3. Application 

 

This product is designed to control the speed of a pneumatic actuator. 

 

4. Specifications 

WORKING FLUID 

AIR 

WORKING PRESS.RANGE 

0~1MPa 

PROOF PRESS 

1.5MPa 

AMBIENI TEMP. AND WORKING FLUID TEMP. 

-5~60℃(NO FREEZING) 

 

5

  Troubleshooting

 

 

Trouble 

Possible cause 

Countermeasures 

The speed (flow 
rate) cannot be 
controlled.   

Dust inside 

Fully open the needle and apply air blow 
from the screw. If the problem in not 
solved even after air blow, install an air 
filter to the piping, and replace the 
product with a new one.       

 

 
6

  Construction                 

 

ASN2-M5,U10/32            ASN2-01~04 
                                          ASN2-N01~N04 

 

     

 

 
     

                                               

 

                               

 

No.

Description

Material

1

Handle

PBT

2

Needle

Brass

3

Lock nut

Steel wire

4

Needle guide

Brass

5

Washer

Steel

6

Cover

PE

7

O ring

NBR

8

Sponge

PVA Sponge

9

Body B

Brass

10

Gasket

NBR/Stainless

Remarks

Electroless nickel plating

Electroless nickel plating

M5,U10/32

Electroless nickel plating

Summary of Contents for ASN2 Series

Page 1: ...Doc no AS OMP0006 B PRODUCT NAME METERING VALVE WITH SILENCER MODEL Series Product Number ASN2 Series...

Page 2: ...Contents 1 Safety Instructions 2 3 2 Specific Product Precautions 4 6 3 Application 7 4 Specifications 7 5 Troubleshooting 7 6 Construction 7 1...

Page 3: ...ty of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorre...

Page 4: ...a replacement product or necessary parts will be provided This limited warranty applies only to SMC product independently and not to any other damage incurred due to the failure of the product 3 Prior...

Page 5: ...se any adverse effects on the system Please contact SMC if the Safety Data Sheet SDS is required 6 Example of inapplicable circuits Warning 1 Operation Manual Install the product and operate it only a...

Page 6: ...er than compressed air 2 When there is a large amount of drainage Compressed air containing a large amount of drainage can cause malfunction of pneumatic equipment An air dryer or water separator shou...

Page 7: ...amage of machinery and equipment may occur 2 Maintenance work If handled improperly compressed air can be dangerous Assembly handling repair and element replacement of pneumatic systems should be perf...

Page 8: ...de Fully open the needle and apply air blow from the screw If the problem in not solved even after air blow install an air filter to the piping and replace the product with a new one 6 Construction AS...

Page 9: ...iyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manu...

Reviews: