background image

Summary of Contents for 8516T

Page 1: ......

Page 2: ......

Page 3: ...38 Tesla Irvine CA 92618 Phone 949 679 8000 EZ Switch 10 100 1000 User Guide From SMC s EZ line of low cost workgroup LAN solutions December 2003 Pub 150000009400H R01 ...

Page 4: ...from its use No license is granted by implication or otherwise under any patent or patent rights of SMC SMC reserves the right to change specifications at any time without notice SMC Networks Inc 38 Tesla Irvine CA 92618 All rights reserved Trademarks SMC is a registered trademark and EZ Switch is a trademark of SMC Networks Inc Other product and company names are trademarks or registered trademar...

Page 5: ...ncorporates these newer technologies At that point the obsolete product is discontinued and is no longer an Active SMC product A list of discontinued products with their respective dates of discontinuance can be found at http www smc com index cfm action customer_service_warranty All products that are replaced become the property of SMC Replacement products may be either new or reconditioned Any r...

Page 6: ...CIDENT FIRE LIGHTNING OR OTHER HAZARD LIMITATION OF LIABILITY IN NO EVENT WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE SHALL SMC BE LIABLE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE LOSS OF BUSINESS OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTIO...

Page 7: ...uit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help EC Conformance Declaration Class A SMC contact for these products in Europe is SMC Networks Europe Edificio Conata II Calle Fructuós Gelabert 6 8 2o 4a 08970 Sant Joan Despí Barcelona Spain This information technology equipment complies with the requirements of the Council D...

Page 8: ...gnetic field according to EN 61000 4 3 1996 80 1000 MHz with 1 kHz AM 80 Modulation 3 V m Electrical fast transient burst according to EN 61000 4 4 1995 AC DC power supply 1 kV Data Signal lines 0 5 kV Surge immunity test according to EN 61000 4 5 1995 AC DC Line to Line 1 kV AC DC Line to Earth 2 kV Immunity to conducted disturbances Induced by radio frequency fields EN 61000 4 6 1996 0 15 80 MHz...

Page 9: ...ional adjustments are necessary when connecting it to any input voltage within the range marked on the rear panel Operating Voltage Cord Set Specifications 120 Volts UL Listed CSA Certified Cord Set Minimum 18 AWG Type SVT or SJT three conductor cord Maximum length of 15 feet Parallel blade grounding type attachment plug rated 15 A 125 V 240 Volts Europe only Cord Set with H05VV F cord having thre...

Page 10: ...lten Sie es vom Stromnetz trennen Somit wird im Falle einer Überspannung eine Beschädigung vermieden 12 Durch die Lüftungsöffnungen dürfen niemals Gegenstände oder Flüssigkeiten in das Gerät gelangen Dies könnte einen Brand bzw elektrischen Schlag auslösen 13 Öffnen sie niemals das Gerät Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisiertem Servicepersonal geöffnet werden 1...

Page 11: ...electing a Site 4 Instructions 5 Application Example 7 Troubleshooting 8 Diagnosing Switch Indicators 8 Cables 9 Cable Specifications 9 10BASE T 100BASE TX Pin Assignments 9 1000BASE T Pin Assignments 10 1000BASE T Cable Requirements 11 Cable Testing for Existing Category 5 Cable 11 Adjusting Existing Category 5 Cabling 11 Product Specifications 12 EZ Switch 10 100 1000 12 ...

Page 12: ...TABLE OF CONTENTS viii ...

Page 13: ...uickest solution to meeting the growing demands on your network s limited resources Features and Benefits Auto negotiation supported on all ports Automatic MDI MDI X operation IEEE 802 3ab 802 3u and 802 3 compliance ensures compatibility with standards based hubs switches and cards from any vendor Store and forward switching ensures error free transmission Half and full duplex flow control preven...

Page 14: ...des status LEDs for at a glance system monitoring The following table details the functions of the various indicators Port and System Status LEDs LED Condition Status Power On The switch is receiving power Off The switch is not receiving power Ports Link Act On The port has established a valid network connection Off The port has not established a network connection Flashing Traffic is passing thro...

Page 15: ...he AC power receptacle is located on the rear panel of the switch 5 6 7 8 9 10 11 12 EZ Switch 10 100 1000 8516T Link Act Link Act 1000 100M 1000 100M Power 2 1 4 3 5 7 8 6 10 9 12 11 13 15 16 14 1 2 3 4 13 14 15 16 100 240V 50 60Hz 2A ...

Page 16: ...ting a Site Be sure to follow the site selection guidelines below when choosing a location Select a suitable location for the switch It should be accessible for installing cabling and maintaining the switch The temperature and humidity should be within the ranges listed in the specifications The status LEDs should be clearly visible EZ Switch 10 100 1000 SMC8516T Four rubber foot pads Rack mount b...

Page 17: ...wer Plug one end of the power adapter into the socket on the switch s rear panel and the other end into an appropriate electrical outlet Check the Power LED to be sure power is on Note It is not necessary to power off the switch before connecting or disconnecting any UTP cables as these actions will not disrupt the operation of other devices attached to the switch 3 Connecting PCs Connect each PC ...

Page 18: ...t through cable to connect to other switches or hubs from any port on the switch No crossover cables or other device settings are needed See the Cable Specifications on page 9 of this guide for further information Caution Do not plug a phone jack connector into any RJ 45 port This may damage the switch Instead use only twisted pair cables with RJ 45 connectors that conform with FCC standards ...

Page 19: ...tions LAN 1 PWR WLAN WAN 2 3 Link Activity Notebook Internet Notebook with SMC2835W Wireless PC Card SMC2804WBR Wireless Broadband Router Workstations With SMC9452TX Gigabit PCI Cards 5 6 7 8 9 10 11 12 EZ Swi tch 10 100 10 00 851 6T Link Ac t Link Ac t 1000 10 0M 1000 10 0M Power 2 1 4 3 5 7 8 6 10 9 12 11 13 15 16 14 1 2 3 4 13 14 15 16 ...

Page 20: ...ection is made Probable Causes Switch port network card or cable may be defective Possible Solutions Check that the switch and attached device are both powered on Be sure the network cable is connected to both devices Verify that Category 5 or better cable is used for 10 100 Mbps connections Category 5 or 5e cable for 1000 Mbps connections and that the length of any cable does not exceed 100 meter...

Page 21: ...any twisted pair connection does not exceed 100 meters 328 feet Because all ports on this switch support automatic MDI MDI X operation you can use straight through cables for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable Cable ...

Page 22: ...it Data plus TD 2 Receive Data minus RD Transmit Data minus TD 3 Transmit Data plus TD Receive Data plus RD 6 Transmit Data minus TD Receive Data minus RD 4 5 7 8 Not used at 10 100 Mbps Not used at 10 100 Mbps Pin MDI X MDI 1 Bi directional Data Two Plus BI_D2 Bi directional Data One Plus BI_D1 2 Bi directional Data Two Minus BI_D2 Bi directional Data One Minus BI_D1 3 Bi directional Data One Plu...

Page 23: ...pass tests for Attenuation Near End Crosstalk NEXT and Far End Crosstalk FEXT This cable testing information is specified in the ANSI TIA EIA TSB 67 standard Additionally cables must also pass test parameters for Return Loss and Equal Level Far End Crosstalk ELFEXT These tests are specified in the ANSI TIA EIA TSB 95 Bulletin The Additional Transmission Performance Guidelines for 100 Ohm 4 Pair Ca...

Page 24: ...s Communication Mode Full or half duplex at 10 100 Mbps Full duplex at 1000 Mbps Media Supported 10BASE T 100 ohm Category 3 or better twisted pair 100BASE TX 100 ohm 2 pair Category 5 or better twisted pair 1000BASE T 100 ohm 4 pair Category 5 5e twisted pair Indicator Panel Power Ports Link Act 100 1000M Dimensions 33 x 23 x 4 4 cm 12 99 x 9 06 x 1 73 in ...

Page 25: ...t Dissipation 130 BTU hr maximum Power Requirement Input Voltage 100 240 VAC 50 60 Hz Temperature Operating 0 40 ºC 32 98 ºF Storage 40 70 ºC 40 158 ºF Humidity 10 to 90 non condensing EMC Safety Compliances CE Mark Immunity EN 61000 4 2 3 4 5 6 8 11 Emissions FCC Class A CISPR Class A EN 61000 3 2 3 Safety CSA NRTL C22 2 950 UL 1950 TUV GS EN60950 IEC 950 ...

Page 26: ...PRODUCT SPECIFICATIONS 14 ...

Page 27: ......

Page 28: ...4 UK 44 0 1932 866553 Fax 44 0 118 974 8701 France 33 0 41 38 32 32 Fax 33 0 41 38 01 58 Italy 39 0 335 5708602 Fax 39 02 739 14 17 Benelux 31 33 455 72 88 Fax 31 33 455 73 30 Central Europe 49 0 89 92861 0 Fax 49 0 89 92861 230 Nordic 46 0 868 70700 Fax 46 0 887 62 62 Eastern Europe 34 93 477 4920 Fax 34 93 477 3774 Sub Saharian Africa 216 712 36616 Fax 216 71751415 North West Africa 34 93 477 49...

Reviews: