Other mute beam disparity options can be selected via DIP switch modes 2, 3 and
4 in the Learn mode. E.g. Mode 4 for Press brake machine applications.
Mute Time Out Period (B)
This is the maximum pre-determined time that the safety light curtain will remain
in a muted condition. The default is 15 minutes or it can be changed to infinite via
DIP switch 3 in the Direct Settings mode. Use of the infinite mute time out must
be subject to the detailed risk assessment.
Mute Delay Off Time (C)
This is the pre-determined time (2 second default) that the safety light curtain will
remain in a muted condition following de-activation of one or both of the mute
input signals. Other mute delay off options can be selected in the Learn mode.
The T4 (053B) series is supplied with the following default settings:
Mute Input Disparity Time (A)
2 seconds
Mute Time Out Period (B)
15 minutes
Mute Delay Off Time (C)
2 seconds
Partial Muting
Off
Fixed Beam Blanking
Off
Floating Beam Blanking
Off