6 Wiring 

6.1  Wiring connections 

 

Communication Connection 

Select the appropriate cables to mate with the connectors on the SI unit. 
The PROFINET connection port pin layout is as shown below. 

Connector 

Pin No. 

Signal name 

PORT 1 / PORT 2 

 

TX+ 

RX+ 

TX- 

RX- 

 

Warning 

  Be sure to fit a seal cap (EX9-AWTS) on any unused connectors. 

Proper  use  of  the  seal  cap  enables  the  enclosure  to  maintain  IP67 
specification. 

 

7 Settings 

7.1  Configuration 

Download the latest GSDML file and refer to the operation manual on the 
SMC  website  (URL: 

https://www.smcworld.com

)  for  further  information 

on settings. 

 

8 How to Order 

Refer  to  the  operation  manual  on  the  SMC  website  (URL: 

https://www.smcworld.com

) for How to order information.

 

 

9 Outline Dimensions (mm) 

Refer  to  the  operation  manual  on  the  SMC  website  (URL: 

https://www.smcworld.com

) for outline dimensions. 

 

10 LED Display 

       

 

Display 

Content 

ST(M) 

Displays the diagnostic status of the unit. 

PWR 

Displays the status of the power supply voltage for 
control and input. 

PWR(V) 

Displays the status of the power supply voltage for 
output. 

SF 

Displays the system status. 

BF 

Displays the communication status. 

L/A PORT1  Displays the communication status of PORT 1. 

L/A PORT2  Displays the communication status of PORT 2. 

 

 

10 LED Display (continued) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED 

LED colour 

Content 

L/A  

PORT 1 

OFF 

PORT 1: No Link, No Activity 

Green ON 

PORT 1: Link, No Activity  

Green 

flashing 

PORT 1: Link, Activity  

L/A  

PORT 2 

OFF 

PORT 2: No Link, No Activity 

Green ON 

PORT 2: Link, No Activity  

Green 

flashing 

PORT 2: Link, Activity  

 

11 Maintenance 

11.1 General Maintenance 

Caution 

  Not following proper maintenance procedures could cause the product 

to malfunction and lead to equipment damage. 

  If handled improperly, compressed air can be dangerous. 

  Maintenance  of  pneumatic  systems  should  be  performed  only  by 

qualified personnel. 

  Before performing maintenance, turn off the power supply and be sure 

to  cut  off  the  supply  pressure.  Confirm  that  the  air  is  released  to 
atmosphere. 

  After  installation  and  maintenance,  apply  operating  pressure  and 

power  to  the  equipment  and  perform  appropriate  functional  and 
leakage tests to make sure the equipment is installed correctly. 

  If any electrical connections are disturbed during maintenance, ensure 

they  are  reconnected correctly  and  safety checks  are carried  out  as 
required  to  ensure  continued  compliance  with  applicable  national 
regulations. 

  Do not make any modification to the product. 

  Do  not  disassemble  the  product,  unless  required  by  installation  or 

maintenance instructions 

  Stop operation if the product does not function correctly. 

 

12 Limitations of Use 

12.1 Limited warranty and Disclaimer/Compliance Requirements 

Refer to Handling Precautions for SMC Products. 
 

13 Product disposal 

This product should not be disposed of as municipal waste. Check your 
local  regulations  and  guidelines  to  dispose  of  this  product  correctly,  in 
order to reduce the impact on human health and the environment. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

14 Contacts 

Refer  to 

www.smcworld.com

  or 

www.smc.eu

 for your  local  distributor  / 

importer. 
 

 

URL :    https://www.smcworld.com (Global)      https://www.smc.eu (Europe) 
SMC Corporation, Akihabara  UDX15F, 

4-14-1

, Sotokanda, Chiyoda-ku, Tokyo 

101 

0021

 

Specifications are subject to change without prior notice from the manufacturer.  
© 

2021

 SMC Corporation All Rights Reserved. 

Template DKP50047-F-085L

 

L/A PORT1 

LED  

LED colour 

Operation 

ST(M) 

OFF 

The power supply for control and input is OFF. 

Green ON  Normal operation. 

Green 

flashing 

Diagnostic error in I/O unit detected. 

Red 

flashing 

Either of the following diagnostics errors 
detected (with diagnostics enabled): 
•Valve ON/OFF counter exceeded the set 
value. 
•Valve is short circuited or disconnected. 

Red/Green 

flashing 

Communication error detected between SI unit 
and I/O unit. 

Red ON 

SI unit has failed. 

PWR 

Green ON 

The power supply voltage for control and input 
is normal. 

Red ON 

The power supply voltage for control and input 
is below 19 VDC (with diagnostics enabled). 

PWR(V) 

OFF 

The power supply voltage for output is OFF or 
below 19 VDC (with diagnostics disabled). 

Green ON  The power supply voltage for output is normal. 

Red ON 

The power supply voltage for output is OFF or 

Below 19 VDC

 

(with diagnostics enabled)

.

 

SF 

OFF 

Normal operation. 

Red ON 

Diagnostics error detected. 

Green 

flashing 

Node flashing test 

BF 

OFF 

PROFINET communication established. 

Red 

flashing 

The PLC configuration data and the EX600 
configuration are not consistent. 

Red ON 

Either of the following conditions: 

  Device name setting to PLC and SI unit is 

not consistent. 

  Communication cable not connected. 

  PLC or SI unit is faulty. 

L/A PORT2 

ST(M)  PWR  PWR(V)  SF  BF 

Reviews: