background image

Trimmer Auto Switch

Safety Instructions

Note 1) ISO 4414: Pneumatic fluid power -- General rules relating to systems

Note 2) JIS B 8370: Pneumatic system axiom

Warning

Caution : 

Operator error could result in injury or equipment damage.

Warning : 

Operator error could result in serious injury or loss of life.

Danger : 

In extreme conditions, there is a possible result of serious injury or loss of life.

These safety instructions are intended to prevent a hazardous situation and/o
equipment damage. These instructions indicate the level of potential hazard by a
label of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe
ISO 4414 

Note 1)

, JIS B 8370 

Note 2)  

and other safety practices.

1. 

The compatibility of pneumatic equipment is the responsibility of the person 

who designs the pneumatic system or decides its specifications.

Since the products specified here are used in various operating conditions, their compatibility with the 

specific pneumatic system must be based on specifications or after analysis and/or tests to meet your 

specific requirements. The expected performance and safety assurance will be the responsibility of the 

person who has determined the compatibility of the system. This person should continuously review the 

suitability of all items specified, referring to the latest catalogue information with a view to giving due 

consideration to any possibility of equipment failure when configuring a system.

2. 

Only trained personnel should operate pneumatically operated machinery and 

equipment.

Compressed air can be dangerous if handled incorrectly. Assembly, handling or maintenance of 

pneumatic systems should be performed by trained and experienced operators.

3. 

Do not service machinery/equipment or attempt to remove components until 

safety is confirmed.

1. Inspection and maintenance of machinery/equipment should only be performed after confirmation of 

safe locked-out control positions.

2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply 

pressure for this equipment and exhaust all residual compressed air in the system.

3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston 

rod, etc. (Bleed air into the system gradually to create back pressure.)

4. 

Contact SMC if the product is to be used in any of the following conditions:

1. Conditions and environments beyond the given specifications, or if product is used outdoors.

2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical 

equipment, food and beverages, recreation equipment, emergency stop circuits, press applications, or 

safety equipment.

3. An application which has the possibility of having negative effects on people, property, and therefore 

requires special safety analysis.

Summary of Contents for D-F7K

Page 1: ...actuator OUT1 Trimmer OUT2 Trimmer Operating range of sensor LED of sensor is on OUT1 Detecting range Output ON Green LED is on Adjustable by trimmer Adjustable by trimmer Large work piece Medium work piece Small work piece OUT2 Detecting range Output ON Orange LED is on OUT1 and OUT2 are adjustable separately Can be mounted on a standard actuator Amplifier two types of mountin Large work piece Me...

Page 2: ...nt Response time Status indication Electrical entry Connection to sensor Power supply output cable Lead wire Impact resistance Insulation resistance Withstand voltage Ambient temperature D F7K D Y7K For relay and PLC 12 to 24 VDC 40 mA or less NPN open collector Two outputs 28 VDC or less 80 mA or less 1 5 V or less 100 µA or less 1 ms or less e con connector Grommet Oil proof vinyl heavy insulati...

Page 3: ... Adjustment must be undertaken while the sensor unit is removed from the actuator Refer to the operation manual for details Sensor unit 1 Indicator light Red light turns ON when sensor detects the magnet field Green light is ON durin the suitable position to detect the magne field including most sensitive position ø3 2 mounting hole M2 5 x 4L slotted set screw Fixes the sensor to the actuator 2 D ...

Page 4: ...46 5 5 12 5 7 7 2 6 3000 ø3 5 21 1 6 30 OUT1 OUT2 READY TRIMMER SWITCH SMC D RNK 2 ø3 5 SMC D F7K Most sensitive position D Y7K Most sensitive position SMC M2 5 x 4L 11 1 7 15 4 23 8 3 2 6 2 8 5 4 6 3000 2 5 6 2 33 2 5 10 6 0 4 ø3 5 ø3 2 ø3 5 12 5 3000 Connector for sensor e con ...

Page 5: ...latest catalogue information with a view to giving due consideration to any possibility of equipment failure when configuring a system 2 Only trained personnel should operate pneumatically operated machinery and equipment Compressed air can be dangerous if handled incorrectly Assembly handling or maintenance of pneumatic systems should be performed by trained and experienced operators 3 Do not ser...

Page 6: ... unit and 98m s2 or more for amplifier un while handling Although the body of the switch may not be damaged th inside of the switch could be damaged and cause malfunction 2 Do not carry a cylinder by the auto switc lead wires Never carry a cylinder by its lead wires This may not on break the lead wires but it may cause internal elements of th switch to be damaged by the stress 3 Mount switches usi...

Page 7: ...micals Consult SMC if auto switches will be used in an environment with coolant cleaning solvent various oils or chemicals If auto switches are used under these conditions for even a short time they may be adversely affected by improper insulation malfunction due to swelling of the potting resin or hardening of the lead wires 5 Do not use in an environment with temperature cycles Consult SMC if sw...

Page 8: ...ors please consult the manufacturers of the respective connectors 1 2 3 4 Part A 1 2 3 4 20mm or more Sheath Insulator Connector no 1 2 3 4 Wire core colour Black SOUT1 Blue GND White SOUT2 Brown Vsw Manufacturer Tyco Electronics AMP Part no 1473562 4 Manufacturer OMRON Corporation IDEC IZUMI Corporation Part no PFP M BNL6 Washer M3 x 16L Claw 2 OUT1 OUT2 TRIMMER SWITCH READY SMC OUT1 OUT2 TRIM ME...