 8 20 G D F E Pulse Valve Valve for Dust Collector JSXFA Series Port size 06 10 sizes Port size 14 size D...

Page 8: ...the pilot valve to atmosphere the pressure in the pressure action chamber decreases force pushing the main valve down force pushing the main valve up opening the main valve Because of this the air fl...

Page 9: ...erring to Fig 1 If the valve is assembled in incorrect direction it can cause a malfunction 2 Mount the O ring to the body groove See Fig 2 After mounting of the O ring check if the O ring is fitted p...

Page 10: ...iple board connection Interrupt Operation Function A two time hitting function is adopted to improve the bag filter dusting efficiency Turn ON the DIP switch for two time hitting OFF for one time hitt...

Page 11: ...re differential The maximum pressure differential the difference between the inlet and outlet pressure which is allowed for operation When the outlet pressure is 0 MPa this becomes the maximum oper at...

Page 12: ...e adopted 2 Continuous valve open The valve is for pulse operation Do not open the valve contin uously Since a large amount of air is consumed the dia phragm will oscillate chatter due to insufficient...

Page 13: ...3 Painting and coating Warnings or specifications printed or labeled on the product should not be erased removed or covered up Piping Warning 1 During use deterioration of the tube or damage to the fi...

Page 14: ...losive atmospheres 3 Do not use in locations subject to vibration or impact 4 Do not use in locations where radiated heat will be received from nearby heat sources 5 Employ suitable protective measure...

Page 15: ...ironments outside of the given specifications or use outdoors or in a place exposed to direct sunlight 2 Installation on equipment in conjunction with atomic energy railways air navigation space shipp...

Reviews: