SMC Networks IDFS Series Manual Download Page 1

CAT.EX30-1

Stainless Steel Heat 

Exchanger Type Air Dryer

Series  

IDUS/IDFS

 

(220/240VAC 50Hz)

A

Improved corrosion resistance with the use 
of stainless steel heat exchanger

Standard evaporation thermometer 
facilitates daily inspection 

Compac heat exchanger reduces overall 
dimensions of the air dryer

Environmentally friendly refrigerant  R134a

Series IDUS

Series IDUS

475

(430)

230

(275)

IDUS6E

703

(640)

280

(295)

740

275

225

IDUS3E

295

(300)

165

(189)

IDUS4E

(   ): Previous model IDU3D/4D/6D

Model

Air flow

capacity

l

/mim(ANR)

Power 

consumption W

Inlet air

temperature 

°

C

310

55

60

55

60

500

160

Series IDFS 

Series IDFS 

IDFS6E

614

(640)

170

(259)

IDFS8E

996

(850)

240

(292)

IDFS11E

1370

(1300)

295

(337)

(   ): Previous model IDF6D/8D/11D

Model

Air flow

capacity

l

/mim(ANR)

Power

consumption W

740

35

40

35

40

1200

1650

160

285

230

Inlet air

temperature 

°

C

Approved

IDUS/IDFS  5/23/02 2:18 PM  Page 1

Summary of Contents for IDFS Series

Page 1: ...erant R134a Series IDUS Series IDUS 475 430 230 275 IDUS6E 703 640 280 295 740 275 225 IDUS3E 295 300 165 189 IDUS4E Previous model IDU3D 4D 6D Model Air flow capacity l mim ANR Power consumption W In...

Page 2: ...467 l min ANR with a 50Hz power supply according to data D 1 Note l min ANR is for reference conditions of 20 C 1 ATM and 65 relative humidity Condition Condition 30 32 35 40 80 5 0 59 0 56 0 54 0 50...

Page 3: ...Order Note 1 All the options are not currently available Please contact SMC if necessary Note 2 Refer to page 7 for further information of options Note 3 Combination of L and M is not available With h...

Page 4: ...Circuit breaker Note 3 Note 1 Select an air dryer according to the selection method and note the rated conditions Note 2 The data for l min ANR refers to the conditions of 20 C 1 atm pressure and rela...

Page 5: ...7 325 H K 330 330 355 L 315 315 315 M 380 470 515 J J K A B D E M Note The diagram above is drawn base on IDUS3E dimension with scale 1 6 Evaporation thermometer Illumination switch Draft air outlet P...

Page 6: ...Order Note 1 All the options are not currently available Please contact SMC if necessary Note 2 Refer to page 7 for further information of options Note 3 Combination of L and M is not available With...

Page 7: ...1 Select an air dryer according to the selection method and note the rated conditions Note 2 The data for l min ANR refers to the conditions of 20 C 1 atm pressure and relative humidity of 65 Note 3 I...

Page 8: ...575 350 440 485 297 297 325 H K 330 330 355 L 315 315 315 M 380 470 515 J J K A B D E M Note The diagram above is drawn base on IDFS6E dimension with scale 1 6 Evaporation thermometer Illumination swi...

Page 9: ...nger or around electrical parts where operation may be affected by coating This option changes the float style auto drain AD44 used by standard air dryers to a motor operated auto drain ADM200 04 wher...

Page 10: ...50 60 60 50 60 50 40 30 40 30 20 10 20 10 0 10 20 30 1 5MPa 1 3MPa 1 1MPa 0 9MPa 0 7MPa 0 5MPa 0 3MPa 0 1MPa Atmospheric pressure A tm o s p h e ri c p re s s u re Example If air at 30 C and 60 humid...

Page 11: ...hould continuously review the suitability of all items specified Referring to the latest catalogue information with a view to giving due consideration to any possibility of equipment failure when conf...

Page 12: ...ce Caution 1 Do not allow flow greater than the rated flow rate If the flow exceeds the rated flow rate even momentarily this can cause drainage and oil to be sprayed downstream or cause damage etc 2...

Page 13: ...vibration Check the specifications for each series 6 Locations with high moisture and dust Contact SMC in ad vance 2 Adhere to the fluid and ambient temperature ranges The fluid and ambient temperatu...

Page 14: ...ions may cause condensate to form on the surface of the outlet piping Roll thermal insulation around piping to prevent condensate from forming Vibration caused by the compressor should not be transmit...

Page 15: ...it will be activated the operating light goes off and the dryer will not be activated Please wait three minutes Caution Caution Caution Caution Caution When the air dryer is operated under the followi...

Page 16: ...RALIA SMC Pneumatics Australia Pty Ltd NEW ZEALAND SMC Pneumatics N Z Ltd EUROPE AUSTRIA SMC Pneumatik GmbH CZECH SMC Industrial Automation CZ s r o DENMARK SMC Pneumatik A S FINLAND SMC Pneumatics Fi...

Reviews: