5.4 Basic setting mode
HRR Series
5-12
5.4 Basic setting mode
5.4.1 Screen configuration
The screen of this product shows "basic setting mode" and " advanced
setting mode".
In "basic setting mode", only temperature can be set.
Other settings are done in " advanced setting mode".
"Basic setting mode" consists of the following menu.
・
Main menu
・
Alarm display menu
・
Notice for
maintenance menu
5.4.2 Main menu
The display on the main screen is as follows.
Current discharge temperature of circulating fluid (Main menu
TOP screen)
1.
Turn ON the power supply switch.
Current temperature and set temperature are displayed on the digital display.
Alarm display screen (See
5.4.3
) appears when an alarm is generated.
Circulating fluid temperature
setting
2.
Press the [ENT] key, the set temperature will blink and the set value can be changed.
Change the set temperature by pressing the [
▼][▲] key.
After changing the set temperature, set it by pressing the [ENT] key.
After setting the value, blinking will end.
Circulating fluid return temperature Diaplay
3.
Press the [▼] key.
The return temperature of the circulating fluid is displayed on the digital display.
Circulating fluid discharge pressure display
4.
Press the [▼] key.
The discharge pressure of the circulating fluid is displayed on the digital display.
℃
RUN
℃
RUN
MPa
RUN
Set Temperature
Circulating fluid
return temperature
Current discharge temperature
RETt
⇒
tTEMP
(
alternately displayed
)
Circulating fluid discharge pressure