7

6

Product Summary

System structure

(                     )

(                   )

Power supply

for output
Power supply

for input and

controling GW 

24 VDC
24 VDC

GW unit

Input unit

1 connector

2 inputs type

Input unit 

1 connector

1 input type

connecting to

4 sets maximum

Branch cable

(EX510-FC       )

Valve manifold 

with SI unit 

connecting to

4 sets maximum

Connecting to bus

at upper level

(CC-Link)

(                           )

(                           )

The system which realizes wiring saving and distributed
installation by connecting to CC-Link. The signal to CC-Link is
transmitted by GW unit, and the signal to input/output device
which is installed discretely is collected by GW unit.

Name of Parts/ Accessories

Communication

connector for 

CC-Link

(1 piece)

Power supply

connector

(2 pieces)

Accessory

10

11

8

4

7

5

1

6

9

2 3

No.

Parts

Purpose

1

Communication
socket (BUS)

Connect to CC-Link line with an accessory
connector for CC-Link (

). 

2

Power supply
socket (PWR(V))

Supplying power for output instruments such as a
solenoid valve with an accessory connector (

). 

3

Power supply
socket (PWR)

Supplying power for controlling GW and for
input instruments such as a sensor with an
accessory connector (

). 

4

GW unit side
branch connector
(for input)

Connecting an input unit etc. by using branch
cables (EX510-FC

).

5

GW unit side
branch connector
(for output)

Connecting SI unit (manifold valve) etc. by
using branch cables (EX510-FC

).

6

FG terminal

Used for grounding

7

Mounting hole

Used when a unit is mounted with two M4 screws.

8

DIN rail mounting
slot

Used when a unit is mounted to DIN rail.

9

Display/ switch
setting part

Sets up the switch on such as LED display and
address, I/O points.

: For wiring method, refer to "Wring" in the "Operation Manual".

Summary of Contents for EX510 Series

Page 1: ...ns are subject to change without prior notice and any obligation on the part of the manufacturer 2003 2017 SMC Corporation All Rights Reserved EX OMH0014 C Akihabara UDX 15F 4 14 1 Sotokanda Chiyoda k...

Page 2: ...l has been written for those who have knowledge of machinery and apparatuses that use fieldbus system and have full knowledge of assembly operation and maintenance of such equipment Please read this o...

Page 3: ...r damage to the product can result Verify the specifications before use Do not disassemble modify including change of printed circuit board or repair An injury or failure can result IMPORTANT MESSAGES...

Page 4: ...asures when installing at the following place 1 A place where noise due to static electricity is generated 2 A place where electric field strength is high 3 A place where there is radioactive irradiat...

Page 5: ...7 5 1 6 9 2 3 No Parts Purpose 1 Communication socket BUS Connect to CC Link line with an accessory connector for CC Link 2 Power supply socket PWR V Supplying power for output instruments such as a s...

Page 6: ...M A COM B COM C COM D OUTPUT INPUT 60 80 16 PWR V PWR BUS Settings Perspective drawing tolerance 0 2 16 PWR V PWR BUS OUTPUT INPUT 70 5 54 5 2 M4 Tightening torque 0 8 Nm DIN rail PWR V PWR BUS Mounte...

Page 7: ...x 20 V Rated current Input output point Power supply for input and controlling GW Max 4 1 A Inside GW unit 0 1 A input unit 4 A Current for output Max 6 A Input point Max 64 Output point Max 64 Change...

Page 8: ...rs for each Pressure welding for branch connector The method of pressure welding for branch connector is explained 1 Components 2 Working procedure Set a branch cable to the cover 1 Set the brown wire...

Page 9: ...not pull the branch connector and branch cable after wiring There is a risk of damage 3 Do not open and close the branch connector hook repeatedly There is a risk of damage 4 Cut the branch cable and...

Page 10: ...to Drawing 3 DA DB DG SLD FG Yellow White Shield Blue Terminating resistor Drawing 3 3 The terminal resistor to connecct differs depending on a cable to use at CC Link system Refer to table below Cabl...

Page 11: ...no data to receive Goes off COM B COM B is receiving data Lights up COM B is having no data to receive Goes off COM C COM C is receiving data Lights up COM C is having no data to receive Goes off COM...

Page 12: ...o 156 kbps Transmission speed 156 kbps 625 kbps 2 5 Mbps 5 Mbps No 8 OFF OFF OFF OFF No 9 OFF OFF ON ON No 10 OFF ON OFF ON 10 Mbps ON OFF OFF 40 No 1 1 Station number 2 3 4 10 11 62 63 Station number...

Page 13: ...the connection of UNLIT COM port branch to input unit 4 COM A D is not LIT Signals cannot be received even with a sensor Solenoid valve is not working Valve is not working as program directs No Item...

Page 14: ...the power for output 24 VDC is supplied Check the power supply voltage for output is getting as low as under 20 V Check the signal line from PLC is correctly connected Check the wiring and pin number...

Reviews: