B
ASIC
C
ONFIGURATION
3-43
Web
– Select SNTP, Configuration. Modify any of the required
parameters, and click Apply.
Figure 3-21. SNTP Configuration
CLI
– This example configures the switch to operate as an SNTP unicast
client and then displays the current time and settings.
Setting the Time Zone
SNTP uses Coordinated Universal Time (or UTC, formerly Greenwich
Mean Time, or GMT) based on the time at the Earth’s prime meridian,
zero degrees longitude. To display a time corresponding to your local time,
you must indicate the number of hours and minutes your time zone is east
(before) or west (after) of UTC.
Command Attributes
•
Current Time
– Displays the current time.
•
Name
– Assigns a name to the time zone. (Range: 1-29 characters)
Console(config)#sntp client
4-71
Console(config)#sntp poll 60
4-72
Console(config)#sntp server 10.1.0.19 137.82.140.80 128.250.36.2
4-71
Console(config)#exit
Console#show sntp
Current time: Jan 6 14:56:05 2004
Poll interval: 60
Current mode: unicast
SNTP status : Enabled
SNTP server 10.1.0.19 137.82.140.80 128.250.36.2
Current server: 128.250.36.2
Console#
Summary of Contents for 6152L2
Page 2: ......
Page 18: ...TABLES xiv ...
Page 32: ...INTRODUCTION 1 10 ...
Page 46: ...INITIAL CONFIGURATION 2 14 ...
Page 185: ...PORT CONFIGURATION 3 139 Figure 3 61 Displaying Etherlike and RMON Statistics ...
Page 249: ...QUALITY OF SERVICE 3 203 Figure 3 90 Configuring Policy Maps ...
Page 290: ...CONFIGURING THE SWITCH 3 244 ...
Page 303: ...COMMAND GROUPS 4 13 VC VLAN Database Configuration ...
Page 434: ...COMMAND LINE INTERFACE 4 144 ...
Page 568: ...TROUBLESHOOTING B 4 ...
Page 581: ......