Sensor head 

Detection hole 

 

6-2.  Detection range 

Electrostatic sensor installation distance and detection range are shown below. 

 
 
 

Installation   

distance mm 

Detection range   

mm 

10 

45 

20 

85 

25 

100 

30 

120 

40 

150 

50 

180 

 
 

Installation   

distance mm 

Detection range   

mm 

25 

100 

30 

120 

40 

150 

50 

180 

60 

205 

70 

225 

75 

235 

 
 

6-3.  Cautions on installation 

When an object other than measured object is installed close to the electrostatic sensor, the 

sensor output can be different from actual value due to the effect of charged potential of installed 
object. Don’t place the object, which is not to be measured, or the sensor head cable around the 
sensor detection hole.      Brackets to fix the sensor shall not be covered with insulation layer such 
as paint or surface treatment.   

When installing the object around the electrostatic sensor,  keep the object which is not to be 

measured apart more than minimum installation interval in the table below. 

 
 

Installation   

distance mm 

Min. installation   

interval mm 

10 

20 

20 

40 

25 

45 

30 

55 

40 

65 

50 

75 

60 

90 

70 

100 

75 

105 

 
 
 

Electrostatic sensor  is affected by electric field or electromagnetic field due to its operation 

principle.

 

If the cable, transmitter, or wireless equipment that carries large amount of current is present by 

the sensor head, correct detection of static electricity could be disabled. 

Avoid using the sensor where those components are present. 

IZD10-110 

IZD10-510 

In

s

tallat

ion 

dis

tanc

e

 

Min. installation interval 

Sensor head 

Object that is not to be measured 

Charged object 

Ins

tal

lat

ion 

di

s

ta

nc

e

 

Detection range 

Detection hole 

Sensor head 

Summary of Contents for IZD10-*10 Series

Page 1: ...L PRODUCT NAME Electrostatic Sensor MODEL IZD10 10 Read this operation manual carefully to understand before installation and operation Pay extra attention on the clause concerning the safety Keep this operation manual available whenever ...

Page 2: ...7 5 1 Electrostatic sensor installation 7 5 1 1 Sensor head installation 7 5 1 2 Installation of the sensor amplifier 8 5 2 Circuitry and wiring chart 9 6 Performance 10 6 1 Output signal 10 6 2 Detection range 11 6 3 Cautions on installation 11 6 4 Timing chart 12 7 Exterior dimensions 12 ...

Page 3: ... Only trained personnel should operate pneumatically operated machinery and equipment Mounting of the sensor and maintenance shall be performed by person with adequate knowledge and experience 3 Do not service machinery equipment or attempt to remove components until safety is confirmed 1 Inspection and maintenance of machinery equipment should only be performed after confirmation of safe locked o...

Page 4: ... amplifier do not receive excess stress Fix the cable as close to the products as possible to avoid bending with acute angle Stressful wiring leads to cause malfunction disconnection and fire Min bend radius Sensor cable 25mm Note Bend radius allowable for fixed wiring at 20o C If bent under 20o C excess stress will be applied to the entry of the cable at the joint part with external part or the s...

Page 5: ...on of sensor electrified potential Warning 1 Ensure adequate electric capacity and voltage satisfying spec value 2 Only connect to SELV circuit type power supplies which have reinforced insulation to the low voltage mains of the building installation SELV according to EN60950 1 3 Ensure safety of wiring and surrounding conditions before supplying power 4 Do not connect remove wiring with power sup...

Page 6: ...ce applies direct vibration or impact to the sensor l Condition where the sensor receive force or weight which deform the sensor 3 Electrostatic sensor is not proof against electrical surges caused by lightning strike Appropriate protection measures should be taken by the users Caution 1 Periodic inspection Periodic inspection is necessary to ensure operation without failure Sensor shall be inspec...

Page 7: ... subject is 25mm The color of the Part A is equal to the sensor head Model IZD10 510 The purpose is to confirm the potential of charged object Therefore the sensor is set so that it Inspect charged potential of high voltage Drawing below shows sensor output voltage when the distance between the sensor and measured subject is 50mm The color of Part A on the sensor head is yellow Relation between th...

Page 8: ...tallation distance See 6 1 6 2 Use two M3 screws for mounting the sensor head prepare separately Recommended tightening torque for M3 screw 0 61 to 0 63Nm Electrostatic sensor model no IZD10 110 IZD10 510 Measuring range 0 4kV when detection distance 25mm 1 20kV when detection distance 50mm 1 Output voltage 1 to 5V Output impedance Approx 100ohms Effective detection distance 10 to 50mm 25 to 75mm ...

Page 9: ...r head breakage or disconnection 5 1 2 Installation of the sensor amplifier Mount the sensor amplifier with two M3 screws prepare separately Recommended tightening torque for M3 screw 0 61 to 0 63Nm Mate M3 bolt to the bolt mount surface Mounting from the opposite side leads to cause the breakage of the sensor amplifier Do not pull the cable out of the sensor amplifier or turn it from the root of ...

Page 10: ...tion or be damaged When the cable for connecting external equipment is cut in short length do not connect the shield line Shield line is common with amplifier case Frame ground shall be prepared with the amplifier case side 2 Wiring chart Lead wire cover color Meaning Function Brown DC Power source DC24V Blue DC Power source 0V White Sensor output 1 to 5V analog output IN Shield Sensor head case E...

Page 11: ...atic sensor 0 1 2 3 4 5 6 0 8 0 6 0 4 0 2 0 0 0 2 0 4 0 6 0 8 Relation between sensor output and charged potential on installation distance IZD10 110 Sensor output voltage V Charged potential kV From the steepest line 10mm 20mm 25mm 30mm 40mm 50mm of installation distance Installation distance 50mm Installation distance 10mm Relation between sensor output and charged potential on installation dist...

Page 12: ...ot be covered with insulation layer such as paint or surface treatment When installing the object around the electrostatic sensor keep the object which is not to be measured apart more than minimum installation interval in the table below Installation distance mm Min installation interval mm 10 20 20 40 25 45 30 55 40 65 50 75 60 90 70 100 75 105 Electrostatic sensor is affected by electric field ...

Page 13: ...be unstable It is recommended to wait for 10min or longer for start operation Note 2 The case of IZD10 110 Value in shows the case of IZD10 510 7 Exterior dimensions Common in IZD10 110 and IZD10 510 Color of Part A IZD10 110 The same color as sensor head IZD10 510 Yellow Charged Potential Note2 Sensor output Power source DC24V 100ms or less Output delay 100ms or less Output delay Time until opera...

Reviews: