Other Functions

Speed

Time

READY output

External input stop command

Longer than 50ms

External input stop function

External input stop is the function to stop the slider by decelerating with the acceleration
speed set by the acceleration speed set SW by means of stop command input from external
device.

External input stop command more than 50ms.
Signal does not necessary have to be pulse.
Continuous input is acceptable.

Operation Characteristics

Longer than 1s

Install power supply

READY output

Install power supply

Alarm output

READY output

2s or less

2s or less

When power supply is applied, the controller is initialized and then READY output is performed.
If first transit of used power supply is 1s or more, the alarm output is performed in prior 
to initialization and READY output.
If emergency stop input is released, READY output is not sent and alarm output is generated
instead.

A

 

READY output

The input transmit drive command 1

The input transmit drive command 2

The input transmit drive command 3

The output for completion of positioning 1

The output for completion of positioning 2

The output for completion of positioning 3

State of operation

Operation

Stop

Do not turn off input of drive command until READY output is confirmed.
The signal for completion of positioning is output when the actuator reaches the position 0.5mm
before target position (indicated as A).

Application of power supply

Movement to end

Ex.)Movement from motor side to end side

Ex.)Movement from motor side to intermediate 1

READY output

The input transmit drive command 1

The input transmit drive command 2

The input transmit drive command 3

The output for completion of positioning 1

The output for completion of positioning 2

The output for completion of positioning 3

State of operation

Operation

Stop

5ms or less

A

A

 

READY output

The input transmit drive command 1

The input transmit drive command 2

The input transmit drive command 3

The output for completion of positioning 1

The output for completion of positioning 2

The output for completion of positioning 3

State of operation

Operation

Stop

Ex.)Movement from motor side to intermediate 2

When operation command input 1 and 3 are
input within 5ms, the operation of intermedi-
ate stop 2 starts.
When it is longer than 5ms, the slider moves
the motor side or intermediate stop 1.
when the actuator reaches the position
0.5mm before target position (indicated as A).

Do not turn off input of drive command until
READY output is confirmed.
The signal for completion of positioning is out-
put when the actuator reaches the position
0.5mm before target position (indicated as A).

Intermediate operation

Summary of Contents for E-MY2B Series

Page 1: ...e Rodless Actuator E MY2B Series Operation Manual URL http www smcworld com...

Page 2: ...FINLAND 358 9 859 580 PORTUGAL 351 2 610 89 22 FRANCE 33 1 64 76 1000 SPAIN 34 945 18 4100 GERMANY 49 6103 4020 SWEDEN 46 8 603 0700 GREECE 30 1 342 6076 SWITZERLAND 41 52 396 3131 HUNGARY 36 1 371 13...

Page 3: ...injury Do not disassemble remodel including change of printed circuit board or repair An injury or failure can result Do not operate beyond specification range Fire malfunction or switch damage can re...

Page 4: ...t use in the environment subject to temperature cycle Do not use where close to surge generating source Do not short the load Short of the load of the controller is indicated as error but it may cause...

Page 5: ...controller Encoder cable of the actuator Motor cable of the actuator Controller separated type Installation Read Precautions for Handling of safety Instruction and How to install of this chapter with...

Page 6: ...rail While pushing it fix it by the clamp of screw in fig 4 Inadequate pushing may cause falling of parts Direct mounting Use M4 mounting screw shown in fig 1 or M5 tap hole to mount the controller Ho...

Page 7: ...t light goes out blink lighting No Content Function Stroke learning switch The switch to move the actuator to intermediate position and set the intermediate position The switch to move the work to mot...

Page 8: ...bnormal stroke Abnormality of motor Abnormality of controller Abnormal detection items Current consumption Current consumption DC24V 10 30mA output load capacity at DC24V Power supply voltage Symbol C...

Page 9: ...g OUT2 OUT3 Symbol Command IN1 Command to operate motor side Command to operate end side Command to operate intermediate stop IN2 Symbol Connection of the motor and the controller When controller sepa...

Page 10: ...ps MOTOR and END are blinking Since the actuator starts moving automatically to learn the adjusted stroke do not put any objection such as tool and work around the actuator 3 3 After stroke learning i...

Page 11: ...stment of switch and the speed of actuator is set Rotary switch to set speed of movement to the direction of the motor side Rotary switch to set speed of movement to the direction of the end side 6 2...

Page 12: ...ce Noise resistance Between external terminal and case 50 M 500 VDC 1000 Vp p Pulse width 1 s Rise time 1 ns Acquired certified standard CE marking Item Specification Transfer acceleration set range M...

Page 13: ...MIDDLE indicator lamp Green MOTOR indicator lamp Green END indicator lamp Green PWR indicator lamp Green ALM indicator lamp Red Power is turn on Symbol When positioning completed External input stop c...

Page 14: ...y of motor Abnormality of controller Abnormal detection items Current consumption Current consumption DC24V 10 30mA output load capacity at DC24V Power supply voltage Symbol Cable color Signal name Co...

Page 15: ...IN1 Command to operate motor side Command to operate end side Command to operate intermediate stop 1 Command to operate intermediate stop 2 Command to operate intermediate stop 3 External input stop c...

Page 16: ...tor lamp of MIDDLE MOTOR and END blink for max 3s When intermediate position is not set position 1 to 3 are all set at the center of the stroke Press again within 3s after pressing Press within 3s aft...

Page 17: ...r side is moved the intermediate position is changed On the other hand change of the position of the stroke adjusting unit at stroke does not make sense If the stroke is set shorter than the distance...

Page 18: ...not turn off input of drive command until READY output is confirmed The signal for completion of positioning is output when the actuator reaches the position 0 5mm before target position indicated as...

Page 19: ...00 to 1000 mm s Acceleration and deceleration method Trapezoidal drive Moving direction Horizontal direction Positioning points Both ends mechanical stoppers 3 intermediate position Intermediate stopp...

Page 20: ...m alarm reset Abnormal drive Max output is continued for prolonged period Check the weight of work and foreign material attached to actuating part and then perform alarm reset Tuming off Ligting blink...

Page 21: ...om alarm condition Alarm output Longer than 50ms Emergency stop input READY output contact is opened External alarm reset Even if alarm occurs it recovers from alarm condition by inputting emergency s...

Reviews: