Summary of Contents for ITV1000-DE Series

Page 1: ...EL Series Product Number ITV1000 2000 3000 2090 DE Series Install and operate the product only after reading the Operation Manual carefully and understanding its contents Specifically read the safety...

Page 2: ...ns P2 Handling precautions P4 Wiring method and LED indication P6 System configuration P7 Communication specification P7 Setting of dipswitch P8 Pressure setting and output monitoring P10 Communicatio...

Page 3: ...f equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly...

Page 4: ...responsibility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the...

Page 5: ...oduct is interrupted or shut off while the power is still on the internal solenoid valve will continue to operate and a humming noise will be generated Turn off the power supply when supply pressure i...

Page 6: ...ling this product and its wiring away from strong electric fields such as those of motors and power cables etc 3 Be sure to implement protective measures against load surge for inductive loads solenoi...

Page 7: ...nds the use of our company PCA 1557633 socket type The line color is when the optional cable is used Connection to external equipment LED indication Item Turning ON Turning OFF Blinking POWER Power ON...

Page 8: ...ifications Remarks Field bus DeviceNetTM Volume1 Edition3 8 Volume3 Edition1 5 EDS file ITV A EDS Down load from Web Slave type Group 2 Only Device type 00h Generic Device MAC ID 0 to 63 Due to the di...

Page 9: ...and reset if necessary Setting procedure Loosen the screws of the switch cover Open the cover from the bottom upwards See drawing Set switches according to the following procedure After setting the sw...

Page 10: ...clear the output pressure when the DeviceNetTM line causes a communication error due to disconnection Setting 9 Function Hold ON Hold the output pressure Clear OFF Exhaust the output pressure When swi...

Page 11: ...command sending and receiving data Item Output from PLC Poll request Input to PLC Poll response Data size 2Byte 16bit 2Byte 16bit Communication data b15 b14 b1 b0 b15 b14 b1 b0 The I O data occupies t...

Page 12: ...cover Use a soft cloth to remove stains Refer to the SMC website URL http www smcworld com for more information about troubleshooting This operation manual refers to all standard types and is partiall...