-10-
No.EX
※※
-OMW0016
■
Summary of product function
I/O function
This device can control 32 outputs for solenoid valve control and check device status using cyclic data
communication via IO-Link system.
Fault action
Output action at a communication fault can be set by parameter, either Clear Output, Force Output or Hold
Last State.
Output switching counter
This device can count the number of output switching cycles on each single output and the count value can
be automatically stored in the device every hour or automatically
in the SI unit when the IO-Link power is
turned off.
: Depending on the situation of the voltage change at power OFF, it may not be possible to save.
Device condition (diagnosis) monitoring
This device can provide information about the device condition (diagnosis) over the IO-Link.
•This device can detect various error status, such as internal hardware fault and output open/short circuit.
•This device can detect various warning status, such as solenoid power over-run/under-run and device
temperature over-run.
•Also, the device can notify when the output switching count reaches the upper limit value set by the user
arbitrarily.
Data Storage function
Data Storage is a function which enables a consistent and up-to-date set of device parameters to be stored
in the Master. The main purpose of the IO-Link Data Storage mechanism is to ease the replacement of
defect devices without using configuration, parameterization, or other tools.
When the user has assigned parameter values with the help of engineering tools, they are downloaded into
the device and become active parameters. Upon a system command, these parameters are uploaded
(copied) into the Data Storage within the Master.
The stored (saved) set of back-up parameters overwrite the active parameters (e.g. factory settings) within
the compatible replacement device.
Data Storage provides three different "Backup Levels" of parameters to be defined on the Master port using
engineering tools, Commissioning ("Disable"), Production ("Backup/Restore") and Production ("Restore").
"Backup" means that upload is enabled and "Restore" means that download is enabled.