Rotary switch for setting output

Output terminal block

Common terminal block

4 x ø4.5

Power supply terminal block

 Power supply switch

Digital switch for setting OFF time

Digital switch for setting ON time

DIP switch for setting cascade

DIP switch for setting two-time hitting

Terminal block for cascade connection

LED10

LED9

LED8

LED7

COM

FG

AC2

AC1

LED

14

POW

LED

13

IN

LED

12

CAS

LED

11

OUT

LED6

LED5

LED4

LED3

LED2

LED1

1A

ON

OFF

Dimensions

Pressure Terminology

Other

1. Maximum operating pressure differential

The maximum pressure differential (the difference between the 
inlet and outlet pressure) which is allowed for operation. When 
the outlet pressure is 0 MPa, this becomes the maximum oper-
ating pressure.

2. Minimum operating pressure differential

The minimum pressure differential (the difference between the 
inlet pressure and outlet pressure) required to keep the main 
valve fully open.

3. Maximum system pressure

The maximum pressure that can be applied inside the pipe-
lines (line pressure).
[The pressure differential of the solenoid valve portion must 
not exceed the maximum operating pressure differential.]

1. Symbol

In the symbol (

), when the valve is closed, flow is 

blocked from port 1 to port 2. However, if the pressure in port 2 
is higher than port 1, the valve will not be able to block the fluid 
and it will flow from port 2 to port 1.

JSXFA 

Series 

/ Glossary of Terms

10

Dedicated Controller for Operation 

VXFC 

Series

Summary of Contents for JSXFA Series

Page 1: ...s specific testing conditions JSXFA 06 Pilot valve orifice is 5 mm or larger 2 Comparison with SMC existing model Air consumption 35 3 reduction Peak pressure Size 3 4 20A 1 25A 1 1 2 40A Compression...

Page 2: ...or JSXFA Series Easier maintenance Springless diaphragm allows for easy maintenance of valve Main valve and sub valve for 40A included in maintenance kit Flow rate characteristics 40 1 2 increase Opti...

Page 3: ...cing Pulse Valve Filter Header tank Application of the pulse valve Pulse Valve JSXFA Series General production line Mining Steel and cement Pharmaceutical Agriculture livestock Food Pulse blow for var...

Page 4: ...peratures B 40 to 60 C Symbol 2 OUT 1 IN Caution Selection of Pilot Valve For the pilot valve orifice diameter 5 mm or larger is recommended When the pilot orifice diameter is 3 mm or larger and less...

Page 5: ...omated 7 Compression nut ADC 8 Hexagon bolt Stainless steel Component Parts No Description Material 1 Body ADC 2 Main valve Resin 3 O ring NBR 4 Bonnet ADC 5 Hexagon bolt Stainless steel Component Par...

Page 6: ...J K JSXFA Series Port size 06 10 sizes Port size 14 size Dimensions JSXFAE Compression Fitting Type Dimensions mm Dimension in shows the dimension after tightening Model Port size P A B C E F G H J K...

Page 7: ...B A 52 20 Silencer Option F E D C B 2 x P Port size Pilot port 1 8 1 4 Rc NPT G Exhaust port 3 8 20 G D F E Pulse Valve Valve for Dust Collector JSXFA Series Port size 06 10 sizes Port size 14 size D...

Page 8: ...the pilot valve to atmosphere the pressure in the pressure action chamber decreases force pushing the main valve down force pushing the main valve up opening the main valve Because of this the air fl...

Page 9: ...erring to Fig 1 If the valve is assembled in incorrect direction it can cause a malfunction 2 Mount the O ring to the body groove See Fig 2 After mounting of the O ring check if the O ring is fitted p...

Page 10: ...iple board connection Interrupt Operation Function A two time hitting function is adopted to improve the bag filter dusting efficiency Turn ON the DIP switch for two time hitting OFF for one time hitt...

Page 11: ...re differential The maximum pressure differential the difference between the inlet and outlet pressure which is allowed for operation When the outlet pressure is 0 MPa this becomes the maximum oper at...

Page 12: ...e adopted 2 Continuous valve open The valve is for pulse operation Do not open the valve contin uously Since a large amount of air is consumed the dia phragm will oscillate chatter due to insufficient...

Page 13: ...3 Painting and coating Warnings or specifications printed or labeled on the product should not be erased removed or covered up Piping Warning 1 During use deterioration of the tube or damage to the fi...

Page 14: ...losive atmospheres 3 Do not use in locations subject to vibration or impact 4 Do not use in locations where radiated heat will be received from nearby heat sources 5 Employ suitable protective measure...

Page 15: ...ironments outside of the given specifications or use outdoors or in a place exposed to direct sunlight 2 Installation on equipment in conjunction with atomic energy railways air navigation space shipp...

Reviews: