EX600-TFL26GB

8. Wiring (continued)

Wiring connection with handheld terminal

Refer to “Handheld Terminal Operation Manual” for the connection with
the handheld terminal.

1

2

3

4

5

Note

Be sure to place a seal cap on any unused connectors. Placing the
seal cap appropriately enables the unit to achieve IP67 protection.

BUS IN

Status indication LED (see figure below) displays the  power
supply status and communication status. These can be checked
according to the following:

<Display status>

Indicator

symbol

Status

Indicator

symbol

Status

OFF

Flashing Red

Red Light ON

Flashing Red and

Green alternately

Green Light ON

Flashing Green

9. Trouble Shooting

<Common for SI Units>

Indicator

Status

Power for control/input is OFF.

Unit is operating normally.

Abnormal power voltage for control/input. Check the power
supply and adjust or replace it.

Abnormal power voltage for output. Check the power
supply and adjust or replace it.

Component failure inside SI unit. 
When ST(M) indicator is red, stop using the product and
contact SMC.

•Valve is in short circuit or open circuit. 
•Valve ON/OFF counter has exceeded the set value.

Communication error between units, or configuration memory
error. 
Check the connection between units, or the unit configuration.

Error diagnostics  detected the error of a unit other than the
SI unit.

<SI Unit - DeviceNet

TM

>

Indicator

Status

Power is OFF.

Communicating normally.

Checking node address duplication.

Critical communication error.

Check the node Address or Data Rate etc.

Connection cannot be established.

Non-critical communication error.
Check the Data Rate etc.

Performing self diagnostics at start up.

Component failure inside SI unit. Stop using the product
and contact SMC.

Note

Be sure to connect a termination resistor at both ends of the
DeviceNet

TM

trunk line.

Turn-lock mechanism 

of the connector

Signal name

Pin No.

Wire colour

DRAIN

1

Drain

V+

2

Red

V-

3

Black

CAN H

4

White

CAN L

5

Blue

Turn the connector clockwise. It stops when turned 1/4 turn.Turn it

further. When the connector is turned 1/2 turn from the original 

position, the projected portion is set at the diagonal position to the

mark and the turn is completed. Check that the connector is
securely locked.
If the connector is turned excessively, it will become difficult to
remove.

<Mounting the marker>

Mount the marker (EX600-ZT1) into the marker groove as required.

<Connection>

10. Contact

AUSTRIA

(43) 2262 62280  NETHERLANDS

(31) 20 531 8888 

BELGIUM

(32) 3 355 1464  NORWAY

(47) 67 12 90 20 

CZECH REP.

(420) 541 424 611  POLAND

(48) 22 211 9600 

DENMARK

(45) 7025 2900  PORTUGAL

(351) 21 471 1880

FINLAND

(358) 207 513513  SLOVAKIA

(421) 2 444 56725 

FRANCE

(33) 1 6476 1000  SLOVENIA

(386) 73 885 412

GERMANY

(49) 6103 4020  SPAIN

(34) 945 184 100 

GREECE

(30) 210 271 7265  SWEDEN

(46) 8 603 1200 

HUNGARY

(36) 23 511 390  SWITZERLAND

(41) 52 396 3131 

IRELAND

(353) 1 403 9000  UNITED KINGDOM

(44) 1908 563888 

ITALY

(39) 02 92711

URL http://www.smcworld.com (Global)  http://www.smceu.com (Europe)

Specifications are subject to change without prior notice from the manufacturer. 
© 2009 SMC Corporation All Rights Reserved.