background image

 

If you have any questions,we’d be happy to help: 

smb Seilspielgeräte GmbH Berlin in Hoppegarten 

Fon. 

+49 (0) 3342 50837-20 

[email protected] 

Technikerstraße 6/8 

Fax.  

+49 (0) 3342 50837-80 

www.smb.berlin 

DE-15366 Hoppegarten 

09.04.2020 

Page 1 von 9 

 
 
 
 
 

Contents 

 

1

 

Mounting instructions 

1.1

 

General information and specs 

Page 02 

1.2

 

Ground properties 

Page 02 

1.3

 

Mounting tool 

Page 02 

1.4

 

Mounting 

Page 03 

 
 

2

 

Maintenance instructions 

2.1

 

Maintenance intervals 

Page

 

04 

 

2.2

 

Removal and re-mounting of the jump mat 

Page

 

05 

2.3

 

Special characteristics 

Page

 

07 

2.4

 

flashtramp® 

Page

 

08 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Technical information – TRAMPOLINE S  

Fig. 1 – 

Symbolic illustration of Trampoline S with a multicolor jump mat

 

tuev-sued.de/ps-zert

 

Summary of Contents for TRAMPOLINE S

Page 1: ...ts 1 Mounting instructions 1 1 General information and specs Page 02 1 2 Ground properties Page 02 1 3 Mounting tool Page 02 1 4 Mounting Page 03 2 Maintenance instructions 2 1 Maintenance intervals Page 04 2 2 Removal and re mounting of the jump mat Page 05 2 3 Special characteristics Page 07 2 4 flashtramp Page 08 Technical information TRAMPOLINE S Fig 1 Symbolic illustration of Trampoline S wit...

Page 2: ...nner edge of the rubber plate Free space 3 50 m height above jumping area Max free fall height 0 90 m Weight of heaviest individual component 130 kg total weight of trampoline without packaging Age range 3 years and upwards Number of users 1 person 1 2 Ground properties Shock absorbent ground compliant with DIN EN 1176 1 must be provided over the entire impact area draft plan We recommend syntheti...

Page 3: ...g if the soil is clay based then a drainage layer should be installed There are a total of four drill holes sealed with stoppers on the sides of the frame The bearing irons supplied are guided through these to transport the trampoline and position it in the excavated pit please seal the drill holes again afterwards Care must be taken to ensure that the frame is positioned squarely and does not til...

Page 4: ...can be made in this regard We reccomend that an assessment of the maintenance interval be determined based on experience on site Operational inspection every six months Check the play equipment for general damage or signs of wear and tear Check the inside of the trampoline for dirt see routine visual inspection Check the condition of the jump mat spring suspension fittings and the fall protection ...

Page 5: ...ok notch of the spring and slowly pulled using the rope attached to it Once the appropriate extension of the spring has been achieved the fastening links chain links that are secured on two sides of the jump mat fall independently downwards These fastening links thimbles on the other two sides of the jump mat must be pushed out downwards once the springs have been extended These do not fall indepe...

Page 6: ...uestions we d be happy to help smb Seilspielgeräte GmbH Berlin in Hoppegarten Fon 49 0 3342 50837 20 info smb berlin Technikerstraße 6 8 Fax 49 0 3342 50837 80 www smb berlin DE 15366 Hoppegarten 09 04 2020 Page 6 von 9 Fig 4 Re mounting of the jump mat ...

Page 7: ...werful forces arising from friction and bending cycles while the equipment is being used The stress on the material of the parts in question is therefore commensurately high and signs of wear and tear can appear over the equipment s period of use smb trampolines are built so that all of the parts affected can be exchanged as required and the equipment can continue to be used for many years During ...

Page 8: ...s make the flashtramp lighting unit visibly light up The power required is generated simply by the user jumping Assembly maintenance climate protection sustainability is important to us With the flashtramp lighting unit you have acquired a high quality electronic component that is already integrated into the jump mat before delivery which means that no additional installation work is required The ...

Page 9: ...020 Page 9 von 9 However it is possible that a lighting unit does not work as it should or fails completely In this case it must be replaced and the faulty unit disposed of correctly or recycled To ensure this flashtramp lighting units are WEEE cerified Fig 7 flashtramp lighting unit Too much of a hussle No problem Simply send us the defective lighting unit back and we will take care of the profes...

Reviews: