background image

- 5 - 

 

 

 

 

Caution

 

(1) First, tighten the fitting by hand, then use a 

suitable  wrench  to  tighten  the  hexagonal 
portion of the body a further two or three turns. 
For  the  reference  value  for  the  tightening 
torque,  refer  to  the  table  below.  Check  the 
dimensions  of  each  product  for  the  width 
across flats. 

 

 
 
 
 
(2) M5 and 10-32 UNF 
   

First,  tighten  it  by  hand,  then  give  it  an  additional 

1/6  turn  to  1/4  turn  with  a  wrench.  The  reference 
value for the tightening torque is 1 to 1.5N

m. 

 

Excessive  tightening  may  damage  the  thread 

portion or deform the gasket and cause air leakage. 
If the screw is too shallowly screwed in, it may come 
loose or air may leak.   

(3)Chamfered  female  thread  size  of  the 
connection thread M5, 10-32UNF 
   

In  compliance  with  ISO16030  Standards  (air 
pressure  fluid  dynamics 

–  connection  –  ports  and 

stud  ends),  the  chamfered  thread  sizes  shown 
below are recommended. 

 
 
 
 
 
 

(4)  The  proper  tightening  torques  for  hexagon 
lock  nuts  are  shown  in  the  table  below.  For 
standard  installation,  turn  15  to  30

°

using  a 

tool, after fastening by hand.   
Pay attention not to over tighten the product for 
the width across flats. 
 
 

 
 
 
 

 

           

Caution 

(1) Preparation before piping 

 

Before  piping  is  connected,  it  should  be 

thoroughly blown out with air (flushing) or washed 
to remove chips, cutting oil, and other debris from 
inside the pipe. 

 
 
 

 
 

Caution

 

(2) Winding of sealant tape 

When screwing piping or fittings into ports, ensure 
that chips from the pipe threads or sealing material 
do not enter the piping. Also, if sealant tape is used, 
leave 1 thread ridge exposed at the end of the 
threads. 

 

 

   

   

Warning 

 

(1) Type of fluids 

Please consult with SMC when using the product 
in applications other than compressed air. 

(2) When there is a large amount of drainage 

   

Compressed  air  containing  a  large  amount  of 

drainage  can  cause  malfunction  of  pneumatic 
equipment. An air dryer or water separator should 
be installed upstream from filters. 

(3) Drain flushing 

 

If condensation in the drain bowl is not emptied on 

a  regular  basis,  the  bowl  will  overflow  and  allow 
the  condensation  to  enter  the  compressed  air 
lines.  This  causes  malfunction  of  pneumatic 
equipment.   
If  the  drain  bowl  is  difficult  to  check  and  remove, 
the  installation  of  a  drain  bowl  with  an  auto  drain 
option is recommended. 

For  compressed  air  quality,  refer  to  the  Best 
Pneumatics No.6 catalog. 

(4) Use clean air. 

Do  not  use  compressed  air  that  contains 
chemicals,  synthetic  oils  that  include  organic 
solvents, salts or corrosive gases, etc., as it can 
cause damage or malfunction. 

     

Caution 

(1) Install an air filter. 

Install  an  air  filter  upstream  near  the  valve. 
Select an air filter with a filtration size of 5μm or 
smaller. 

(2) Take measures to ensure air quality, such 

as by installing an aftercooler, air dryer, or 
water separator. 

Compressed  air  that  contains  a  large  amount 

of  drainage  can  cause  the  malfunction  of 
pneumatic  equipment,  such  as  flow  control 
equipment. 

Therefore, 

take 

appropriate 

measures  to  ensure  air  quality,  such  as  by 
providing  an  aftercooler,  air  dryer,  or  water 
separator. 

  (3)  Ensure  that  the  fluid  and  ambient 

temperatures  air  within  the  specified 
range. 

       

If  the  fluid  temperature  is  5

  or  less,  the 

moisture  in  the  circuit  could  freeze,  causing 
damage  to  the  seals  or  leading  to  equipment 
malfunction. 

Therefore, 

take 

appropriate 

measures to prevent freezing. For compressed 
air  quality,  refer  to  the  Best  Pneumatics  No.6 
catalog. 

Female thread size 

Chamfered port size  ΦD 

  (Recommended value) 

M5 

3.1 to 3.4 

10-32UNF 

5.1 to 5.3 

Air Supply 

Piping 

Mounting 

 

Piping 

Summary of Contents for ASN2 Series

Page 1: ...Doc no AS OMP0006 B PRODUCT NAME METERING VALVE WITH SILENCER MODEL Series Product Number ASN2 Series...

Page 2: ...Contents 1 Safety Instructions 2 3 2 Specific Product Precautions 4 6 3 Application 7 4 Specifications 7 5 Troubleshooting 7 6 Construction 7 1...

Page 3: ...ty of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorre...

Page 4: ...a replacement product or necessary parts will be provided This limited warranty applies only to SMC product independently and not to any other damage incurred due to the failure of the product 3 Prior...

Page 5: ...se any adverse effects on the system Please contact SMC if the Safety Data Sheet SDS is required 6 Example of inapplicable circuits Warning 1 Operation Manual Install the product and operate it only a...

Page 6: ...er than compressed air 2 When there is a large amount of drainage Compressed air containing a large amount of drainage can cause malfunction of pneumatic equipment An air dryer or water separator shou...

Page 7: ...amage of machinery and equipment may occur 2 Maintenance work If handled improperly compressed air can be dangerous Assembly handling repair and element replacement of pneumatic systems should be perf...

Page 8: ...de Fully open the needle and apply air blow from the screw If the problem in not solved even after air blow install an air filter to the piping and replace the product with a new one 6 Construction AS...