134
Parameter: <slotno>
is the number of the slot (The range value: 1 to 4, M1, M2, and 5
to 8)
Default:
if slotno does not specify any, then the default displays all of the module
information.
Command mode:
Admin Mode
Example:
Switch# show slot 1
--------slot : 1--------
Inserted: YES
slot type is: EM4704BD-M12GX-SFP
work mode: active master
work state: RUNNING
software version is: RW-1.3.2
hardware version is: 1.1
bootrom version is: 1.3.1
serialNo is: N043900039
manufactureDate is: 2004/09/10
temperature is: 33.4375
3.3.1.2 show fan
Command: show fan
Function:
to display whether the fan exists or not
Parameter:
None
Default:
not display
Command mode:
Admin Mode
Instructions:
“Inserted” means whether the fan exists or not. One fan tray contains four
fans.
Example:
Switch# show fan
----------fan information----------
fan board Inserted: OK
3.3.1.3 show power
Command: show power
Function:
to display whether the power exists or not
Parameter:
None