background image

16 MPa

ISO Standard Hydraulic Cylinder

Ø 32, Ø 40, Ø 50, Ø 63, Ø 80, Ø 100

CHSG 

Series

CH D SG B 40

∗ 

Select an applicable auto switch model from 

   the table below. 

Magnet for auto

switch

Series type

Mounting type

Bore size

B

LA
FY

FZ

CA
CB

TA
TC

Basic

Transaxial foot type

Rod rectangular flange type

Head rectangular flange type

Single clevis

Double clevis

Rod trunnion

Centre trunnion

Number of auto 

switches

S
n

2 pcs.

1 pc.

"n" pcs.

Auto switch

Stroke

Without auto switch

D

Without

Built-in

Symbol

G

Nominal pressure

16 MPa

32
40
50
63
80

100

32 mm

40 mm

50 mm

63 mm

80 mm

100 mm

Port thread

type

TN

TF

Rc

NPT

GF

100

M9BW

Table 1  Manufacturability Check List by 
 

Mounting Type and  Port Position

Cylinder suffix

A

N
R
H

Without rod end nut

With rod end nut

With cushion on both sides

Without cushion

With front bumper

With rear bumper

Rod end

nut

Symbol

A

B

C

D

E

Position

Port on

top,

cushion

valve on

the right

Port on

top,

cushion

valve on

the left

Port on

top,

cushion

valve
down

Port on

the right,

cushion

valve on

top

Port on

the right,

cushion

valve on

 the left

Port on

the right,

cushion

valve
down

Port and cushion valve

location viewed from

the side of piston rod

end thread

Port position

Note 1) Refer to table 1 for manufacturability.
Note 2) Diagrams illustrate the view from the rod 
             on the left side of the cylinder dimensions. 
Note 3) For mounting types FY, FZ, or TA, indicate 
             port position with the symbol B.

Piping port

Cushion valve

Built-in Magnet Cylinder Model 

If a built-in magnet cylinder without auto 
switch is required, there is no need to enter 
the symbol for the auto switch.
(Example) CHDSGB50-100

Special

function

T

ype

Elec-

trical

entry

Grommet

Grommet

Wiring

(output)

3-wire (NPN equiv.)

2-wire

Load voltage

100 V

100 V or less

100 V, 200 V

200 V or less

AC

Ø 32 Ø 40 to Ø 80 Ø 100

DC

Lead wire length (m)

Relay
PLC

Applicable

load

Applicable Auto Switches/

Refer to website: 

www.smc.eu

 for further details on each auto switch.

5 V

12 V

5 V, 12 V

12 V

5 V, 12 V

12V

5 V, 12 V

12 V

5 V, 12 V

24 V

Yes

No

Yes

No

Yes

Diagnostic indication

(2-colour indicator)

Water resistant

(2-colour indicator)

Yes

24 V

24 V

Relay
PLC

Auto switch

model

Z76
Z73
Z80

A54
A64

A59W

M9N

M9P

M9B

M9NW

M9PW

M9BW

M9NA

∗∗

M9PA

∗∗

M9BA

∗∗

F59

F5P

J59

F59W

F5PW

J59W

F5BA

F59F

Pre-

wired

con-

nector

0.5

(—)

3

(L)

1

(

M

)

5

(Z)

Reed auto s

witc

h

Solid state auto s

witc

h

Indicator light

How to Order

Refer to the standard 

stroke table on the next page 14.

Presence

of cusion

Note) When more than one symbol is to be specified, 

indicate them in alphabetical order.

A
B
C
D
E

B

LA

FY
FZ

TA TC

CA
CB

Port
position

Mounting

bracket

    : Standard product       : Made to Order
    : Not available due to size limitation.

3-wire (NPN)

3-wire (PNP)

2-wire

3-wire (NPN)

3-wire (PNP)

2-wire

3-wire (NPN)
3-wire (PNP)

2-wire

4-wire (NPN)

IC

circuit

IC

circuit

IC

circuit

IC circuit
IC circuit

IC circuit

 Lead wire length symbols:  0.5 m  ······  —  (Example) M9NW

 

   1 m  ······  M  (Example) M9NWM

 

   3 m  ······  L 

(Example) M9NWL

 

   5 m  ······  Z 

(Example) M9NWZ

∗∗ 

Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance. 
Consult with SMC regarding water resistant types with the above model numbers.

∗ 

Solid state auto switches marked with “    ” are 

  produced upon receipt of order.

∗ 

Besides the models in the above table, there are some other auto switches that are applicable. For more information, refer to 

page 22.

 For details about auto switches with pre-wired connector, refer to website: 

www.smc.eu

.

 D-M9

, M9

W, M9

A, Z7

, Z80 auto switches are shipped together, (not assembled). (Only auto switch mounting brackets 

are packed assembled.)

Diagnostic output (2-colour indicator)

Diagnostic output (2-colour indicator)

13

Summary of Contents for CHSD Series

Page 1: ...HSG Series Nominal pressure 16 MPa Bore size mm 32 40 50 63 80 100 CHSD Series Nominal pressure 10 MPa Bore size mm 40 50 63 80 100 ISO Standard Hydraulic Cylinder EMC CHSD CHSG 01A UK CHSD CHSG Serie...

Page 2: ...rojection area 76 or less Reduced overall length CHSD Basic CH2 A Stroke A Stroke CHSD CHSG CH2 Maximum weight no more than 50 or 52 of CH2 series Cylinder with built in cover and mounting bracket all...

Page 3: ...ut in such case SMC cannot guarantee water resistance Consult with SMC regarding water resistant types with the above model numbers Special function Type Elec trical entry Grommet Grommet Wiring outpu...

Page 4: ...60 2 50 2 30 2 10 0 06 50 3 20 3 60 3 80 3 80 3 50 3 40 0 09 63 5 10 5 50 5 90 6 00 6 10 5 40 0 13 80 8 90 9 70 10 1 10 0 9 90 9 40 0 21 100 14 5 16 0 16 0 16 4 16 2 15 5 0 32 Unit kg Bore size mm Sp...

Page 5: ...teel Alloy steel Carbon steel Alloy steel Bearing steel Parts List Bore size mm 40 50 63 80 100 Seal kit no CHSD40 PS CHSD50 PS CHSD63 PS CHSD80 PS CHSD100 PS Replacement Parts Seal Kit Retaining ring...

Page 6: ...1 5 M27 x 2 M33 x 2 M42 x 2 S 107 108 115 133 146 P 3 8 3 8 1 2 1 2 3 4 NB 29 28 5 33 32 42 NA 46 46 5 46 57 58 M J M6 x 1 M8 x 1 M8 x 1 M10 x 1 25 M14 x 1 5 GB 16 16 18 17 22 GA 33 34 31 42 38 F 12...

Page 7: ...118 143 162 FY 40 50 56 70 90 FX 70 86 98 119 138 FD 6 6 9 9 11 13 5 BB 52 65 77 96 115 E 34 42 50 60 72 G 19 24 30 41 50 D 22 28 36 45 56 A 22 28 36 45 56 F 12 15 19 13 16 C 40 50 58 75 90 B 52 65 7...

Page 8: ...M10 x 1 25 M14 x 1 5 GB 16 16 18 17 22 GA 33 34 31 42 38 G 19 24 30 41 50 D 22 28 36 45 56 A 22 28 36 45 56 F 12 15 19 13 16 CD 14 14 20 20 28 B 52 65 77 96 115 RR 17 17 29 29 34 S 107 108 115 133 146...

Page 9: ...TH 050 NTH 060S NTH 080S NTH 100S d M16 x 1 6 M20 x 1 5 M27 x 2 M33 x 2 M42 x 2 40 50 63 80 100 H 10 12 16 20 25 B 22 27 41 50 65 C 25 4 31 2 47 3 57 7 75 D 21 26 39 48 62 Material Carbon steel H D 30...

Page 10: ...D A59W D Z7 Z80 40 4 5 4 8 50 5 4 5 9 63 6 4 5 10 5 14 10 Bore size mm 80 7 5 5 5 12 16 12 100 9 5 5 14 5 18 14 5 Auto switch model n 2 4 6 8 Note 1 n 2 2 n 2 4 6 8 Note 1 n 2 2 n 2 4 6 8 Note 1 n 2...

Page 11: ...ess steel screws are used Also when switches are shipped separately BBA1 is included Note 3 When using D M9 A V order stainless mounting screw kit BBA1 instead of the iron auto switch mounting bracket...

Page 12: ...htening torque to be 0 05 to 0 15 N m As a guide turn 90 from the position where it comes to feel tight Applicable auto switch Solid state D M9N V D M9P V D M9B V D M9NW V D M9PW V D M9BW V D M9NA V D...

Page 13: ...re to put the auto switch on the surface of cylinder tube 3 When changing the detecting position loosen the set screw to move the auto switch and then re fix the auto switch on the cylinder tube Tight...

Page 14: ...oad voltage 100 V 100 V or less 100 V 200 V 200 V or less AC 32 40to 80 100 DC Lead wire length m Relay PLC Applicable load Applicable Auto Switches Refer to website www smc eu for further details on...

Page 15: ...rea mm2 16 12864 8784 20096 14016 31408 21552 49872 33584 80416 54976 125648 86240 10 8040 5490 12560 8760 19630 13470 31170 20990 50260 34360 78530 53900 7 5628 3843 8792 6132 13741 9429 21819 14693...

Page 16: ...teel Stainless steel Stainless steel Carbon steel Carbon steel Copper alloy Carbon steel Chromium molybdenum steel Carbon steel Alloy steel Carbon steel Alloy steel Bearing steel Parts List Descriptio...

Page 17: ...50 63 80 100 Stroke range Bore size mm PJ Stroke Z Stroke ZA Stroke S Stroke ZZ Stroke Cushion valve 32 40 50 63 80 100 25 to 800 25 to 800 25 to 800 25 to 800 25 to 800 25 to 1000 32 40 50 63 80 100...

Page 18: ...Z 70 110 130 145 180 200 FY 33 41 52 65 83 97 FX 58 87 105 117 149 162 FD 6 6 11 14 14 18 18 BB 45 63 75 90 115 130 E 30 34 42 50 60 72 G 14 19 24 30 41 50 D 18 22 28 36 45 56 A 18 22 28 36 45 56 F 12...

Page 19: ...V 5 5 6 5 7 12 15 15 Y 60 62 67 71 77 82 ZZ 182 211 248 265 308 363 S 103 128 134 136 159 168 0 062 0 Stroke range Bore size mm ZZ Stroke SS Stroke S Stroke Air release Cushion valve PJ Stroke 32 40 5...

Page 20: ...8 22 28 36 45 56 A 18 22 28 36 45 56 F 12 12 9 13 9 10 C 33 2 41 7 52 3 64 3 82 7 96 9 B 44 61 75 87 112 125 0 020 0 053 0 025 0 064 0 016 0 043 Stroke range Bore size mm SS 1 2 Stroke PJ Stroke ZZ St...

Page 21: ...6 M20 x 1 5 M27 x 2 M33 x 2 M42 x 2 32 40 50 63 80 100 H 8 10 12 16 20 25 B 22 22 27 41 50 65 C 25 4 25 4 31 2 47 3 57 7 75 D 21 21 26 39 48 62 H D 30 d B C Accessory Option Rod end nut Material Carb...

Page 22: ...conditions in the actual setting D M9 M9 V M9 W M9 WV M9 A M9 AV cannot be mounted to 100 D A5 A6 A59W Z7 Z80 cannot be mounted to 32 Since this is a guideline including hysteresis not meant to be gu...

Page 23: ...8 12 16 Note 4 n 4 8 12 16 Note 4 n 4 8 12 16 Note 4 n 4 8 12 16 Note 4 n 4 8 12 16 Note 4 n 4 8 12 16 Note 4 n 4 8 12 16 Note 4 n 4 8 12 16 Note 4 n 4 8 12 16 Note 4 n 4 2 n 4 8 12 16 Note 4 n 4 8 12...

Page 24: ...on a cylinder the above stainless steel screws are used Also when switches are shipped separately BBA1 is included Note 4 When using D M9 A V order stainless mounting screw kit BBA1 instead of the iro...

Page 25: ...que to be 0 05 to 0 15 N m As a guide turn 90 from the position where it comes to feel tight Applicable auto switch Solid state D M9N V D M9P V D M9B V D M9NW V D M9PW V D M9BW V D M9NA V D M9PA V D M...

Page 26: ...hexagonal wrench Be sure to put the auto switch on the surface of cylinder tube 3 When changing the detecting position loosen the set screw to move the auto switch and then re fix the auto switch on t...

Page 27: ...orbed energy E for a cylinder Maximum absorberd energy Draw a vertical line from the set pressure 7MPa the point where this line intersects with the line for 50 21J is the maximum absorbed energy E 21...

Page 28: ...00 1000 100 100 10 10 1 Max absorbing energy J 1 Set pressure MPa 2 4 6 8 10 12 14 16 1000 100 10 Max absorbing energy J 1 5 2J 21J 100 80 63 50 40 63 External force and energy conversion at cushion s...

Page 29: ...quipment damage will not occur upon restart of operation When the cylinder has to be reset at the starting position install manual safely equipment KHFN WKH VSHFLILFDWLRQV The products featured in thi...

Page 30: ...r on areas such as the inner tube surface bushings piston rod surface and seals Allow for decentering of the axis either by aligning the axis center or using a floating joint KHQ DQ H WHUQDO JXLGH LV...

Page 31: ...en erratic move ment of driven objects and equipment Then cut off the air supply and electric power and reduce the pressure in the system to zero When machinery is restarted proceed with caution after...

Page 32: ...ifications The voltage drop will be n times larger when n auto Design and Selection Auto switch operating range mm Load operating time ms x 1000 V mm s 6LPLODUO ZKHQ RSHUDWLQJ EHORZ D VSHFLILHG YROWDJ...

Page 33: ...g diode and make it inoperable Applicable models D A53 A54 D Z73 2 Note however in the case of 2 colour display type auto switch A59W if the wiring is reversed the switch will be in a normally ON cond...

Page 34: ...on and generate or cut off a signal momentarily 1 ms or less Consult with SMC regarding the need to use a solid state switch depending on the environment R QRW XVH LQ DQ DUHD ZKHUH VXUJHV DUH JHQ erat...

Page 35: ...of SMC products with production equipment for the manufacture of weapons of mass destruction WMD or any other weapon is strictly prohibited 2 The exports of SMC products or technology from one countr...

Page 36: ...hu Ireland 353 0 14039000 www smcautomation ie sales smcautomation ie Italy 39 03990691 www smcitalia it mailbox smcitalia it Latvia 371 67817700 www smc lv info smc lv Lithuania 370 5 2308118 www sm...

Reviews: