IDX-OM-U010
Chapter 7 References
7.2
Refrigerant with GWP reference
IDFC60/70/80/90 Series
7-2
Note 5: Products other than Option R are not equipped with an earth leakage breaker. Purchase
an appropriate earth leakage breaker separately. Use an earth leakage breaker with a leak
current sensitivity of 30mA.
Note 6: This value specified by IPCC4 AR4. The value specified by the Revised Fluorocarbons
Recovery and Destruction Law (Japanese law) is R410A GWP: 2090.
Note 7: The maximum operating pressure is 1.0MPa as standard, but it is possible to achieve
1.6MPa when selecting Option L.
Correction factor
Inlet air temperature
o
C
35
40
45
50
55
60
65
1.58
1.46
1.09
1.00
0.79
0.64
0.51
Inlet air pressure MPa
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0.67
0.79
0.88
0.91
1.00
1.02
1.04
1.09
Ambient temperature
o
C
20
25
30
35
40
45
1.19
1.13
1.06
1.00
0.90
0.77
Calculation example: The air flow capacity when the dew point of the IDFC60 is set to 10
o
C
under the following conditions is calculated. [Operating conditions: Inlet air temperature: 45
o
C,
Ambient temperature: 30
o
C, Inlet air pressure: 0.8 MPa]
2.8 m
3
/min ×1.09 × 1.06 × 1.02
=
3.3 m
3
/min
7.2 Refrigerant with GWP reference
Refrigerant
Global Warming Potential (GWP)
Regulation (EU) No 517/2014
(Based on the IPCC AR4)
Revised Fluorocarbons Recovery
and Destruction Law
(Japanese law)
R410A
2,088
2,090
Note 1: This product is hermetically sealed and contains fluorinated greenhouse gases.
Note 2: See specification table for refrigerant used in the product.