background image

LJ1H20

90

LEJS40

58

NEW

Series

Work load (kg)  Speed (mm/s) Motor output (W)

LEJS40

55

600

100

(Existing model)

LJ1H20

30

500

100

Work load: 

85

 

kg

Positioning repeatability: 

±

0.02

 

mm

Max. speed: 

1,800

 

mm/s

Max. acceleration/deceleration: 

20,000

 

mm/s

2

Max. stroke: 

3,000

 

mm

Max. speed: 

3,000

 

mm/s

Max. acceleration/deceleration: 

20,000

 

mm/s

2

Ball Screw Drive  

Series

 LEJS

Belt Drive  

Series

 LEJB

Size: 40, 63

Size: 40, 63

Series

 LECSA

Type

AC Servo Motor

Low-profile/

Low center of gravity

Height dimension reduced by approx. 

36

%

 (Reduced by  32 mm)

Pulse input type/

Positioning type

Series

 LECSB

Pulse input type

Series

 LECSC

CC-Link

direct input type

Series

 LECSS

SSCNET

#

type

Incremental Type

Absolute Type

AC Servo Motor

Driver

*

1 ISO14644-1

*

2 Federal Standard 209D

*

3  The particle generation characteristics change depending on the suction flow rate. Refer to page 22 for details.

Clean room specification/11-LEJS 

Lead:  24 mm (LEJS40), 30 mm (LEJS63)

Clean room specification 

(ISO Class 4)

 and leads added

ISO Class 4

*

1

 (Class 10)

*

2

*

3

New

New

High Rigidity

Slider Type

11-LEJS

Clean Room Specification

Electric Actuator

RoHS

Series

 LEJ

CAT.ES100-104C

Summary of Contents for 11-LEJS Series

Page 1: ...avity Height dimension reduced by approx 36 Reduced by 32 mm Pulse input type Positioning type Series LECSB Pulse input type Series LECSC CC Link direct input type Series LECSS SSCNET type Incremental...

Page 2: ...Equipped with seal bands as standard Covers the guide ball screw and belt Prevents grease from splashing and external foreign matter from entering AC Servo Motor Table height Motor height Motor Workpi...

Page 3: ...e belt drive actuator cannot be used vertically for applications Electric Actuator High Rigidity Slider Type Solid state auto switch can be mounted For checking the limit and intermediate signal Switc...

Page 4: ...Series LEJ Compatible motor 100 200 VAC Control method Application Function Compatible option 100 W 200 W Note 1 Positioning Pulse Network direct input Note 2 Synchronous Setup software LEC MR SETUP22...

Page 5: ...ustment One touch adjustment button Display the monitor parameter and alarm Display Set parameters and monitor display etc with push buttons Settings Display the monitor parameter and alarm Display Se...

Page 6: ...guratorTM Part no LEC MR SETUP221 Order USB cable Part no LEC MR J3USB separately to use this software USB cable Part no LEC MR J3USB Option Motor cable Lock cable Electric actuator High rigidity slid...

Page 7: ...der compatible Series LECSS SSCNET type Page 56 Page 56 Page 56 Page 56 Page 56 Page 56 Page 57 Page 57 Motor cable Lock cable Encoder cable USB cable Part no LEC MR J3USB Page 57 Page 57 RS 422 commu...

Page 8: ...vo Motor CAT E102 Step Motor Servo 24 VDC CAT ES100 98 CAT ES100 104 Step Motor Servo 24 VDC CAT E102 Size Max work load kg Stroke mm 25 10 Up to 2000 32 20 Up to 2000 Size Max work load kg Stroke mm...

Page 9: ...Dust Drip proof compatible Dust Drip proof compatible Dust Drip proof compatible CAT E102 Step Motor Servo 24 VDC CAT E102 Step Motor Servo 24 VDC CAT E102 Step Motor Servo 24 VDC Servo Motor 24 VDC...

Page 10: ...ng force N Stroke diameter mm Basic Compact 10 5 5 3 5 4 20 22 17 6 32 90 8 40 130 12 Size Max gripping force N Stroke both sides mm 10 7 16 32 20 28 24 48 32 120 32 64 40 180 40 80 Size Max gripping...

Page 11: ...ive Series 11 LEJS Particle Generation Characteristics Page 21 How to Order Page 30 Specifications Page 31 Dimensions Page 32 Electric Actuator High Rigidity Slider Type Belt Drive Series LEJB Model S...

Page 12: ...mended T2 can be found from the following equation T1 and T3 can be obtained by the following equation The acceleration and deceleration values have upper limits depending on the workpiece mass and th...

Page 13: ...LEJS63 B Lead 30 LEJS63 H Area where the regeneration option is required B 0 500 1000 1500 2000 0 5 10 15 20 Work load kg Speed mm s A Area where the regeneration option is required If the stroke exc...

Page 14: ...cceleration Deceleration 5000 mm s2 Acceleration Deceleration 10000 mm s2 Acceleration Deceleration 20000 mm s2 Cycle time s Stroke mm 0 1000 200 400 600 800 0 0 0 5 1 0 1 5 2 0 Cycle time s Stroke mm...

Page 15: ...ime s Stroke mm 0 3000 500 1000 1500 2000 2500 0 0 0 5 1 0 1 5 2 0 Acceleration Deceleration 5000 mm s2 Acceleration Deceleration 10000 mm s2 Acceleration Deceleration 20000 mm s2 Cycle Time Graph Gui...

Page 16: ...100 Duty ratio 75 Duty ratio 50 0 5000 10000 15000 20000 0 10 20 30 40 Work load kg Acceleration Deceleration mm s 2 Duty ratio 100 Duty ratio 50 Duty ratio 25 Duty ratio 75 0 5000 10000 15000 20000 0...

Page 17: ...50 Duty ratio 100 Duty ratio 50 Duty ratio 75 0 5000 10000 15000 20000 0 2 5 5 7 5 10 Work load kg Acceleration Deceleration mm s 2 Duty ratio 100 Duty ratio 25 Duty ratio 75 Duty ratio 50 0 5000 1000...

Page 18: ...atio 50 Duty ratio 100 Duty ratio 50 Duty ratio 75 0 5000 10000 15000 20000 0 5 10 15 20 25 30 Work load kg Acceleration Deceleration mm s 2 The value of 50 or less is the same as duty ratio 50 Duty r...

Page 19: ...m 0 200 400 600 800 1 000 0 10 5 15 20 30 25 Work load kg L4 mm m Me L5 0 200 400 600 800 1 000 0 10 20 30 50 40 Work load kg L5 mm 0 200 400 600 800 1 000 0 20 40 60 80 Work load kg L5 mm 0 200 400 6...

Page 20: ...of gravity of the workpiece overhangs in one direction When the center of gravity of the workpiece overhangs in two directions refer to the Electric Actuator Selection Software for confirmation http...

Page 21: ...ble Displacement Reference Value Note Traveling parallelism does not include the mounting surface accuracy Note This displacement is measured when a 15 mm aluminum plate is mounted and fixed on the ta...

Page 22: ...of particles contained in 141 5 L ANR of air Note 2 Actuator 1 million cycles Note 3 The particle generation characteristics Page 22 provide a guide for selection but is not guaranteed Test Method Ex...

Page 23: ...in ANR 20 L min ANR 30 L min ANR ISO Class 7 Class 10000 ISO Class 6 Class 1000 ISO Class 4 Class 10 ISO Class 5 Class 100 ISO Class 8 Class 100000 0 L min ANR 50 L min ANR 70 L min ANR ISO Class 7 Cl...

Page 24: ...23...

Page 25: ...Page 25 Series LECS AC Servo Motor Driver Series LEJB Belt Drive Series LEJS Ball Screw Drive Series 11 LEJS Page 30 Clean Room Specification AC Servo Motor Page 34 Page 44 24...

Page 26: ...ply voltage V Nil Without driver A1 LECSA1 S 100 to 120 A2 LECSA2 S 200 to 230 B1 LECSB1 S 100 to 120 B2 LECSB2 S 200 to 230 C1 LECSC1 S 100 to 120 C2 LECSC2 S 200 to 230 S1 LECSS1 S 100 to 120 S2 LEC...

Page 27: ...y range RH 90 or less No condensation Regeneration option May be required depending on speed and work load Refer to page 56 Electric specifications Motor output W Size mm 100 40 200 60 Motor type AC s...

Page 28: ...l band Stainless steel 20 Bearing 21 Bearing 22 Nut fixing pin Carbon steel 23 Magnet No Description Material Note 1 Body Aluminum alloy Anodized 2 Ball screw assembly 3 Linear guide assembly 4 Table...

Page 29: ...1 Distance within which the table can move when it returns to origin Make sure a workpiece mounted on the table does not interfere with the workpieces and facilities around the table Note 2 The Z phas...

Page 30: ...can move when it returns to origin Make sure a workpiece mounted on the table does not interfere with the workpieces and facilities around the table Note 2 The Z phase first detecting position from t...

Page 31: ...e motor with lock option is selected 8 Standard cable entry direction is A Axis side o Driver type 6 Compatible drivers Power supply voltage V Nil Without driver A1 LECSA1 S 100 to 120 A2 LECSA2 S 200...

Page 32: ...er 0 3 Absolute encoder Model 11 LEJS63 Stroke mm 300 400 500 600 700 800 900 1000 1200 1500 Product weight kg 11 4 12 7 13 9 15 2 16 4 17 7 18 9 20 1 22 6 26 4 Additional weight with lock kg 0 4 Incr...

Page 33: ...400 723 5 763 5 406 460 8 2 400 80 11 LEJS40S 500 823 5 863 5 506 560 8 2 400 180 11 LEJS40S 600 923 5 963 5 606 660 10 3 600 80 11 LEJS40S 700 1023 5 1063 5 706 760 10 3 600 180 11 LEJS40S 800 1123...

Page 34: ...e Note 2 When mounting the actuator using the body mounting reference plane use a pin Set the height of the pin to be 5 mm or more because of chamfering Recommended height 6 mm Note 3 This drawing sho...

Page 35: ...ncoder 100 40 LECSA S1 S3 AC servo motor Incremental encoder 200 63 LECSA S3 S6 AC servo motor Absolute encoder 100 40 LECSB S5 LECSC S5 LECSS S5 S7 AC servo motor Absolute encoder 200 63 LECSB S7 LEC...

Page 36: ...urable stroke range 300 to 3000 mm LEJB40 63 AC Servo Motor Model LEJB40S2 6 LEJB63S3 7 Actuator specifications Stroke mm Note 1 200 300 400 500 600 700 800 900 1000 1200 1500 2000 300 400 500 600 700...

Page 37: ...y Anodized 30 Motor plate Carbon steel 31 Belt 32 Motor 33 Grommet NBR 34 Dust seal band Stainless steel 35 Bearing 36 Bearing 37 Stopper pin Stainless steel 38 Magnet No Description Material Note 1 B...

Page 38: ...he table can move when it returns to origin Make sure a workpiece mounted on the table does not interfere with the workpieces and facilities around the table Note 2 The Z phase first detecting positio...

Page 39: ...1 Distance within which the table can move when it returns to origin Make sure a workpiece mounted on the table does not interfere with the workpieces and facilities around the table Note 2 The Z pha...

Page 40: ...0 15 A C B Table center When mounting the auto switches they should be inserted into the actuator s auto switches mounting groove from the direction shown in the drawing on the below Once in the moun...

Page 41: ......

Page 42: ...SMC website for the details about products conforming to the international standards D M9l D M9lV With indicator light Auto switch model D M9N D M9NV D M9P D M9PV D M9B D M9BV Electrical entry In line...

Page 43: ...C website for the details about products conforming to the international standards PLC Programmable Logic Controller D M9lW D M9lWV With indicator light Auto switch model D M9NW D M9NWV D M9PW D M9PWV...

Page 44: ...st the stroke end of the actuator Please check these points before use If the table collides against the stroke end of the actuator the guide belt or internal stopper can be broken This may lead to ab...

Page 45: ...flaw and cable joint 3 Vibration Noise Items for internal check 1 Lubricant condition on moving parts For lubrication use lithium grease No 2 2 Loose or mechanical play in fixed parts or fixing screws...

Page 46: ...43...

Page 47: ...ver Series LECS Pulse Input Type Positioning Type Pulse Input Type Series LECSA Incremental Type Series LECSB Absolute Type CC Link Direct Input Type Series LECSC Absolute Type Series LECSS Absolute T...

Page 48: ...6 outputs Position data speed data setting and operation start stop Positioning by up to 255 point tables when 2 stations occupied Up to 32 drivers connectable when 2 stations occupied with CC Link c...

Page 49: ...r connector CN3 RS 422 communication connector CN4 Battery connector CN5 USB communication connector CN6 Analog monitor connector CNP1 Main circuit power supply connector CNP2 Control circuit power su...

Page 50: ...cal cable CN1B Rear axis connector for SSCNET optical cable CN2 Encoder connector CN3 I O signal connector CN4 Battery connector CN5 USB communication connector CNP1 Main circuit power supply connecto...

Page 51: ...00 VDC Weight g 600 700 Model LECSB1 S5 LECSB1 S7 LECSB2 S5 LECSB2 S7 LECSB2 S8 Compatible motor capacity W 100 200 100 200 400 Compatible encoder Absolute 18 bit encoder Resolution 262144 p rev Main...

Page 52: ...tion V Single phase 85 to 132 VAC Three phase 170 to 253 VAC Single phase 170 to 253 VAC Rated current A 3 0 5 0 0 9 1 5 2 6 Control power supply Control power supply voltage V Single phase 100 to 120...

Page 53: ...circuit power supply 0 V 0 V side of the control circuit power supply 24 VDC supplied to the driver Terminal name Function Details Protective earth PE Should be grounded by connecting the servo motor...

Page 54: ...ple Terminalname Function Details P Regeneration option Connect between P and D Connected at time of shipping If regeneration option is required for Model Selection connect to this terminal C D L11 Co...

Page 55: ...1 s protective earth PE terminal marked to the control panel s protective earth PE Note 2 For interface use supply 24 VDC 10 200 mA using an external source 200 mA is the value when all I O command si...

Page 56: ...ector Control common Control common RA1 RA2 RA3 2 m or less 1 LG 3 MO1 2 MO2 Analog monitor 2 Analog monitor 1 10 VDC 10 VDC RA4 PULSE R PULSE R 14 13 12 11 15 16 10 9 17 18 RD 49 Note 4 Note 4 Contro...

Page 57: ...fferential line driver B phase pulse encoder Differential line driver Control common RA1 RA2 RA3 Note 2 24 VDC Power supply CN1 CC Link Control Signal Wiring Example LECSC Note 1 For preventing electr...

Page 58: ...1 2 RA2 RA3 2 m or less CN1A CN1B CN1A CN1B CN1A CN1B CN1A CN1B RA1 LECSS Axis 3 SW1 SW2 1 2 LECSS Axis n SW1 SW2 1 2 24 VDC Note 2 Note 1 Control Signal Wiring Example LECSS Series LECS Note 1 For pr...

Page 59: ...ation option type LE CSNB LE CSNS Regeneration option LECS common LEC MR RB LE CSN A Dimensions mm Confirm regeneration option to be used in Model Selection MR RB manufactured by Mitsubishi Electric L...

Page 60: ...efore using a PC for setting LECSA point table method program method or LECSC point table No input upgrade to version C5 Japanese version version C4 English version Refer to Mitsubishi Electric s webs...

Page 61: ...5 minutes after power off when performing installation wiring and maintenance Otherwise electric shock fire or injury can result 9 Static electricity may cause a malfunction or damage the driver Do n...

Page 62: ...measures to prevent surges from lightning Ground the surge absorber for lightning separately from the grounding of the driver and its peripheral devices 1 The driver will be damaged if a commercial p...

Page 63: ...ning Limited warranty and Disclaimer Compliance Requirements The product used is subject to the following Limited warranty and Disclaimer and Compliance Requirements Read and accept them before using...

Reviews: