background image

LED Display

The status display LED displays the power supply and communication
status.

Terminator

Address

Settings1

Settings2

x10

x1

Display

ST(M)

PWR

PWR(V)

SF

Content

Displays the diagnostic status of the unit.

Displays the status of the power supply
voltage for control and input.

Displays the status of the power supply
voltage for outputs.

Displays system fault.

BF

Displays bus fault.

•SI unit common status

Content

The power supply for control and input is
OFF.

LED display 

OFF.

The unit is in normal operation.

Green LEDs are ON.

A component failure inside the SI unit.

Red ST(M) LED is ON.

The power supply voltage for control and
input is abnormal.

Red PWR LED is ON.

The power supply voltage for output is
abnormal.

Red PWR(V) LED is ON.

Troubleshooting

Refer to the LED Display. Refer to the SMC website
(URL http://www.smcworld.com) to obtain more detailed information
about troubleshooting.

Setting and Adjustment

ON

1

2

3

4

5

6

7

8

x10

x1

ON

1

2

3

4

0 1

2

3

4

5

6

7

8

9

0 1

2

3

4

5

6

7

8

9

Settings1

Terminator

Address

Settings2

•Address setting switch: Set the PROFIBUS DP node address.

Address

X10

0

0

:

Settings2

8

OFF

9

0

:

2

ON

Node Address

0 (Default setting)

1

:

99

100

:

125

X1

0

1

:

9

:

5

•V_SEL switch: The number of outputs (size) occupied by the SI unit is

selected.

Content

Number of valves = 32 outputs

Number of valves = 24 outputs

Number of valves = 16 outputs

Settings1

1

Number of valves = 8 outputs

SI unit output data size

4 byte (Default setting)

3 byte

2 byte

1 byte

2

OFF

OFF

ON

ON

OFF

ON

OFF

ON

•HOLD/CLEAR switch: Sets the output status when the fieldbus has a

communication error or is in idling state.

Content

Clears the output. (Default setting)

Holds the output.

Settings2

4

OFF

ON

Setting of the terminating resistor

Terminating resistor

OFF

(Default setting)

Terminating resistor

ON

Terminating resistor

OFF

•Termination switch: Selects the terminating resistor for the

PROFIBUS DP communication line.

Refer to the SMC website (URL http://www.smcworld.com) to obtain
more detailed information about setting and adjustment.

5

Diagnostic

Commissioning

•Parameter Setting
•Hardware Configuration (GSD file)
•I/O Map

Outline with Dimensions

Refer to the product catalogue or SMC website
(URL http://www.smcworld.com) to obtain more detailed information
about outline dimensions.

Refer to the SMC website (URL http://www.smcworld.com) to obtain
more detailed information about diagnostics.

Refer to the SMC website (URL http://www.smcworld.com) to obtain
more detailed information about these settings.

A unit other than the SI unit has been
detected.

Green ST(M) LED is

flashing.

Either of the following conditions:
•The valve ON/OFF counter has

exceeded the set value.

•The valve is short circuited or

disconnected.

Red ST(M) LED is flashing.

Connection error between units has
occurred.

Red/Green ST(M) LED is

flashing alternately.

The configuration data of the master and
device are not consistent.

Red SF LED is ON and

Red BF LED is flashing.

The SI unit has recognized the
communication speed, but the address
setting of the master is incorrect.

Red BF LED is flashing.

•PROFIBUS DP status

Content

The communication with the master has
been established, or the power supply for
control and inputs is OFF.

LED display 

OFF.

The communication with the master has
been established, but a diagnostic error
has occurred.

Red SF LED is ON.

Either of the following conditions:
•The cable between the master and SI

unit is not connected.

•The SI unit cannot recognize the

communication speed.

•The master or the SI unit has failed.

Red BF LED is ON.

The address of the SI unit is set to 0, or
above 126.

Red BF and SF LEDs are

both ON.

Maintenance

•Maintenance should be performed according to the Safety Instructions.
•Perform regular maintenance and inspections.

There is a risk of unexpected malfunction.

•Do not use solvents such as benzene, thinner etc. to clean each unit.

They could damage the surface of the body and erase the markings on
the body.
Use a soft cloth to remove stains.
For heavy stains, use a cloth soaked with diluted neutral detergent and
fully squeezed, then wipe up the stains again with a dry cloth.

Refer to the SMC website (URL http://www.smcworld.com) to obtain
more detailed information about maintenance.

Contacts

AUSTRIA

(43) 2262 62280 

NETHERLANDS

(31) 20 531 8888 

BELGIUM

(32) 3 355 1464 

NORWAY

(47) 67 12 90 20 

CZECH REP.

(420) 541 424 611 

POLAND

(48) 22 211 9600 

DENMARK

(45) 7025 2900 

PORTUGAL

(351) 21 471 1880

FINLAND

(358) 207 513513 

SLOVAKIA

(421) 2 444 56725 

FRANCE

(33) 1 6476 1000 

SLOVENIA

(386) 73 885 412

GERMANY

(49) 6103 4020 

SPAIN

(34) 945 184 100 

GREECE

(30) 210 271 7265 

SWEDEN

(46) 8 603 1200 

HUNGARY

(36) 23 511 390 

SWITZERLAND

(41) 52 396 3131 

IRELAND

(353) 1 403 9000 

UNITED KINGDOM

(44) 1908 563888 

ITALY

(39) 02 92711

URL http://www.smcworld.com (Global) http://www.smceu.com (Europe)

Specifications are subject to change without prior notice from the manufacturer.
© 2010 SMC Corporation All Rights Reserved.

LED Display (Continued)

EX600-TFN23

-10 to 50 

o

C

(Max. surrounding air temperature rating: 50 

o

C)

Connected load

-20 to 60 

o

C

Operating temperature

range

For use in Pollution Degree 2 Environment

(UL508)

Pollution degree

24 VDC 1.5 W (SMC)

Solenoid valve with LED and circuit protection

10 to 57 Hz: constant amplitude 0.75 mm p-p

57 to 150 Hz: constant acceleration 49 m/s

2

for 2 hours each in direction X, Y and Z

respectively (De-energized)

Vibration resistance

147 m/s

2

3 times each in directions of X, Y and

Z respectively (De-energized)

Impact resistance

Specification

24 VDC Class2, 2 A

Power
supply

24 VDC Class2, 2 A

Output

Control and input

Storage temperature

range

Refer to the product catalogue or SMC website
(URL http://www.smcworld.com) to obtain more detailed information
about product specifications.

Reviews: