background image

-6- 

 

No.D-

S-OMB0023-B

 

 

 

Wiring 

•Do not pull the lead wires. 

Especially never lift actuator equipped with Auto switch by holding the lead wires. 
It can result in damage to inside of Auto switch causing malfunction. 

•Do not bend or apply tensile stress to lead wires repeatedly. 

Wiring with repetitive bending stress or tensile stress can cause peel of a sheath. 
If the lead wire can move, fix it near the body of the Auto switch. 
A bend radius of about 40 to 80 mm is recommended. Contact us for the details. 

•Connect wires and cables correctly. 

Miswiring can break the Auto switch depending on the miswired circuit. 

•Do not connect wires while the power is on. 

Otherwise it can break the circuit inside the Auto switch causing malfunction. 

•Do not lay wires or cables with power cable or high-voltage cable in the same wiring route. 

Lay the wires to the Auto switch to a wire duct or in a protective tube other than those for power cables or 
high-voltage cables to prevent contamination with noise or induced surge voltage from power lines or high-voltage 
lines. 

•Verify the insulation of wiring. 

Poor insulation (interference with other circuit, poor insulation between terminals and etc.) can introduce excess 
voltage or current to the Auto switch causing damage. 

•Keep wiring as short as possible to prevent contamination from noise and induced surge voltage.   

Do not use a cable longer than 100 m. 

 

Environment 

•Never use the product for a corrosive gas or liquid. 

It can cause failure or malfunction. 

•Do not use the product in a place where strong magnetic field exists. 

It can cause a malfunction of the Auto switch, or demagnetization of a magnet inside actuator. 

•Do not use the Auto switch in an environment where the Auto switch is always splashed with

 

water 

drips. 

It can cause poor insulation or malfunction due to swelling of a resin filled inside the Auto switch. 

•Do not use the product in an atmosphere containing oils or chemicals. 

Use of the Auto switch in an atmosphere containing various oils or chemicals such as coolant or detergent can 
result in giving bad influence (poor insulation, malfunction die to swelling of a resin filled inside the Auto switch, or 
hardening of lead wires) even if in a short operating period. 

•Do not use the product in an atmosphere where steel dusts accumulate or magnetic bodies are 

gathered closely. 

When an amount of steel chips or steel dusts such as sputters of welding accumulate around an actuator equipped 
with Auto switch, or magnetic bodies (those attracted by magnet) are gathered closely to the actuator, they can 
weaken a magnet inside the actuator causing inoperativeness of the Auto switch. 

•Do not use the product in an environment where heat cycle exists. 

Heat cycles other than ordinary change of the temperature can affect the inside of Auto switch. 

•Do not use the Auto switch nearby a place where electric surges are generated. 

Internal circuit elements of Auto switch can deteriorate or break when equipment generating a large surge 
(electromagnetic lifter, high frequency induction furnace, motor, etc.) is located near

 

the Auto switch. Provide surge 

preventives, and avoid interference. 

•Do not use a load generating surge voltage. 

Use Auto switch equipped with surge absorber when a surge-generating load such as a relay or solenoid valve is 
driven directly. 

Summary of Contents for D-S7 Series

Page 1: ...No D S OMB0023 B PRODUCT NAME Solid State Auto Switch MODEL Series Product Number D S9 D T99 D S7 D T79...

Page 2: ...afety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 11 Definition and terminology 11 Mounting and Installation 12 Installation 12 Circuit diagram 14 Troubleshooting 15 Sp...

Page 3: ...equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly...

Page 4: ...responsibility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the...

Page 5: ...outside of the specifications Do not use for flammable or harmful fluids Fire malfunction or damage to the product can result Verify the specifications before use Do not operate in an atmosphere cont...

Page 6: ...Auto switches mounted parallel with each other keep 40 mm or more between actuator tubes to prevent influence malfunction due to magnetic interference Keep the allowable displacement for each Auto swi...

Page 7: ...xists It can cause a malfunction of the Auto switch or demagnetization of a magnet inside actuator Do not use the Auto switch in an environment where the Auto switch is always splashed with water drip...

Page 8: ...their instructions Turn the power on after connecting a load Otherwise it can cause excess current causing instantaneous breakage of the Auto switch Maintenance Perform maintenance and check regularl...

Page 9: ...8 No D S OMB0023 B Model Indication and How to Order...

Page 10: ...ons Insert the connector until the sleeve hit the switch so that projected part of the connector engage the groove of inserted portion Tighten the tightening ring afterwards Water tightness may be det...

Page 11: ...10 No D S OMB0023 B D S991 D S9P1 D T991 D S99V1 D S9PV1 D T99V1 The description of parts is consistent regardless of the type of switch The drawing above is the right handed type...

Page 12: ...ding of the output to other machines Internal voltage drop The voltage applied between the COM and signal line when the Auto switch turns on Current leakage The current flowing to the load when the Au...

Page 13: ...e the clamp for actuator after confirms that the actuator built in magnet Proper tightening torque The tightening torque of the M3 mounting screw must be 0 5 Nm 5 1 kgf cm D S79 D S7P D T79 D T79C 1 A...

Page 14: ...ng block A moves inside the groove move it to the mounting position beforehand After the actuated position has been adjusted with the cross recessed round head screw 1 use the auto switch Setting the...

Page 15: ...d load are separate D S7P D S9P V D T79 C D T99 V Sink input mode D T79 C D T99 V Source input mode The number marked on each lead wire color shows the pin number of pre wired connector PLC connector...

Page 16: ...urn on The operation LED doesn t light up The operation LED doesn t go off Switch failure Misapplication Switch failure Trouble No 7 The operation LED doesn t light up The operation LED doesn t go off...

Page 17: ...agnetic shield between cylinders Incorrect setting mounting position Short stroke Check if the condition is as below Switch operation range Piston stroke Displace the switch set position from the oper...

Page 18: ...e conductor Strong magnet Use the shield between magnetic field generating source and cylinder Influence of magnetic field of adjacent cylinder 20 mm or less Keeps cylinder away 40 mm or more Use magn...

Page 19: ...lead wire Bend radius Tensile force to lead wire Correct wiring Correct tensile force increase bend radius Malfunction due to turbulence magnetic field Presence of magnetic field generating source aro...

Page 20: ...40 mA or less 2 5 to 40 mA Internal voltage drop 0 8 V or less at load current of 10 mA 2 V or less at load current of 40 mA 4 V or less Current leakage 100 A or less at 24 VDC 0 8 mA or less Indicat...

Page 21: ...20 No D S OMB0023 B Dimensions D S791 D S7P1 D T791 D S792 D S7P2 D T792...

Page 22: ...21 No D S OMB0023 B D T791C D T792C...

Page 23: ...22 No D S OMB0023 B D S991 D S9P1 D T991 D S992 D S9P2 D T992...

Page 24: ...23 No D S OMB0023 B D S99V1 D S9PV1 D T99V1 D S99V2 D S9PV2 D T99V2...

Page 25: ...24 No D S OMB0023 B Pre wired connector D APC D BPC D DPC...

Page 26: ...vision July 2019 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and an...

Reviews: