-98
Default Setting
IGMP Version 2
Command Mode
Global Configuration
Command Usage
• All systems on the subnet must support the same version. If there are
legacy devices in your network that only support Version 1, you will
also have to configure this switch to use Version 1.
• Some commands are only enabled for IGMPv2, including
ip igmp
query-max-response-time
and
ip igmp query-timeout
.
Example
The following configures the switch to use IGMP Version 1:
show ip igmp snooping
This command shows the IGMP snooping configuration.
Default Setting
None
Command Mode
Privileged Exec
Command Usage
See “Configuring IGMP Snooping and Query Parameters” on
page 3-193 for a description of the displayed items.
Console(config)#ip igmp snooping version 1
Console(config)#