SNMP C
OMMANDS
4-153
Command Usage
• If you do not enter an
snmp host
command, no notifications are sent.
In order to configure the switch to send SNMP notifications, you must
enter at least one
snmp host
command. In order to enable multiple
hosts, you must issue a separate
snmp host
command for each host.
• The
snmp-server host
command is used in conjunction with the
snmp enable traps
command. Use the
snmp enable traps
command to specify which SNMP notifications are sent globally. For
a host to receive notifications, at least one
snmp enable traps
command and the
snmp host
command for that host must be
enabled.
• Some notification types cannot be controlled with the
snmp enable
traps
command. For example, some notification types are always
enabled.
• The switch can send SNMP version 1 or version 2c notifications to a
host IP address, depending on the SNMP version that the
management station supports. If the snmp-server host command does
not specify the SNMP version, the default is to send SNMP version 1
notifications.
Example
Related Commands
snmp enable traps (4-154)
Console(config)#snmp-server host 10.1.19.23 batman
Console(config)#