background image

 

FS-8700-130 Notifier NCA2-NFS2-3030 Manual 

Page 22 of 23 

System Trouble         

Address 

 

System Trouble         

Address 

LOOP CONTINUITY TEST FAIL LOOP 2            230 

 

INCOMPATIBLE SOFTWARE OR INVALID CBE        

484 

LOOP CONTINUITY TEST FAIL LOOP 3            231 

 

WALK TEST - FIRE PROTECTION IS LIMITED      

485 

LOOP CONTINUITY TEST FAIL LOOP 4            232 

 

REMOTE PROG MODE ACCESSED                   

486 

LOOP CONTINUITY TEST FAIL LOOP 5            233 

 

DIA PROG. CHANGE DET. SERVICE REQUIRED      

487 

LOOP CONTINUITY TEST FAIL LOOP 6            234 

 

ISIB DATA MESSAGE RECEIVED ERROR            

488 

LOOP CONTINUITY TEST FAIL LOOP 7            235 

 

ISIB EXECUTIVE ROUTINE RE-ENTERED           

489 

LOOP CONTINUITY TEST FAIL LOOP 8            236 

 

DIB TO SIB CABLE BAD OR MISSING             

490 

LOOP CONTINUITY TEST FAIL LOOP 9            237 

 

UPLOAD/DOWNLOAD MESSAGE RECEIVED            

491 

LOOP CONTINUITY TEST FAIL LOOP 10           

238 

 

GLOBAL DATABASE MISMATCH                    

492 

AMP FAIL                                    

239 

 

SIB PROG. CHANGE DET. SERVICE REQUIRED      

493 

AC FAIL                                     

240 

 

HS-NCM SNIFFER MODE ACTIVE                  

494 

SCB ASSEM. COM. VERIFIED FAILED             241 

 

EXCEEDED CONNECTION LIMIT                   

495 

8255 PORT CHIP CONTROL WORD CHECK 
FAILE     

242 

 

NAM CCBE. PROG LOST                         

496 

NETWORK  COMMUNICATION  LINK  FAIL 
PORT A      

243 

 

MEMORY LOSS                                 

497 

NETWORK  COMMUNICATION  LINK  FAIL 
PORT B      

244 

 

DVC COMM LOSS                               

498 

STYLE 4 SHORT A L1                          

245 

 

A.C. POWER LOSS. BACK UP ACTIVATED          

499 

STYLE 4 SHORT B L1                          

246 

 

BUZZER OFF-LINE                             

500 

STYLE 4 SHORT A L2                          

247 

 

PANEL DOOR OPEN                             

501 

STYLE 4 SHORT B L2                          

248 

 

OFF NETWORK                                 

502 

STYLE 4 SHORT A L3                          

249 

 

INSTALL. ERROR                              

503 

STYLE 4 SHORT B L3                          

250 

 

OR AUDIO/TELEPHON                           

504 

STYLE 4 SHORT A L4                          

251 

 

EXPANDER MODULES                            

505 

STYLE 4 SHORT B L4                          

252 

 

MANUAL CONTROL                              

506 

STYLE 4 SHORT A L5                          

253 

 

CAT. COMM. FAULT                            

507 

STYLE 4 SHORT B L5                          

254 

 

UNKNOWN                                     

508 

Appendix C.3. Error Messages 

Most error messages are associated with errors in parsing an incoming message from the  Notifier panel.  
The most likely cause is a mismatch in expected message format.  The driver will flag one of the following 
error  messages  and  continue.    In  most  cases  the  message  currently  being  processed  by  the  driver  will 
also be printed so that any problems can be easily diagnosed. 

Two screens ‘System Errors’ and ‘Driver Messages’ exist for displaying errors. 

The System Error Screen  displays the  error number  and the  Driver messages screen displays the  error 
number, description and the message received from the NCA/NCA2 Panel. 

In debug mode the System Error screen will also include Driver messages.  

The following Error Messages appear upon the ‘System Errors’ Screen 

 

%d means numeric number 

 

%s means string 

 Messages number 1, 3, 4 and 5 will be displayed just once if generated after rebooting or power cycling 
the FieldServer. 

 

 

 

 

Summary of Contents for FieldServer FS-8700-130

Page 1: ...03 Document Revision 0 FieldServer FS 8700 130 Notifier NCA2 NFS2 3030 Driver Manual Supplement to the FieldServer Instruction Manual APPLICABILITY EFFECTIVITY Effective for all systems manufactured...

Page 2: ...k you for purchasing the FieldServer Please call us for Technical support of the FieldServer product Contact Information Sierra Monitor Corporation 1991 Tarob Court Milpitas CA 95035 Contact number 1...

Page 3: ...r Parameters 12 5 4 1 FieldServer Related Map Descriptor Parameters 12 5 4 2 Driver Related Map Descriptor Parameters 12 5 4 3 Map Descriptor Example Standard example 13 Configuring the FieldServer as...

Page 4: ...cy and timeliness of the stored data is limited to the frequency of update messages that the Notifier Fire Panel issues If a networked panel does not send the CLEARED message for latched points via th...

Page 5: ...s FieldServer FieldServer Part 8917 16 Pigtail for RJ45 Port RJ45 Connection to TB5 Printer Port Notifier NCA2 NFS2 3030 Connect to one of the RS 232 Ports on the FieldServer P1 CTX CRX REF PTX PRX RE...

Page 6: ...dware Connection Tips Hints The FieldServer should preferably be connected to the TB5 Printer port It is theoretically possible to connect to the TB5 CRT port but this has not been fully tested The Pa...

Page 7: ...ta Array Up to 15 alphanumeric characters Data_Array_Format Provide data format Each Data Array can only take on one format FLOAT BIT UInt16 SInt16 Byte Packed_Byte Swapped_Byte Data_Array_Length Numb...

Page 8: ...ng the FieldServer to receive information from a Notifier Panel 5 1 Panel Status Memory Mapping The primary purpose of this driver is to record the status of devices connected to the Notifier panel by...

Page 9: ...s 1 159 Parameter Addresses For each Node Memory Type Node_Trouble Troubles Faults 1 508 Memory Type Panel Panel Maximum12 Boards and 8 Panel circuits per Board Hardware address memory address Board 1...

Page 10: ...rate CRT Port 4800 9600 19200 38400 57600 Vendor limitation Printer Port 9600 Vendor limitation Parity Specify parity None Vendor limitation Data_Bits Specify data bits 8 Vendor limitation Stop_Bits S...

Page 11: ...ce is connected to the FieldServer P1 P8 Node_Inactivity_Timeout Used to monitor the connection to the panel for inactivity Should there be no response from the panel for the set number of seconds the...

Page 12: ...m One of the Node names specified in Section 5 3 Data_Type Specify memory area type Detector Module Detector_Trouble Module_Trouble Panel Panel_Trouble Bell_Trouble Node_Trouble Address Starting addre...

Page 13: ...NODE2 Panel 1 1056 SMD_N2_PANEL_T DA_N2_PANEL_T 0 Passive NODE2 Panel_Trouble 1 96 SMD_N2_BELL_T DA_N2_BELL_T 0 Passive NODE2 Bell_Trouble 1 4 SMD_N2L01D DA_N2L01D 0 Passive NODE2 1 Detector 1 1749 S...

Page 14: ...FS 8700 130 Notifier NCA2 NFS2 3030 Manual Page 14 of 23 CONFIGURING THE FIELDSERVER AS A NOTIFIER NCA2 NFS2 3030 6 SERVER This driver cannot be configured as a Server...

Page 15: ...hronize the FieldServer with the panel connect the running FieldServer and press the System Reset button on the panel All current events will be re sent to the FieldServer The port must be enabled on...

Page 16: ...any action on receiving a SYSTEM RESET Normally when a Node initiates SYSTEM RESET by pressing the RESET button on the Panel the panel sends an individual CLEAR message for every point it clears in it...

Page 17: ...states 1 0 SUPERVISORY CLEARED SUPERVISORY states 1 0 TROUBLE FAULT CLEARED TROUBLE FAULT States counter DISABLED CLEARED DISABLED states 1 0 PREALARM CLEARED PREALARM states 1 0 ACTIVE CLEARED ACTIVE...

Page 18: ...OARD 7 278 STYLE 6 POS LOOP 2 25 COMM FAULT LOOP INTERFACE BOARD 8 279 STYLE 6 POS LOOP 3 26 COMM FAULT LOOP INTERFACE BOARD 9 280 STYLE 6 POS LOOP 4 27 COMM FAULT LOOP INTERFACE BOARD 10 281 STYLE 6...

Page 19: ...MANY DEVICES ON LOOP 3 338 REMOTE DISPLAY 5 TROUBLE 85 TOO MANY DEVICES ON LOOP 4 339 REMOTE DISPLAY 6 TROUBLE 86 TOO MANY DEVICES ON LOOP 5 340 REMOTE DISPLAY 7 TROUBLE 87 TOO MANY DEVICES ON LOOP 6...

Page 20: ...ATION ERROR 394 ANNUN 9 NO ANSWER 141 LIB 1 NIB M S PROGRAMMING ERROR 395 ANNUN 10 NO ANSWER 142 LIB 2 NIB M S PROGRAMMING ERROR 396 ANNUN 11 NO ANSWER 143 LIB 3 NIB M S PROGRAMMING ERROR 397 ANNUN 12...

Page 21: ...CTOR PRIMARY NOT PRESENT 451 MASTER BOX NO ANSWER 198 EVENT BUFFER 80 FULL 452 DAA NO ANSWER 199 EBI STATUS 453 NO ANSWER 200 SOFTWARE MISMATCH 454 NETWORK FAILURE 201 NO POWER SUPPLY INST 455 WORKSTA...

Page 22: ...C POWER LOSS BACK UP ACTIVATED 499 STYLE 4 SHORT B L1 246 BUZZER OFF LINE 500 STYLE 4 SHORT A L2 247 PANEL DOOR OPEN 501 STYLE 4 SHORT B L2 248 OFF NETWORK 502 STYLE 4 SHORT A L3 249 INSTALL ERROR 503...

Page 23: ...2 or a corrupted message If this error occurs continuously and you need this new trouble status contact FieldServer 5 Err Unknown OFF NETWORK Node s The FieldServer received a message that a Node eit...

Reviews: