Piping

 

 

Warning 

(1)  Before  piping  is  connected,  it  should  be  thoroughly  blown  out  with  air  (flushing)  or  washed  to 

remove chips, cutting oil and solid foreign material from inside the pipe. Contamination of piping 
may cause damage or malfunction. 

(2)  When  screwing  together  pipes  and  fittings,  etc.,  be  certain  that  chips  from  the  pipe  threads  and 

sealant  do  not  get  inside  the  pipe.  Contamination  of  piping  may  cause  damage  or  malfunction. 
When a sealant tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads. 

(3)  Connect piping/fittings using the recommended torque while holding the female thread side tightly. 

Insufficient  tightening  torque  leads  to  cause  of  loosening  or  sealing  failure,  and  excessive 
tightening torque leads to cause of breakage of screws. Tightening without holding female thread 
applies an excessive force to the piping bracket directly, leading to breakage. 
 
 
 
 

 

(4)  Do not apply a spanner to the pressure switch body during piping. Otherwise, the product may be 

damaged. 

 
 
 
 
 
 
 
 
 
 
 
 

(5)  Do not apply torsion or bending moment other than the weight of the product itself. External piping 

needs to be supported separately as it may cause breakage. Non-flexible piping like steel tube is 
susceptible to excessive moment load or vibration. Insert flexible tubes to prevent this. 

 

Air Source 

Warning 

(1)  Use  clean  air.  Do  not  use  compressed  air  containing  chemicals,  organic  solvent,  synthetic  oil  or 

corrosive gas as it may be cause of breakage of components or operation failure. 

(2)  Air containing too much moisture may cause malfunction. Install an air drier or aftercooler before 

the product.   

 

Operating Environment

 

 

Warning 

(1)  This product uses a reed switch.

 

Therefore, the product may malfunction in a magnetic field.    Do 

not use the product where it is affected by magnetism.   

(2)  This product is not hermetic.    Therefore, avoid installation in a place where it is exposed to water 

and  oil  entering  into  the  product,  causing  malfunction  and  damage  due  to  corrosion  of  the 
electrical circuit.    Do not use the product in a place where the product could be splashed by water 
or oil. 

Pressure switch 

Recommended tightening torque Unit: N m

Thread size

1/8

1/4

3/8

1/2

3/4

1

1 1/4

1 1/2

Torque

7 to 9

12 to 14 22 to 24 28 to 30 28 to 30 36 to 38 40 to 42 48 to 50

-5- 

Summary of Contents for IS10E-20-D

Page 1: ...tch with T Spacer Pressure Switch with L Piping Adapter Pressure Switch with Piping Adapter MODEL Series Product Number IS10M 20 30 40 50 60 1 6 L P Z D IS10T 20 30 40 50 60 F N 6 L P Z D IS10L 20 30...

Page 2: ...3 Standard Specifications 8 9 4 Electric circuit 10 5 Relation between Pressure setting and operating pressure 10 6 How to Order 11 14 7 Structural Drawing 15 8 Type of scale 15 9 Pressure Setting Me...

Page 3: ...failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembl...

Page 4: ...the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this...

Page 5: ...the product after carefully reading and understanding the operation manual 2 Do not drop or apply impact during transportation or installation It will cause damage to the product or operation failure...

Page 6: ...ing moment other than the weight of the product itself External piping needs to be supported separately as it may cause breakage Non flexible piping like steel tube is susceptible to excessive moment...

Page 7: ...ct protection box connect the lead wire indicating SWITCH on the contact protection box and the lead wire from the switch The lead length between the switch body and the contact protection box should...

Page 8: ...pplied to this product and that electrical cables are disconnected before performing maintenance 6 After maintenance confirm that the product satisfies specific functions and no external leakage occur...

Page 9: ...x operating current Switch Characteristics Hysteresis Air 5 to 60 o C with no freezing 1 0MPa 0 7MPa 0 1MPa to 0 4MPa 24VAC DC or less 50mA 48VAC DC or less 40mA 100VAC DC or less 20mA Equivalent to I...

Page 10: ...ess 50mA 48VAC DC or less 40mA 100VAC DC or less 20mA Equivalent to IP40 Model Max operating pressure Hysteresis Switch Characteristics Max operating current IS10E 20 D IS10E 30 D IS10E 40 D IS10E 50...

Page 11: ...ic circuit 5 Relation between Pressure setting and operating pressure 10 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 1 0 2 0 3 0 4 0 5 0 6 Operating pressure MPa Set pressure scale MPa ON pressure OFF pressure Hy...

Page 12: ...e selected alphabetically a to d Note 2 Set pressure range of 6 psi 0 2 to 0 6 MPa 30 to 90 psi Note 3 Smaller face to face type cannot be mounted on the spacer with the bracket at both ends Mount a s...

Page 13: ...Nil 0 5 3 Z 5 Nil MPa P MPa psi dual scale Note 1 A semi standard product can be selected alphabetically a to c Note 2 Set pressure range of 6P is 0 2 to 0 6MPa 30 to 90psi 3 4 Semi standard a Set pre...

Page 14: ...il MPa P MPa psi dual scale Nil R Note 1 A semi standard product can be selected alphabetically a to d Note 2 Set pressure range of 6P is 0 2 to 0 6MPa 30 to 90psi a Set pressure range b Lead wire len...

Page 15: ...MPa P MPa psi dual scale Nil R Note 1 A semi standard product can be selected alphabetically a to d Note 2 Set pressure range of 6P is 0 2 to 0 6MPa 30 to 90psi a Set pressure range b Lead wire length...

Page 16: ...usting screw Indicator Scale plate Lead wire Body Air flow PRESSURE SWITCH WITH T SPACER IS10T 20 D to IS10T 60 D IS10M 20 1 D to IS10M 60 1 D Air flow PRESSURE SWITCH WITH L PIPING ADAPTER IS10L 20 D...

Page 17: ...ating the adjustment screw and setting the indicator to the figure on the scale Set pressure increases by rotating the adjustment screw clockwise Use a screwdriver of a size suitable for the groove of...

Page 18: ...ssure 2 The lead wire cover has gouges or cracks 1 The lead wire has repeatedly been subject to bending or tensile force 1 Overcurrent was applied to the switch 1 Excessive impact has been applied to...

Page 19: ...ld source provide a shield plate between the pressure switch and the source 1 1 Decrease the impact or use a solid state auto switch 5 The contact protection box has not been used The operating condit...

Page 20: ...D 28 77 6 60 1 42 31 85 6 64 1 53 39 93 6 68 1 71 47 96 6 69 6 71 62 106 6 74 6 90 Model IS10M 20 D IS10M 30 D IS10M 40 D IS10M 50 D IS10M 60 D A B C D 10 6 83 8 66 3 42 12 6 91 8 70 3 53 14 6 97 8 7...

Page 21: ...4 3 8 31 85 6 64 1 53 1 4 3 8 1 2 39 93 6 68 1 71 1 4 3 8 1 2 3 4 47 96 6 69 6 71 3 8 1 2 3 4 62 106 6 74 6 90 Model IS10 20 D IS10 30 D IS10 40 D IS10 50 D IS10 60 D Port size A B C D 1 8 1 4 28 77...

Page 22: ...D 21 Port size A B C D E F 1 8 1 4 3 8 24 77 8 60 3 42 24 1 4 3 8 1 2 27 85 8 64 3 53 30 1 4 3 8 1 2 3 4 30 93 8 68 3 71 36 3 4 36 1 46 3 4 39 46 1 1 4 1 1 2 42 63 9 5 106 8 74 8 90 31 96 8 69 8 71 8...

Page 23: ...cover Oct 2021 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any...

Reviews: