5.
Pneumatic circuit
The typical circuit for CJP2 series where air filter, regulator, solenoid valve and speed controller (meter-out) are
used for operation is as follows.
W
) (
) (
Pressure
source
Drain catch
Air filter
Mist separator
Regulator
Air tank
Pressure
gauge
Solenoid
valbe
Air cylinder
Speed