4 Settings 

4.1  Finger Opening/Closing Speed Adjustment  

  Use a flat blade screwdriver for adjusting the metering valves. 

  Ensure that the restriction of the two metering valves is approximately 

the same. If they differ too much, the operation can become unstable.  

 

 

 

 

 

 

 

 

 

 

Figure 5

 

 

5 How to Order 

Refer to the customer drawings

 

for ‘How to Order’. 

6 Outline Dimensions  

Refer to the customer drawings

 

for outline dimensions. 

 

 

7 Maintenance 

7.1  General maintenance 

 Caution 

  Not following proper maintenance procedures could cause the product 

to malfunction and lead to equipment damage. 

  If handled improperly, compressed air can be dangerous. 

  Maintenance  of  pneumatic  systems  should  be  performed  only  by 

qualified personnel. 

  Before performing maintenance, turn off the power supply and be sure 

to  cut  off  the  supply  pressure.  Confirm  that  the  air  is  released  to 
atmosphere. 

  After  installation  and  maintenance,  apply  operating  pressure  and 

power  to  the  equipment  and  perform  appropriate  functional  and 
leakage tests to make sure the equipment is installed correctly. 

  If any electrical connections are disturbed during maintenance, ensure 

they  are  reconnected  correctly  and  safety  checks  are  carried  out  as 
required  to  ensure  continued  compliance  with  applicable  national 
regulations. 

  Do not make any modification to the product. 

  Do  not  disassemble  the  product,  unless  required  by  installation  or 

maintenance instructions. 

 Warning 

  When  air  grippers  are  removed  for  maintenance,  first  confirm  that 

measures are in place to prevent any workpieces from dropping, run-
away  of  equipment.  Then  cut  off  the  supply  pressure  and  electric 
power  and  exhaust  all  compressed  air  from  the  system  using  the 
residual pressure release function. When the equipment is restarted, 
proceed with caution after confirming that appropriate measures are in 
place to prevent cylinders from sudden movement. 

  Do not allow people to enter or place objects in the carrying path of the 

air gripper. Otherwise injury or accident may occur. 

  Do not put hands in between the air gripper fingers or attachments. 

 
 
 
 
 
 

8 Limitations of Use 

8.1  Limited warranty and disclaimer/compliance requirements 

Refer to Handling Precautions for SMC Products. 

9 Product Disposal 

This  product  shall  not  be  disposed  of  as  municipal  waste.  Check  your 
local regulations and guidelines to dispose this product correctly, in order 
to reduce the impact on human health and the environment. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

10 Contacts 

Refer  to  www.smcworld.com  or  www.smc.eu  for  your  local 
distributor/importer. 

 

 

URL :  

https:// www.smcworld.com (Global)      https:// www.smc.eu (Europe) 

SMC Corporation, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, Japan 
Specifications are subject to change without prior notice from the manufacturer.  
© 

2021

 

SMC Corporation All Rights Reserved. 

Template DKP50047-F-085M 

magnified view of the 
matering valve 

Adjustment groove 

(for flat blade screwdriver) 

Reviews: