Instruction Manual 

Fieldbus device - SI unit for PROFINET 

EX260-MPN1

 

 

The intended use of this SI unit is for the control of pneumatic valves and 
I/O while connected to the PROFINET network.

 

1 Safety Instructions 

These safety instructions are intended to prevent hazardous situations 
and/or equipment damage. These instructions indicate the level of 
potential hazard with the labels of “Caution,” “Warning” or “Danger.” 
They are all important notes for safety and must be followed in addition 
to International Standards (ISO/IEC)

 *1)

, and other safety regulations. 

*1)

 ISO 4414: Pneumatic fluid power - General rules relating to systems. 

ISO 4413: Hydraulic fluid power - General rules relating to systems. 
IEC 60204-1: Safety of machinery - Electrical equipment of machines. 
(Part 1: General requirements) 
ISO 10218-1: Manipulating industrial robots -Safety. etc. 

  Refer to product catalogue, Operation Manual and Handling 

Precautions for SMC Products for additional information. 

  Keep this manual in a safe place for future reference. 

 

Caution 

Caution indicates a hazard with a low level of risk which, if 

not avoided, could result in minor or moderate injury. 

 

Warning 

Warning indicates a hazard with a medium level of risk 

which, if not avoided, could result in death or serious injury. 

 

Danger 

Danger indicates a hazard with a high level of risk which, if 

not avoided, will result in death or serious injury. 

Warning 

 

Always ensure compliance with relevant safety laws and 
standards. 

  All work must be carried out in a safe manner by a qualified person in 

compliance with applicable national regulations. 

 

Caution 

 

Provide grounding to assure the safety and noise resistance of 
the Fieldbus system. 

Individual grounding should be provided close to the product using a 
short cable. 

  Refer to the operation manual on the SMC website (URL: 

https://www.smcworld.com

) for further Safety Instructions.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

2 Specifications 

2.1  General specifications 

Item 

Specifications 

Ambient temperature 

-10 to +50 

o

Ambient humidity 

35 to 85% RH (no condensate) 

Ambient storage temperature 

-20 to +60 

o

Withstand voltage 

500 VAC applied for 1 minute 

Insulation resistance 

500 VDC, 10 M

Ω

 or more 

Operating atmosphere 

No corrosive gas 

Enclosure protection class 

IP67 (IEC 60529) 

Weight 

200 g or less 

Dimensions (W x L x H) mm 

28.2 x 102.4 x 76.5 

 

2.2  Electrical specifications 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

2.3  Communication specifications 

Item 

Specifications 

Protocol 

PROFINET IO 

Conformance class C 

Yes (only for IRT switch function). 

Transmission medium 

Standard Ethernet cable (CAT5) 

(100BASE-TX) 

Transmission speed 

100 Mbps 

FSU (Fast Start Up) 

Yes 

MRP (Media Redundancy 
Protocol) 

Yes 

MRPD (Media Redundancy 
for Planned Duplication) 

Yes 

Shared device 

Yes 

PROFIenergy 

Yes 

System redundancy S2 

Yes 

Security level 1 
Net Load Class III 

Yes 

Vendor ID 

0083h 

Device ID 

0016h 

GSD configuration file 

GSDML-V2.41-SMC-EX260-MPN1-

∗∗∗∗∗∗∗∗

.xml 

 

 
 
 
 
 
 

3 Name and function of parts 

 

 

 

No 

Part 

Description 

Fieldbus connector 
(BUS OUT) 

PROFINET connection PORT2 
(M12 4-pin socket, D-coded). 

Fieldbus connector 
(BUS IN) 

PROFINET connection PORT1 
(M12 4-pin socket, D-coded). 

Power supply 
connector 

Power supply for valves and logic of the SI 
unit (M12 4-pin plug, A-coded). 

4  Ground terminal 

Functional Earth terminal (M3). 

5  Output connector 

Output signal interface for valve manifold. 

6  LED display 

LED display to indicate the SI unit status. 

7  Mounting hole 

Mounting hole for connection to the valve 
manifold. 

8  Product label 

Label to indicate the SI unit MAC address, 
Serial number, etc.. 

 
Accessories 

Item 

Description 

Hexagon socket head 
cap screw 

M3 x 30 mm, 2 pcs. For valve manifold 
connection. 

Seal cap 

Seal cap (1 pc.) for M12 unused connector. 

4 Installation 

4.1  Installation 

Warning 

  Do not install the product unless the safety instructions have been read 

and understood. 

  Assemble the SI unit to the valve manifold using the 2 screws supplied 

(Hexagonal socket wrench size 2.5 mm). 

  Tighten the screws while holding the SI unit and the valve manifold so 

that there is no gap between them.  

  Tighten the screws with the tightening torque specified: 0.6 N•m. 

For a protection rating of IP67 to be ensured, apply the recommended 
tightening torque. 

 

4.2  Assembly Precautions 

  Be sure to switch OFF the power. 

  Check there is no foreign matter inside the SI unit. 

  Check there is no damage and no foreign matter stuck to the gasket. 

  Be sure to tighten the screws with the specified torque. 

  If the SI unit is not assembled properly, the internal PCBs may be 

damaged or liquid and/or dust may enter into the unit. 

 

4 Installation (continued) 

4.3  Environment 

Warning 

  Do not use in an environment where corrosive gases, chemicals, salt 

water or steam are present. 

  Do not install in a location subject to vibration or impact in excess of 

the product specifications. 

  Do not use in a place where the product could be splashed by oil or 

chemicals. 

 

Do not use in an area where surges are generated.

 

 

Do not operate close to a heat source, or in a location exposed to 
radiant heat.

 

 

Do not use the product in an environment that is exposed to 
temperature cycles.

 

 

Do not expose the product to direct sunlight or UV light.

 

 

5 Wiring 

  Wiring must be carried out with the power supply turned OFF. 

5.1  Communication Connectors (BUS IN and BUS OUT) 

The SI unit has 2 PROFINET communication connectors. 
Select the appropriate cable  (SMC Part No. EX9-AC###EN-####)  to 
mate with the PROFINET connectors mounted on the SI unit. 
 

 

Fieldbus interface connector 

 

BUS IN / BUS OUT: M12 4-pin socket, D-coded 

No. 

BUS IN - Port1 

(Type MDI) 

BUS OUT - Port2 

(Type MDI-X) 

TD+ Transmit Data + 

RD+ Receive Data + 

RD+ Receive Data + 

TD+ Transmit Data + 

TD- Transmit Data - 

RD- Receive Data - 

RD- Receive Data - 

TD- Transmit Data - 

 

5.2  Power supply connector layout 

  Select the appropriate cable (SMC Part No. EX500-AP0#0-#) to mate 

with the power supply connector mounted on the SI unit. 

 

PWR: M12 4-pin plug, A-coded

 

No. 

Designation 

Description 

24 V (PWR(V)) 

+24 V for solenoid valve 

0 V (PWR(V)) 

0 V for solenoid valve 

24 V (PWR) 

+24 V for SI unit operation 

0 V (PWR) 

0 V for SI unit operation 

 

  The power supply for the solenoid valve and SI unit operation are 

isolated. Be sure to supply power respectively. 
Either single source power or two different power supplies can be used. 

  The 24 VDC supply for logic (PWR) and the 24 VDC supply for the 

valves (PWR(V)) should be protected with an external fuse. 
 

The M12 connector cable for fieldbus and power supply connections 
has two types, Standard M12 and SPEEDCON compatible. If both 
plug and socket have SPEEDCON  connectors, the cable can be 
inserted and connected by turning it a 1/2 of a rotation, leading to a 
reduction in man hours. A standard connector can be connected to 
a SPEEDCON connector. 

 

Warning 

  Be sure to fit a seal cap (EX9-AWTS) on any unused connectors. 

Proper use of the seal cap enables the enclosure to maintain IP67 
specification. 

 

5.3  Ground Terminal 

 

The SI Unit must be connected to FE (Functional Earth) to divert 
electromagnetic interference. 

 

  Connect a grounding cable from the FE terminal screw on the SI Unit 

to the nearest functional earth point. The

 

grounding cable should be 

as thick and short as possible (tightening torque = 0.6 N•m). 

  Resistance to ground should be 100 ohms or less. 

ORIGINAL INSTRUCTIONS 

 

 

 

Item 

Specifications 

PWR 

For logic 

Operating voltage 

24 VDC +20% / -15% 

Under voltage detection 

Less than 18 VDC approx. 

Internal current 
consumption at 24 VDC 

0.2 A or less 

Supply interruption for 
no loss of function 

1 ms max. (depending on 

number of valve stations) 

PWR(V) 

For valves 

Operating voltage 

24 VDC +20% / -15% 

Voltage drop to valve 
supply 

1.2 V max. at 24 VDC 

Protection against polarity reversal 

Yes (PWR and PWR(V)) 

Galvanic isolation 

Yes (between PWR and 

PWR(V)) 

Solenoid 
valve 
specification 

Applicable valve series 

JSY 64 stations compatible 

manifold series 

Maximum number of 
valve outputs 

128 

Over current detection / 
protection 

Yes 

(on the valve manifold) 

 