2. Application
This product aims at eliminating oil aerosol and solid foreign matter in the air line.
3. Standard specifications
- Flow capacity, inlet pressure, and the amount of solid or liquid particles on the filter inlet side are stable.
- New element
- Oil aerosol concentration on the filter inlet side = 10mg/m
3
- Inlet air temperature: 25
o
C
- Flow capacity, inlet pressure, and the oil aerosol concentration on the filter inlet side are stable.
- New element
-7-
Note2) Conditions in accordance with [Test method ISO 12500-1:2007 compliant] in addition to the conditions above.
Note1) Conditions in accordance with [Test method ISO 12500-3:2009 compliant] in addition to the conditions above.
The compressed air quality class on the inlet side is [4:7:4].
Note4) Based on ISO8573-1:2010 Compressed air - Part1: Contaminants and purity classes.
Note3) Inlet pressure: 0.7 MPa Flow rate at 20
o
C, atmospheric pressure, and 65% of relative humidity.
AM50
AM60
3/4
,
1
1
N.C.
N.O.
2200L/min(ANR)
3700L/min(ANR)
1.23kg
1.46kg
Model No.
Port size
Fluid
Ambient and operating fluid temperature
Air
-5 to 60
o
C (No freezing)
Max. operating pressure
1.5MPa
1.0MPa
Stainless steel
(99% filtered particle size)
1mg/m
3
ISO8573-1:2010[2:7:3]
100cm
3
0.15MPa
0.1MPa
0.1
μ
m
Proof pressure
Min. operating
pressure of auto drain
Outlet side oil aerosol concentration
Note2)
Nominal filtration rating
Note1)
Drain capacity
Max. air flow capacity
Note3)
Compressed air purity class
Note4)
Bowl material
Weight