-6- 

 

No.EX

※※

-OMV0023 

 

 

Product handling 

Installation 
•Do not drop, hit or apply excessive shock to the fieldbus system. 

Otherwise damage to the product can result, causing malfunction. 

•Tighten to the specified tightening torque.

 

If the tightening torque is exceeded the mounting screws may be broken. 
IP67 protection cannot be guaranteed if the screws are not tightened to the specified torque. 

•Never mount a product in a location that will be used as a foothold.

 

The product may be damaged if excessive force is applied by stepping or climbing onto it. 

Wiring 
•Avoid repeatedly bending or stretching the cables, or placing heavy load on them.

 

Repetitive bending stress or tensile stress can cause breakage of the cable. 

•Wire correctly. 

Incorrect wiring can break the product. 

•Do not perform wiring while the power is on. 

Otherwise damage to the fieldbus system and/or I/O device can result, causing malfunction. 

•Do not route wires and cables together with power or high voltage cables. 

Otherwise the fieldbus system and/or I/O device can malfunction due to interference of noise and surge voltage 
from power and high voltage cables to the signal line. 
Route the wires (piping) of the fieldbus system and/or I/O device separately from power or high voltage cables

Confirm proper insulation of wiring. 

Poor insulation (interference from another circuit, poor insulation between terminals, etc.) can lead to excess 
voltage or current being applied to the product, causing damage. 

•Take appropriate measures against noise, such as using a noise filter, when the fieldbus system is 

incorporated into equipment. 

Otherwise noise can cause malfunction. 

•Separate the power line for output devices from the power line for control. 

Otherwise noise or induced surge voltage can cause malfunction. 

Environment 
•Select the proper type of protection according to the environment of operation. 

IP67 protection is achieved when the following conditions are met. 

(1) The units are connected properly with fieldbus cable with M12 connector and power cable with M12 (M8) 

connector. 

(2) Suitable mounting of each unit and manifold valve. 

If using in an environment that is exposed to water splashes, please take measures such as using a cover. 

•Do not use in a place where the product could be splashed by oil or chemicals.

 

If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, even 
for a short time, it may be adversely affected (damage, malfunction etc.). 

•Do not use the product in an environment where corrosive gases or fluids could be splashed. 

Otherwise damage to the product and malfunction can result. 

•Do not use in an area where surges are generated.

 

If there is equipment which generates a large amount of surge (solenoid type lifter, high frequency induction furnace, 
motor, etc.) close to the fieldbus system, this may cause deterioration or breakage of the internal circuit of the 
fieldbus system. Avoid sources of surge generation and crossed lines. 

•When a surge-generating load such as a relay or solenoid is driven directly, use an fieldbus system with 

a built-in surge absorbing element. 

Direct drive of a load generating surge voltage can damage the fieldbus system. 

•The product is CE marked, but not immune to lightning strikes. Take measures against lightning strikes 

in the system.

 

•Prevent foreign matter such as remnant of wires from entering the fieldbus system to avoid failure and 

malfunction. 

Summary of Contents for EX260-SPL1

Page 1: ...No EX OMV0023 PRODUCT NAME SI unit for Ethernet POWERLINK MODEL Series Product Number EX260 Series...

Page 2: ...Indication and How to Order 8 Summary of Product elements 9 Installation and Wiring 10 Installation 10 Wiring 11 LED Indication and Settings 15 Configuration 17 Troubleshooting and Maintenance 21 Spe...

Page 3: ...quipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly Th...

Page 4: ...responsibility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the...

Page 5: ...ct outside of the specifications Do not use for flammable or harmful fluids Fire malfunction or damage to the product can result Verify the specifications before use Do not operate in an atmosphere co...

Page 6: ...ion installation wiring environment adjustment operation maintenance etc described below must also be followed Product specifications When conformity to UL is required the SI unit should be used with...

Page 7: ...cause malfunction Separate the power line for output devices from the power line for control Otherwise noise or induced surge voltage can cause malfunction Environment Select the proper type of protec...

Page 8: ...efer to the PLC manufacturer s manual etc for details of programming and addresses For the PLC protocol and programming refer to the relevant manufacturer s documentation The surface on the product ma...

Page 9: ...23 Model Indication and How to Order EX260 SPL 1 Connector type output specification 1 M12 connector 32 outputs PNP negative common source 3 M12 connector 16 outputs PNP negative common source Fieldbu...

Page 10: ...SI unit 1 M12 5 pin plug A coded 4 Ground terminal Functional earth M3 screw 5 Output connector Output signal interface for valve manifold 6 LED display LED display to indicate the status of the SI u...

Page 11: ...7 136 7 152 7 168 7 184 7 200 7 216 7 L2 80 96 112 128 144 160 176 L 9 10 11 12 13 14 15 16 L1 232 7 248 7 264 7 280 7 296 7 312 7 328 7 344 7 L2 192 208 224 240 256 272 288 304 mm The above table sh...

Page 12: ...Data 4 RD Receive Data Connect the BUS IN connector to the upstream device PLC etc and connect the BUS OUT connector to the downstream device The M12 connector cable has two types SPEEDCON compatible...

Page 13: ...SI unit operation 4 SI0 V 0 V for SI unit operation 5 Unused The M12 connector cable has two types SPEEDCON compatible and non compatible If both plug and socket sides have connectors for SPEEDCON the...

Page 14: ...id valve and power supply line for SI unit operation are isolated Be sure to supply power respectively Either single source power or two different power supplies can be used Pay attention not to excee...

Page 15: ...14 No EX OMV0023 Ground terminal Connect the ground terminal to ground Resistance to ground should be 100 ohms or less...

Page 16: ...ID set outside range ST OFF SI unit operating voltage is not supplied Green ON Operating normally Red ON SI unit has failed L A1 OFF BUS IN side No Link No Activity Green ON BUS IN side Link No Activ...

Page 17: ...16 No EX OMV0023 Switch setting The switches should only be set with the power supply turned off Open the cover and set the rotary switches and DIP switch with a small flat blade screwdriver...

Page 18: ...SMC website URL http www smcworld com XDD file Model number XDD file 1 EX260 SPL1 FFFF0007_EX260 SPL1 xdd 2 EX260 SPL3 FFFF0007_EX260 SPL3 xdd The network configuration procedure using the B R s Autom...

Page 19: ...18 No EX OMV0023 2 Select Add Hardware Module by right clicking PLK from the Project Explorer 3 Double click or drag and drop the SI unit model number from the Hardware Catalog and place it below PLK...

Page 20: ...19 No EX OMV0023 4 Select Change Node Number by right clicking SI unit and input the Node ID number...

Page 21: ...as shown in the figure a If a single solenoid valve is mounted on the standard wiring manifold the output number for the B side valve is skipped Custom wiring for mixed mounting single solenoid valve...

Page 22: ...is OFF SI unit L A LED is OFF Refer to fault No 2 SI unit ST LED is red ON Refer to fault No 1 Refer to fault No 3 Refer to fault No 4 Yes No All valves and valve LEDs are not operating Group of valv...

Page 23: ...power cable Replace the cable if it is broken Correct the power cable wiring layout Load voltage for the valve is not supplied Check the condition of the supply voltage for the valve Supply 24 VDC 10...

Page 24: ...rror handling Recommended action SI unit S E LED is green flashing POWERLINK communication is not established Check that the configuration information registered in the POWERLINK master matches the pr...

Page 25: ...Mismatch polarity between solenoid valve and SI unit output Check if the solenoid valve common specification matches the output polarity of the SI unit Match polarity between solenoid valve and SI uni...

Page 26: ...htening torque 0 6 Nm Precautions for maintenance 1 Be sure to switch off the power 2 Check there is no foreign matter inside the SI unit 3 Check there is no damage and no foreign matter on the gasket...

Page 27: ...lenoid valve station specification Solenoid valve connecting specification Output type PNP negative common source Connected load Solenoid valve with surge voltage suppressor of 24 VDC and 1 5 W or les...

Page 28: ...cifications Item Status State SOLV State of power supply for solenoid valve 0 Normal 1 Abnormal 19 V or less Output area mapping For EX260 SPL1 Offset Word Output data MSB LSB MSB LSB 15 8 7 0 0 15 14...

Page 29: ...y connection and the SI unit is installed directly to a valve manifold the cable connector s outer diameter should be 16 mm or less If it is a larger diameter the connector will interfere with the mou...

Page 30: ...mm 4 Blue RD Nominal cross section AWG22 Wire diameter Including insulator 1 5 mm Min bending radius Fixed 19 5 mm 2 Fieldwireable connector Part number PCA 1446553 Applicable cable Item Specificatio...

Page 31: ...l cross section AWG26 Min bending radius Fixed 26 mm 4 Seal cap Part number EX9 AWTS This cap is used to protect the M12 connector opening when the connector is not used When the BUS OUT connector is...

Page 32: ...ength L 1 1000 mm 5 5000 mm EX500 AP0 0 S EX500 AP0 0 A Item Specifications Pin No Cable colour Signal Cable O D 6 mm 1 Brown 24 VDC For solenoid valve Nominal cross section AWG22 2 White 0 V For sole...

Page 33: ...Specifications Pin No Cable colour Signal Connector M12 Straight SPEEDCON 1 Brown 24 VDC For solenoid valve 2 White 0 V For solenoid valve Cable O D 5 mm 3 Blue 24 VDC For control Nominal cross secti...

Page 34: ...hiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manu...

Reviews: