Option V
Option V is a dryer with a timer controlled solenoid valve type auto drain. The timer is adjusted by
customer according to the operating conditions.
12.1 Safety instructions for use
Refer to the instructions below when handling the product.
WARNING
- Before replacing the auto drain on the compressed air side confirm that the pressure gauge
indicates zero
”.
Removing the auto drain with any air pressure remains could arise to unexpected accident,
such as parts been expelled when being unscrewed.
- There is the possibility of damaging the condenser during the auto drain maintenance. -
Follow end-user procedures to ensure safety of operator.
(example: Put on protective glass, apron, and gloves).
12.2 Specifications
Part number (Service parts)
IDF-S0534
Max. operating pressure
232psi(1.6MPa)
ON time
Setting range
Approx. 0.5 to 10sec.
OFF time
Setting range
Approx. 0.5 to 5 min.
With a timer controlled solenoid
valve type auto drain
(O.D. 10m)
Drain tube
(O.D 12mm)