Air Source

 

       

Warning

 

1)  Use clean air. Do not use compressed air containing chemicals, organic solvent, synthetic oil or 

corrosive gas as it may be cause of breakage of components or operation failure.   

2)  Air containing too much moisture may deteriorate the performance. Install the refrigerated air dryer 

or aftercooler before the mist separator. 

3)  Make sure that the supply pressure is not below the minimum operating pressure. If it is used at the 

minimum operating pressure or less, pressure resistance increases, leading to the decrease of 
operation life or operation failure.   

 

       

Caution

 

1)  Install the air filter AF series or line filter AFF series as a pre-filter to the inlet of the product in order to 

avoid the clogging of early stage.   

 
 

Maintenance

 

       

Warning

 

1)  Release the pressure in the product to the atmosphere when replacing parts or removing piping.   
2)  Maintenance and checks should be done by following the procedure in the operation manual. 

Incorrect handling of the product may cause breakage or operation failure of the equipment or 
device.   

3)  Do not touch the product when operating at high temperature (40 to 60 

o

C). The operators may get 

burnt. Be sure to confirm that the temperature of the container or operating part is reduced to 40 

o

or less to prevent burns.   

4)  On a product with an element service indicator, perform regular checks to find cracks, scratches, or 

other deterioration of the indicator window. If any crack, scratch, and other defect is observed, 
replace the element service indicator with new a one because such a defect may cause the product 
to be broken. Investigate and/or review the operating conditions if necessary. 

5)  Check for dirt in the bowl periodically. If any dirt is seen, replace with new bowl. 
6)  Open and close drain cock by hand. The use of tools can result in damage to the product. 
7)  Replace the element before 2 years passed from start of use or pressure drop (difference between 

the inlet pressure and outlet pressure) reaches 0.1MPa. Or if the element is broken. 

 

       

Caution

 

1)  Check the element periodically and replace it with a new one if necessary. If it is found that outlet 

pressure drops or the flow is restricted, check the condition of the element.   

2)  For the N.C. type auto drain, when there is no pressure, condensate which does not operate the 

auto drain mechanism will remain in the bowl. It is recommended to release the residual condensate 
manually at the end of the working day.   

3)  Products with an element service indicator show a red indication as the element clogging 

progresses. Ensure that the element is replaced before the red indication reaches the upper limit. 

 
 

 

Summary of Contents for AM50-06-D

Page 1: ...Doc No AMX OMZ0093 PRODUCT NAME Mist Separator MODEL Series Product Number AM50 F N 06 F N 10 B C D J L R W Z D AM60 F N 10 B C D J L R W Z D...

Page 2: ...owl assembly for AM50 10 6 2 Bowl assembly for AM60 11 7 Assembly of Optional parts 12 8 Operation and Adjustment 13 to 14 8 1 Discharge from the product with drain cock 13 8 2 Manual drain discharge...

Page 3: ...ipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The...

Page 4: ...lure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded fr...

Page 5: ...t is mounted on the outlet of the product particles will be generated from the equipment and required cleanliness may not be obtained Instead install the air equipment at the inlet Caution 1 Applicati...

Page 6: ...ecommended torque while holding the female thread side tightly Insufficient tightening torque can cause loose piping or sealing failure Excess tightening torque may cause damage to threads If the fema...

Page 7: ...ner or operating part is reduced to 40 oC or less to prevent burns 4 On a product with an element service indicator perform regular checks to find cracks scratches or other deterioration of the indica...

Page 8: ...00 3 2009 compliant in addition to the conditions above The compressed air quality class on the inlet side is 4 7 4 Note4 Based on ISO8573 1 2010 Compressed air Part1 Contaminants and purity classes N...

Page 9: ...Flow direction Left to right R Flow direction Right to left Nil Pressure unit MPa Temp unit o C Z Pressure unit psi Temp unit o F Note2 Note2 Without mounting option With bracket Without auto drain Wi...

Page 10: ...semblyNote2 Note1 Note2 Assembly of the mounting bracket 2 types and set screw 2 pcs Refer to the 7 Assembly of Optional parts P12 for mounting the bracket assembly The numbers in the table and constr...

Page 11: ...4 How to Order P8 for option and semi standard symbols 10 J Appearance and Part No Appearance and Part No Appearance and Part No D Note2 C Note1 W Semi standard C Rc G NPT AM54P N120AS C Part No AM54...

Page 12: ...P8 for option and semi standard symbols 11 J Appearance and Part No Appearance and Part No Appearance and Part No D Note2 C Note1 W Semi standard C Rc G NPT AM64P N120AS C AM64P 120AS C Port thread t...

Page 13: ...r the tightening torque Insert bracket A from the front side of the product so that the finger of the bracket A engages with the groove and the bottom of the body Mounting of bracket A see drawing on...

Page 14: ...t with drain cock 13 Pressurize the inside of the mist separator when discharging drain Drain will not be discharged properly if not pressurized Drain cock AM50 AM60 Drain cock With barb fitting push...

Page 15: ...Drain will not be discharged properly if not pressurized To discharge the auto drain manually follow the procedure below After discharging the drain rotate the cock to the opposite direction by hand...

Page 16: ...gn matter is caught at the main valve of the auto drain Remove the dust by manual drain discharge P14 4 Main valve of the auto drain is broken Replace the bowl assembly P16 5 Drain piping is long or I...

Page 17: ...both fingers two locations of the bowl with the body 6 Install the flange to the body temporarily tighten four mounting screws and then tighten them diagonally and evenly to secure the flange AM50 AM6...

Page 18: ...bowl assembly by referring to the section 10 1 Bowl assembly Replacement P16 Assembly 2 Install the replacing element and bowl seal in the bowl assembly Mount the bowl assembly by referring to the sec...

Page 19: ...11 Disassembly Drawing 18 Body I N OUT AM50 AM60 Bowl seal Element Bowl assembly Mounting screws 4 pieces...

Page 20: ...2 52 5 259 2 AM60 1 90 314 8 32 45 30 45 70 66 40 5 11 13 113 3 2 52 5 336 3 Model No Option specifications With auto drain Bracket mount Standard specifications B B W AM50 246 2 244 5 64 3 AM60 323 3...

Page 21: ...u Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacture...

Reviews: