No.PS

※※

-OMJ0004-E 

 

 

 

Reference 

No. 

Problem 

Possible cause 

Investigation method 

Countermeasure 

An over 

current error 
(Er1) is 
displayed. 

 

A system 

error (Er4, 6, 
7, 8) is 
displayed. 

 

The display 

shows 
"HHH". 

 

The display 

shows "LLL". 

 

A residual 

pressure 
error (Er3) is 
displayed. 

Over current to 
the output 
(Er1) 

1. Check if a current of 80 mA or more 

is flowing to the output. 

2. Check whether the connected load 

is as specified, and confirm that 
there is no short circuit in the load. 

3. Check if a relay without a surge 

voltage suppressor is connected. 

4. Check if the wiring is in the same 

route as (or bundled together with) 
the high-voltage line or power line. 

1. 2. Connect the load as 

specified. 

3. Change to a relay with a 

surge voltage suppressor or 
take measures to prevent 
noise. 

4. Separate the wiring from the 

high voltage line and power 
line. 

Improper 
transaction of 
the internal 
data of the 
Pressure 
switch 
(Er4, 6, 7, 8) 

1. Confirm that there is no possibility 

of noise interference, such as static 
electricity. 

2. Confirm that the power supply 

voltage is in the range of 12 to 24 
VDC

10%. 

1. Remove the noise source or 

take measures to prevent 
noise interference and turn off 
the power supply. Then, turn 
the power supply on again. 

2. Supply an operating voltage 

of 12 to 24 VDC

10%. 

Applied 
pressure over 
the upper limit 
(HHH) 

1. Confirm that the pressure is not 

over the upper limit of the set 
pressure range. 

2. Check if moisture such as water 

droplets has entered the inside of 
the piping. 

1. Return the pressure to within 

the set pressure range.   

2. Take measures to prevent 

moisture from entering the 
piping. 

Applied 
pressure under 
the lower limit 
(LLL) 

1. Confirm that the pressure is not 

over the upper limit of the set 
pressure range. 

2. Confirm if the moisture such as 

water drop has entered the inside 
of the piping. 

1. Return the pressure within 

the set pressure range.   

2. Take the measure to prevent 

the moisture from entering to 
the piping. 

The pressure is 
not atmospheric 
pressure for zero 
clear operation 
(Er3) 

Check if the pressure difference is 
more than ±10%F.S. from 
atmospheric pressure (±0.11 MPa or 
more) when the zero clear operation 
is performed. 

Return the applied pressure to 
atmospheric pressure and retry 
the zero clear operation. 

Product failure 

 

Replace the product. 

The values in 
the display 
fluctuate. 

Incorrect 
power supply 

Confirm that the power supply voltage is 
within the range of 12 to 24 VDC 

10%. 

Supply a power supply voltage 
of 12 to 24 VDC 

10%. 

Incorrect wiring 

Check the wiring to the power supply. 
Confirm that the brown and blue wires 
are connected to DC(+) and DC(-) 
respectively, and that the output line 
has not come off (contact failure). 

Correct the wiring. 

Factory 
pressure 
change 

Check if the factory pressure has 
changed. 

If the fluctuation is worrisome, 
consider that a change in the 
response time correspondingly 
increases the interval for 
updating the display, and set 
the response time longer. 

Summary of Contents for ISE35

Page 1: ...No PS OMJ0004 E PRODUCT NAME Digital Pressure Switch MODEL Series Product Number ISE35...

Page 2: ...Identification and How to Order 8 Summary of Product parts 9 Mounting and Installation 10 Wiring 10 Pressure Setting 11 Setting of Function 12 Default setting 12 Other Settings 22 Maintenance 25 Trou...

Page 3: ...equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly T...

Page 4: ...the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excl...

Page 5: ...ful fluids Fire malfunction or damage to the product can result Verify the specifications before use Do not operate in an atmosphere containing flammable or explosive gases Fire or an explosion can re...

Page 6: ...damage or malfunction of the Pressure switch Verify the specifications carefully before use Do not use the Pressure switch for compressed air containing plenty of condensed water Otherwise it can caus...

Page 7: ...e switch can be contaminated with noise or induced surge voltage from the power or high voltage line causing malfunction Lay the wires to the Pressure switch to a wire duct or in a protective tube oth...

Page 8: ...he Pressure switch Do not press the set buttons with a sharp pointed object It can cause damage to the set buttons Warm up for 20 to 30 minutes for the detection of low pressure The indication drifts...

Page 9: ...8 No PS OMJ0004 E Model Identification and How to Order Made to Order AR AW D Series Mounting kit is included An adapter O ring lock pin and two mounting screws are attached...

Page 10: ...mode and error code Four display modes can be selected display always in red or green only or switch from green to red or red to green linking to output button Increases the mode and ON OFF set value...

Page 11: ...duct or by using a series power supply instead of a switch mode power supply Connector Connecting Disconnecting When connecting the connector insert it straight onto the pin holding the lever and conn...

Page 12: ...ow does not cause any problem keep this setting How to perform 1 Press the button in the measurement mode to display set values 2 Press the or button to change the set value The button is for increase...

Page 13: ...page 15 1 s Operation mode Selects the mode to operate the Pressure switch page 15 Hysteresis mode Hysteresis page 17 0 01 MPa 1 psi Output type Sets the method to generate the switch output page 17...

Page 14: ...asurement mode The mode in which the pressure is detected and displayed and the switch function is operating This is the basic operating mode other modes should be selected for set point And other fun...

Page 15: ...to select the necessity of switch output 3 Keep pressing the button for 2 seconds or longer after selection is completed Then the setting is finished and the measurement mode returns 2 Indication col...

Page 16: ...elect the response time 3 Keep pressing the button for 2 seconds or longer after selection is completed Then the setting is finished and the measurement mode returns 4 Operation mode The switch operat...

Page 17: ...increase and the button is for decrease Press the button once to increase by one figure and press it continuously to keep set figure increased Press the button once to decrease by one figure and press...

Page 18: ...reased 3 Keep pressing the button for 2 seconds or longer after selection is completed Then the setting is finished and the measurement mode returns 6 Output type A desired output mode can be set free...

Page 19: ...s again only in the measurement mode The display in power saving mode is as shown on right figure 8 Secret code input The necessity of secret code input for key lock can be selected How to perform 1 K...

Page 20: ...19 No PS OMJ0004 E List of output mode If the point where the switch output is changed comes outside of set pressure range due to the change of set pressure hysteresis H is automatically compensated...

Page 21: ...ds or longer in the measurement mode After is indicated press button eight times Then and current setting appears in turn 2 Press the or button to select the indication mode 3 Keep pressing the button...

Page 22: ...a 0 01 Kgf cm2 0 1 bar 0 1 psi 1 How to perform 1 Press the button three times in the measurement mode and current setting appears in turn 2 Press the or button to select the indication unit 3 Press t...

Page 23: ...second or longer while the pressure is being held the maximum minimum value is initialized Zero clear A displayed value can be adjusted to zero when the pressure to be measured is within 10 F S of th...

Page 24: ...button to select unlocking of the key 3 When the button is pressed the input of secret code is asked For how to input the secret code refer to How to input and change the secret code on page 24 4 If i...

Page 25: ...nput and change the secret code Changed secret code is indicated 3 After check it is as desired press the button The measurement mode returns At this time if the or button is pressed changed secret co...

Page 26: ...accurate control wait until it has warmed up Approximate 20 to 30 minutes Mounting regulator Cut the power supply to the Pressure switch when assembling Also turn the set pressure of the regulator to...

Page 27: ...with SMC separately to obtain countermeasures Yes No The pressure switch does not operate normally Refer to reference No 1 The switch output is on Go to A The indicator light is on The indicator light...

Page 28: ...isplay is reversed Refer to reference No 7 The display is abnormal Refer to reference No 8 Refer to reference No 8 Refer to reference No 10 Refer to reference No 13 Refer to reference No 12 Refer to r...

Page 29: ...rform the pressure setting 2 Perform the functional setting Wrong setting Selection of without switch output Check if it can be set so that the switch output can be used Perform the functional setting...

Page 30: ...pper limit of the set pressure range 2 Check if moisture such as water droplets has entered the inside of the piping 1 Return the pressure to within the set pressure range 2 Take measures to prevent m...

Page 31: ...play is inverted Selection of unsuitable model Selection of wrong electrical entry Check the part number for the electrical entry Review the selected model Change of indication mode Check the selected...

Page 32: ...properly 2 Confirm that the Pressure switch is installed to the mounting adapter properly Correct the mounting conditions Product failure Replace the product 15 Noise Air leakage Check for air leakage...

Page 33: ...measurement mode 1 digit of the zero clear range varies with individual product differences Perform zero clear operation again after restoring the applied pressure to an atmospheric pressure conditio...

Page 34: ...s 80 mA load current Response time Chattering proof function 1 s 0 25 0 5 2 3 selectable Short circuit protection Provided Repeatability 1 F S Hysteresis Hysteresis mode Variable from 0 Window compara...

Page 35: ...34 No PS OMJ0004 E Dimensions...

Page 36: ...everal places July 2018 E Contents are added October 2019 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subj...

Reviews: